Analytical Instrumentation & Environmental Monitoring


Focus on combustion and refinery applications

January 2020 Analytical Instrumentation & Environmental Monitoring

Instrotech now offers Keller’s range of intrinsically safe electronic pressure gauges for use in areas subject to gas explosion risks. The type approvals are compliant with the ATEX Explosion Protection Directive regarding explosive gases. The electronic design of these devices is trimmed to minimise energy consumption, so it is also possible to replace the batteries inside areas with explosion risks.

The simplest version, model ECO 1 Ei, offers high resolution and reproducibility for both measuring ranges (-1 to 30 bar and 0 to 300 bar), together with accuracy (typical) of 0,5% FS and an integrated min/max memory. The application range as per the ATEX directive is defined by identification markings Ex ia IIC T5 or T6.

Keller’s type Leo 1 Ei and LEO 2 Ei electronic pressure gauges feature microprocessor-assisted compensation to ensure an extremely narrow total error band (including temperature errors) of 0,2 % FS over the entire range of operating temperatures from 0-50°C. The zero point can be selected freely within the four measuring ranges and an automatic switch-off function guarantees energy efficiency. Both models feature sampling rates of 2 Hz and integrated min/max memories. The special feature of the Leo 1 Ei is its additional memory for peak values. In peak mode, even extremely short-lived peak values for system pressure are registered with a sampling rate of 5000 Hz. For both these pressure gauges, the application range as per the ATEX directive is defined by identification markings Ex ia IIC T5 or T6.

Another version of the Leo type electronic pressure gauge, the Record Ei, is equipped with an integrated data memory to record pressure and temperature progressions in the measuring medium. Outside of areas with explosion risks, the data can be transmitted via an RS-485 interface to a PC for evaluation with the Logger 4.X software. The instrument can register pressures of up to 1000 bar with a total error band of 0,1% FS. With a capacitive sensor, this type is also available for very low measuring ranges starting from 30 mbar. The application range as per the ATEX directive is defined by identification marking Ex ia IIC T4.

Featuring accuracy of up to 0,01% FS, the Lex 1 Ei electronic pressure gauge is a genuine reference and precision measuring instrument that has been specifically equipped with a 5-digit display for calibration and testing purposes. Pressure measurement ranges of between -1 and 1000 bar are available. This device also offers a min/max memory and a digital interface to generate PC protocols. The application range as per the ATEX directive is defined by identification marking Ex ia IIC T6.

Features that are shared by all Keller digital pressure gauges include simple parameterisation and operation with only two buttons, while the pressure display can be shown in various physical units that are freely selectable.


Credit(s)



Share this article:
Share via emailShare via LinkedInPrint this page

Further reading:

Importance of gas analysis in the petrochemical industry
Elemental Analytics Analytical Instrumentation & Environmental Monitoring
Gas analysis plays a critical role in petrochemical operations, supporting process optimisation, product quality and plant safety. As an experienced and expert gas analysis supplier, Elemental Analytics can provide the correct analyser and sample system package to meet individual plant requirements.

Read more...
Fully integrated standalone thunderstorm warning system
Senseca Sensors & Transducers Analytical Instrumentation & Environmental Monitoring
Senseca South Africa has introduced its BTD-1 fully integrated, standalone thunderstorm warning system, which detects lightning by monitoring the background quasi-electrostatic field. The system can generate alerts before the first lightning strike, with a detection raterange of up to 83 km.

Read more...
Environmental monitoring with testo Saveris 1
Analytical Instrumentation & Environmental Monitoring
The testo Saveris 1 environmental monitoring system has been in continuous use since 2010 at Jungbunzlauer, a biotechnology company in Germany, providing seamless temperature and humidity data for audit-ready, GxP-compliant processes across laboratories, warehouses and production areas.

Read more...
Field calibration made easy
Instrotech Maintenance, Test & Measurement, Calibration
Instrotech’s locally designed and manufactured Calog calibrator range feature a rugged IP54-rated housing, backlit display with data logging via SD card, and a lithium-ion battery with approximately eight hours of run time.

Read more...
Groundwater level measurement using LoRa module
Instrotech Level Measurement & Control
Monitoring groundwater levels across large industrial sites is critical. Salzgitter Digital Solution was tasked with developing a fully automated and digital monitoring system using Long Range Wide Area Network technology.

Read more...
Reliability restored through systemic vibration analysis
Wearcheck Analytical Instrumentation & Environmental Monitoring
Condition monitoring specialist, WearCheck uses a variety of testing techniques to enhance reliability in machinery components and prevent failures.

Read more...
Meteorological data logger with up to 32 analogue sensors
Senseca Analytical Instrumentation & Environmental Monitoring
Senseca has introduced its advanced data acquisition system for environmental monitoring, which has a universal data logger for up to 32 analogue, pulse and smart digital sensors.

Read more...
Yokogawa’s free chlorine analyser is gold standard for water treatment utilities
Yokogawa South Africa Analytical Instrumentation & Environmental Monitoring
One of the key factors in ensuring safe drinking water is the accurate monitoring of free chlorine residuals. This is where advanced online analysers, such as Yokogawa’s FC800 free chlorine analyser, are becoming increasingly valuable for water treatment operators and municipal utilities.

Read more...
Cooling tower bleed control
Analytical Instrumentation & Environmental Monitoring
Cooling towers rely on evaporation to remove heat, but this process also concentrates dissolved solids in the system. Left unmanaged, this buildup can lead to scaling, corrosion and fouling, reducing efficiency and increasing maintenance costs.

Read more...
Expanded test laboratory provides polymer users with more information
igus Analytical Instrumentation & Environmental Monitoring
igus has expanded its international testing facilities to accommodate its increasing product portfolio and enable continuous improvement of its product quality.

Read more...









While every effort has been made to ensure the accuracy of the information contained herein, the publisher and its agents cannot be held responsible for any errors contained, or any loss incurred as a result. Articles published do not necessarily reflect the views of the publishers. The editor reserves the right to alter or cut copy. Articles submitted are deemed to have been cleared for publication. Advertisements and company contact details are published as provided by the advertiser. Technews Publishing (Pty) Ltd cannot be held responsible for the accuracy or veracity of supplied material.