The new generation of the TX700 HMI/PLC series can control and visualise even more complex processes and applications than before. Thanks to several interfaces and an integrated OPC UA server, this device generation is well set for the future of automation. Particularly, it enables customers looking for a versatile controller suitable for use in different applications to keep their stock at manageable levels. Users requiring simple display devices without a control function will also find a solution in the series.
TX207
A combination of the high-quality plastic housing of the TX100 series and the new powerful hardware platform of the premium HMI/PLC devices of the TX700 series, the resistive touch screen of the device is 7’’ diagonal. The TX207 has two RS-232 and two RS-485, as well as two CAN interfaces. In addition, two USB ports are available. Programming is done with Codesys3.5 SP12. Two options are available for creating the visualisation. On the one hand the Codesys TargetVisu can be used, and on the other, the visualisation editor TX VisuPro. It has sufficient memory and computing power and the operating system is real-time Linux, instead of Windows Embedded.
TX100
This product line includes three new devices with 4”, 7” and 10” screen diagonals and a resistive touch. The display has an Ethernet interface, a serial interface (RS-232, RS-422 or RS-485) and a USB port. The TX100 devices are pure HMIs without control function. The graphical user interface is therefore not created with Codesys, but exclusively with the visualisation editor. TX VisuPro is a modern software package for the development of user-friendly graphical user interfaces. It supports various drivers, which also allow communication with controllers such as Siemens, Beckhoff, Rockwell, Schneider and many other systems.
Loop signature Part 2-6
PLCs, DCSs & Controllers
This instalment of the Loop Signature series introduces frequency plot theory as a foundation for understanding process dynamics, explaining Bode plots, dynamic gain, phase lag and their relationship to control loop tuning.
Read more...The rise of software-defined brownfield automation Schneider Electric South Africa
PLCs, DCSs & Controllers
Schneider Electric’s EcoStruxure Automation Expert is enabling brownfield operators to modernise incrementally, decoupling control logic from hardware to bridge legacy equipment and future-ready operations without disrupting production.
Read more...Upgrading alarm systems for critical industries Omniflex Remote Monitoring Specialists
PLCs, DCSs & Controllers
Omniflex’s OMNI16R alarm annunciator platform provides a direct replacement for legacy CSA systems such as MPAS 90 and SA9100, enabling operators in oil and gas, nuclear and power generation to modernise alarm infrastructure without sacrificing the clarity required for safe operations.
Read more...How DCS can step off the hardware obsolescence treadmill Schneider Electric South Africa
PLCs, DCSs & Controllers
Schneider Electric argues that virtualising DCS environments breaks the cycle of hardware obsolescence, giving plant operators a smarter path to lifecycle modernisation without production disruption.
Read more...Loop signature Part 2-6
PLCs, DCSs & Controllers
The Loop Signature series turns to frequency plot theory, explaining Bode open-loop plots and how dynamic gain, phase lag and crossover frequency can be extracted from test data to inform more accurate control loop tuning.
Read more...PC-based control in surgery Beckhoff Automation
Editor's Choice PLCs, DCSs & Controllers
Researchers at the University of Basel are using Beckhoff PC-based control technology to develop a miniature laser robot for minimally invasive bone surgery.
Read more...How the DCS can step off the hardware obsolescence treadmill Schneider Electric South Africa
PLCs, DCSs & Controllers
Ageing servers and unsupported operating systems are quietly eroding the stability of process plants that rely on distributed control systems. Kobus Vermeulen of Schneider Electric explains how virtualising the DCS environment can break the hardware obsolescence cycle without disrupting operations.
Read more...Centralised control rooms where growth is elastic, not physical Schneider Electric South Africa
PLCs, DCSs & Controllers
Modernised control rooms feature distributed control system architecture consolidated into centralised compute environments. replacing traditional PCs with thin clients.
While every effort has been made to ensure the accuracy of the information contained herein, the publisher and its agents cannot be held responsible for any errors contained, or any loss incurred as a result. Articles published do not necessarily reflect the views of the publishers. The editor reserves the right to alter or cut copy. Articles submitted are deemed to have been cleared for publication. Advertisements and company contact details are published as provided by the advertiser. Technews Publishing (Pty) Ltd cannot be held responsible for the accuracy or veracity of supplied material.