Weidmüller’s ‘u-remote’ represents a new, modularly designed remote I/O system distinguished by plug-in connection, high component density and high levels of efficiency and productivity. The integrated web server simplifies start-up and aids maintenance workers. Distinctive features include lean planning, simple installation, fast start-up and reduced downtime.
As installation can be carried out without the need for tools and the cabling is pre-assembled, a reliable installation can be conducted faster in the switch cabinet as well as on the machine and system. The single row connection level facilitates ease of wiring, installation and service. The plug-in connection level allows for the quick and safe connection of sensors and actuators with pre-assembled cables while simultaneously minimising the error rate in the system wiring.
Thanks to the slim modular design and a low number of power-feed modules, switch cabinets with ‘u-remote’ can be designed significantly smaller while increasing flexibility in their layout. A component can be replaced load-free during operation i.e. without having to interrupt the bus connection and disconnect the power supply.
The ‘u-remote’ system has two features that set it apart in class: First, it separates the supply for inputs and outputs with two 10 A current paths capable of handling heavy loads – this reduces the number of power-feed modules needed and at the same time saves space as well as planning and maintenance effort. Second, it has an internal supply path capable of handling heavy loads, which allows 64 modules to be operated with just one power supply on the coupler.
The ‘u-remote’ I/O system has freely selectable sensor connection options (2, 3 and 4 conductor technology) and can be operated in a temperature range from -20 to 60°C. The high-speed system bus provides impressive electronic performance and works with as many as 256 DI/DOs in 20 μs. LEDs on the module, directly positioned on the conductor connection, are extremely helpful for reading statuses and diagnostics.
Network-capable remote relay system with flexible channel assignment Phoenix Contact
PLCs, DCSs & Controllers
Phoenix Contact has launched a modular PLC-Interface Ethernet Gateway remote relay system with up to 56 configurable I/O channels, multi-protocol support including Profinet Class C and S2 redundancy, and compatibility with established controller software for straightforward network integration.
Read more...Seven checks before replacing an obsolete industrial control component
PLCs, DCSs & Controllers
An obsolete control component rarely fails in isolation. Before ordering an exact spare, manufacturer successor or engineered alternative, maintenance and procurement teams should work through seven checks to define the problem properly and avoid a costly mismatch.
Read more...Loop signature Part 2-6
PLCs, DCSs & Controllers
This instalment of the Loop Signature series introduces frequency plot theory as a foundation for understanding process dynamics, explaining Bode plots, dynamic gain, phase lag and their relationship to control loop tuning.
Read more...The rise of software-defined brownfield automation Schneider Electric South Africa
PLCs, DCSs & Controllers
Schneider Electric’s EcoStruxure Automation Expert is enabling brownfield operators to modernise incrementally, decoupling control logic from hardware to bridge legacy equipment and future-ready operations without disrupting production.
Read more...Upgrading alarm systems for critical industries Omniflex Remote Monitoring Specialists
PLCs, DCSs & Controllers
Omniflex’s OMNI16R alarm annunciator platform provides a direct replacement for legacy CSA systems such as MPAS 90 and SA9100, enabling operators in oil and gas, nuclear and power generation to modernise alarm infrastructure without sacrificing the clarity required for safe operations.
Read more...How DCS can step off the hardware obsolescence treadmill Schneider Electric South Africa
PLCs, DCSs & Controllers
Schneider Electric argues that virtualising DCS environments breaks the cycle of hardware obsolescence, giving plant operators a smarter path to lifecycle modernisation without production disruption.
Read more...Loop signature Part 2-6
PLCs, DCSs & Controllers
The Loop Signature series turns to frequency plot theory, explaining Bode open-loop plots and how dynamic gain, phase lag and crossover frequency can be extracted from test data to inform more accurate control loop tuning.
Read more...PC-based control in surgery Beckhoff Automation
Editor's Choice PLCs, DCSs & Controllers
Researchers at the University of Basel are using Beckhoff PC-based control technology to develop a miniature laser robot for minimally invasive bone surgery.
Read more...How the DCS can step off the hardware obsolescence treadmill Schneider Electric South Africa
PLCs, DCSs & Controllers
Ageing servers and unsupported operating systems are quietly eroding the stability of process plants that rely on distributed control systems. Kobus Vermeulen of Schneider Electric explains how virtualising the DCS environment can break the hardware obsolescence cycle without disrupting operations.
While every effort has been made to ensure the accuracy of the information contained herein, the publisher and its agents cannot be held responsible for any errors contained, or any loss incurred as a result. Articles published do not necessarily reflect the views of the publishers. The editor reserves the right to alter or cut copy. Articles submitted are deemed to have been cleared for publication. Advertisements and company contact details are published as provided by the advertiser. Technews Publishing (Pty) Ltd cannot be held responsible for the accuracy or veracity of supplied material.