In addition to BACnet/IP, Beckhoff now also supports BACnet MS/TP (Master Slave/Token Passing) with the EL6861 EtherCAT Terminal. This serial interface can be used directly to control and monitor BACnet-compatible field devices, such as pumps, drives, frequency converters or similar, as sub-bus systems, without the need for additional gateways or routers. Up to 64 devices with RS-485 low power transceivers can be connected.
In addition, several terminals can be operated in parallel to scale the number of MS/TP channels that can be supported.
Using the 1-channel BACnet MS/TP interface, hardware and engineering costs can be significantly reduced since configuration is performed centrally in the TwinCAT System Manager and external devices, such as routers or gateways, do not need to be connected. Combined with the BACnet MS/TP driver integrated within TwinCAT automation software, the terminal implements the BACnet protocol in compliance with Revision 12. The terminal can also be used locally without routing to the BACnet/IP network.
The RS-485 interface guarantees high interference immunity through electrically isolated signal transmission. The EL6861 provides 1 x 5 VDC at 20 mA (electrically isolated, short-circuit-proof) from the E-bus supply for use with the bias resistors (network bias).
Upgrading alarm systems for critical industries Omniflex Remote Monitoring Specialists
PLCs, DCSs & Controllers
Omniflex’s OMNI16R alarm annunciator platform provides a direct replacement for legacy CSA systems such as MPAS 90 and SA9100, enabling operators in oil and gas, nuclear and power generation to modernise alarm infrastructure without sacrificing the clarity required for safe operations.
Read more...XPlanar aids innovation in laser processing Beckhoff Automation
Fieldbus & Industrial Networking
Aalborg University is among the first in the world to test Beckhoff’s XPlanar intelligent transport system in advanced laser processes, opening the door to faster, tool-free production of metal parts.
Read more...How DCS can step off the hardware obsolescence treadmill Schneider Electric South Africa
PLCs, DCSs & Controllers
Schneider Electric argues that virtualising DCS environments breaks the cycle of hardware obsolescence, giving plant operators a smarter path to lifecycle modernisation without production disruption.
Read more...Loop signature Part 2-6
PLCs, DCSs & Controllers
The Loop Signature series turns to frequency plot theory, explaining Bode open-loop plots and how dynamic gain, phase lag and crossover frequency can be extracted from test data to inform more accurate control loop tuning.
Read more...Dynamic control of industrial solar plants and energy storage systems Beckhoff Automation
Editor's Choice IT in Manufacturing
Spanish group, Power Electronics uses Beckhoff embedded PCs and TwinCAT software to achieve switching times of 110 ms across solar and battery storage systems, enabling the delivery of grid support services that command higher energy prices.
Read more...PC-based control in surgery Beckhoff Automation
Editor's Choice PLCs, DCSs & Controllers
Researchers at the University of Basel are using Beckhoff PC-based control technology to develop a miniature laser robot for minimally invasive bone surgery.
Read more...How the DCS can step off the hardware obsolescence treadmill Schneider Electric South Africa
PLCs, DCSs & Controllers
Ageing servers and unsupported operating systems are quietly eroding the stability of process plants that rely on distributed control systems. Kobus Vermeulen of Schneider Electric explains how virtualising the DCS environment can break the hardware obsolescence cycle without disrupting operations.
Read more...Test bench for temperature calibrating power semiconductors Beckhoff Automation
Temperature Measurement
Precise temperature characteristics are essential for performing power cycling tests on power semiconductors. Infineon Technologies determines these characteristic curves on a test bench using PC-based control. As a result, calibration has become more precise and the efficiency of the entire test laboratory has increased significantly.
Read more...XTS for highly efficient end-of-line packaging of beverage bottles Beckhoff Automation
Editor's Choice
Italian machine builder Clevertech used Beckhoff’s XTS linear transport system to help a Dutch distillery double its bottle packaging throughput to 225 bottles per minute while cutting format changeover times from 30 minutes to just seven.
While every effort has been made to ensure the accuracy of the information contained herein, the publisher and its agents cannot be held responsible for any errors contained, or any loss incurred as a result. Articles published do not necessarily reflect the views of the publishers. The editor reserves the right to alter or cut copy. Articles submitted are deemed to have been cleared for publication. Advertisements and company contact details are published as provided by the advertiser. Technews Publishing (Pty) Ltd cannot be held responsible for the accuracy or veracity of supplied material.