System Integration & Control Systems Design


Saryx helps Transnet achieve ROI through scada modernisation

November 2019 System Integration & Control Systems Design

Saryx Engineering has set the bar high in terms of scada modernisation and standardisation. So much so that the company won ‘Best Control & Information Implementation’ in recognition of a project with client Transnet Freight Rail in Saldanha, earlier this year at the IS3 X-Change Conference.


Left to right: Steven Jeffery (IS3), Roland Verwey (Saryx Engineering), Phillip Nel (Transnet Freight and Rail) and Mandhla Matshazi (IS3) at the awards ceremony.

The task: to replace Transnet’s GE iFix system in parallel with System Platform without introducing downtime or interfering with operational performance.

To put things into perspective, the Saldanha-Sishen Railway is 861 km in length, seeing approximately 38 trains per week. The length of each train is 3,9 km, with 342 wagons, and five to eight locomotives, making them among the longest freight trains in the world.

With the enormity of such a loading operation, one of the main requirements for this project was to achieve zero downtime while the upgrade project took place. In addition, the learning curve from the old system to the new needed to be minimal in terms of operator training.

Key aspects of the project included:

• Move from RS-232 serial technology to Modbus TCP.

• Replace current desktop PC with industrial server technology.

• Move all scada views to terminal server technology.

• Achieve high system availability.

How did System Platform assist?

• Moved to object-based design for standardisation of graphics and tags.

• ISA 95 was implemented to the system which manages the object configuration and alarming resolution.

• Wonderware Insight implementation improved data analysis for engineering staff.

• System Platform is virtual server compliant.

The most significant advantage established from the object-oriented design was that it exposed inconsistent or irregular field values, which varied from site to site. This was very difficult to pick up in the old tag-based system design.

The old system had reached end of life

The old system shared the same computer as the CS90 system. The issue was that the CS90 had the capability to upgrade to a newer Windows version, but the iFix did not. The iFix had operational interference on the CS90 system, and vice versa, because they shared the same client computers with multiple screen cards. In-house support and system knowledge had been lost due to staff retiring.

Saryx installed a temporary Motorola interface to mirror the data to both old and new system. With this, Saryx could compare the old and new status to ensure all signals were correct. The iFix system could now be decommissioned without causing downtime. A rollback option was available if required to minimise operational impact and the operational staff had a sneak preview of the system before it went live. To their surprise, not much had changed in terms of screen navigation. Because of this, the engineering staff developed confidence in the new system while it is working in parallel with the old.

Network design was simple as follows:

• Control network with redundant terminal and data acquisition servers.

• Scada network linked to the terminal client.

• Motorola network separate from the scada network to ensure the least amount of collision domains.

• Insight installed.

• Skelta BPM for automation of data to CASDAM system for Transnet.

• Alarm Advisor which assists the maintenance staff with the alarms.

Prior to the upgrade, the systems had a generator overview, loop status, generator status, and an operator overview. Post upgrade, in addition to the above, a template was used to get standards across all screens in the HMI. The object graphics are embedded instead of redrawn, and grid snapping ensures that all graphics align correctly.

Operators and managers can now interrogate the alarms and events from the scada, while managers have an overview into the system performance. Wonderware Insight gives managers the ability to ‘google’ for the tags they need analytics on, instead of using the filter and navigating options in the query and trend tools. After adding the historians, easy clicks transform how the data is viewed. In addition, the scada now offers ‘Flight of Sight’ graphics, which is important for operational staff.




Share this article:
Share via emailShare via LinkedInPrint this page

Further reading:

Turning system integrators into trusted technology partners
Schneider Electric South Africa IT in Manufacturing System Integration & Control Systems Design
Schneider Electric’s Alliance Partner Programme is repositioning system integrators from hardware suppliers into lifecycle-value partners. Oriel Soupen explains the competency framework, certification model and real-world results that are already helping African system integrators win higher-value, longer-term engagements.

Read more...
When digital twins move from concept to critical tool
IT in Manufacturing System Integration & Control Systems Design Maintenance, Test & Measurement, Calibration
Digital twins are moving out of the lab and onto the mine, the factory floor and the transport network where they predict failures before they happen. Amritesh Anand looks at where they earn their keep, the data and integration work behind them, and the security questions every organisation should ask before switching one on.

Read more...
Best practices for managing the MRO supply chain in Africa
RS South Africa System Integration & Control Systems Design
RS South Africa outlines how strong data governance and digital tools can turn maintenance, repair and operations procurement into a strategic advantage across Africa.

Read more...
Containerised Solar Solution Accelerates Delivery of Riverside 3 MW Power Plant
Proconics System Integration & Control Systems Design
Proconics was engaged by NewFields to deliver the electrical integration solution for the Riverside 3 MW Solar Power Plant in Zimbabwe. The project required a compact, modular approach that could simplify deployment, minimise site works, and support rapid commissioning in a remote location.

Read more...
Modern Energy Metering Solution Enhances Reliability and Reporting for Major Power Utility
SAM Systems Automation & Management System Integration & Control Systems Design
This project involved the implementation of a modern energy metering system for a major power utility operating within the industrial automation and energy management sector. The objective was to improve the reliability, accessibility, and accuracy of energy data while simplifying infrastructure and reducing system complexity.

Read more...
PCS Global
PCS Global System Integration & Control Systems Design
PCS Global led a digital infrastructure initiative in a southern African data centre setting, aiming to merge several essential operational systems into one cohesive platform. The objective was to break down silos, enable real-time decisions, and ensure seamless operation in a mission-critical environment.

Read more...
Seamless migration from ET 200M to ET 200SP HA for future-ready automation
Moore Process Controls System Integration & Control Systems Design
Moore Process Controls undertook a modernisation initiative spanning the mining, petrochemical, and oil & gas sectors. This project involved upgrading legacy Siemens ET200M I/O systems to the advanced ET200SP HA platform.

Read more...
Proconics Modernises Refinery Tank Automation with Compliance-Focused, Brownfield Upgrades
Proconics System Integration & Control Systems Design
Project & Industry Proconics was engaged to modernise automation and SCADA systems across a refinery tank farm. The project involved complex brownfield integration, aligning new automation with existing ...

Read more...
Project & Industry
System Integration & Control Systems Design
Project: Upgrading essential automation and SCADA systems at a coal mine.    Outcome: A modern, stable automation and SCADA environment with reduced technical debt and easier support, ready for expansion. ...

Read more...
Major digital transformation project for Isuzu Motors
System Integration & Control Systems Design
Isuzu Motors South Africa, in partnership with NoMuda and S4 Integration, has kicked off a major two-year digital transformation project to modernise its production environment.

Read more...









While every effort has been made to ensure the accuracy of the information contained herein, the publisher and its agents cannot be held responsible for any errors contained, or any loss incurred as a result. Articles published do not necessarily reflect the views of the publishers. The editor reserves the right to alter or cut copy. Articles submitted are deemed to have been cleared for publication. Advertisements and company contact details are published as provided by the advertiser. Technews Publishing (Pty) Ltd cannot be held responsible for the accuracy or veracity of supplied material.




© Technews Publishing (Pty) Ltd | All Rights Reserved