Yokogawa releases two new liquid analysis products for monitoring

February 2019 Analytical Instrumentation & Environmental Monitoring

Yokogawa has announced that it has added two new solutions to the Opre analyser family with the development of the FLXA402 4-wire liquid analyser and the SA11 smart adaptor. These two new liquid analysis products will be offered as part of the Sencom 4.0 series. It is expected that they will help to improve the efficiency of calibration and other maintenance tasks, and facilitate the flexible design and operation of liquid analysis data monitoring systems.

Liquid analysers consist of a sensor and a transmitter with a data conversion function, and are used to monitor items such as the quality of raw materials and finished products, and water quality in the wastewater treatment process. They are utilised in a wide range of industries including power, water supply, municipal and industrial wastewater treatment, semiconductors, foods, pharmaceuticals, iron and steel, pulp and paper, oil, petrochemicals and chemicals. The two basic types of transmitters are 4-wire devices with separate cables for power supply and output and 2-wire devices that use the same cable for power supply and output, and Yokogawa supplies both. Yokogawa’s 4-wire transmitters are typically used for specific applications such as pH measurement, and its FLXA21 and FLXA202 2-wire transmitters can flexibly accommodate multiple sensors of the four basic types: pH/ORP, conductivity, inductive conductivity and dissolved oxygen. Although the FLXA402 is a 4-wire system, it can connect to multiple sensors, perform diagnostics, and communicate digitally with host systems.

In liquid analyser applications, there is a need for data monitoring systems consisting of integrated sensors and transmitters that are capable of transmitting data directly to a control system, recorder, indicator, or a handheld device such as a tablet. Although such integrated devices are able to store data that is needed for calibration and other maintenance tasks, the entire unit needs to be replaced when sensor damage or fouling occurs due to exposure to liquids. To reduce maintenance costs, Yokogawa has developed the SA11 smart adaptor, which also functions as a transmitter. As only the sensor needs to be replaced, this significantly reduces maintenance costs and eliminates waste.

Product features

The new products are the FLXA402 4-wire liquid analyser, SA11 SENCOM smart adaptor, and pH and ORP sensors that are dedicated for use with the SA11. There is also a new peripheral device: the BA11 junction box.

FLXA402 4-wire liquid analyser

Reduced cost and footprint: the instrument can work with existing analog sensors (pH/ORP, conductivity, inductive conductivity, and dissolved oxygen), optical dissolved oxygen sensors, and the SA11 Sencom smart adaptor and its dedicated sensors. By using it in combination with the adaptor and the BA11 junction box, it is possible to connect up to five sensors, reducing both system cost and footprint. For the transfer of diagnostic data and other device information to a host system, the device supports the HART and Modbus protocols. This solution also facilitates connection to the cloud and an IIoT environment for improved field maintenance.

SA11 SENCOM smart adaptor

Simple but flexible system configuration: the adaptor has functions for data conversion, transmission, calibration, and diagnosis, and is intended for use with dedicated sensors. It supports the Modbus communications protocol. Using the adaptor, it is easy to set up a system that can perform data monitoring, calibration, setting, and adjustment.

Improved maintenance efficiency

As the SA11 is able to store sensor calibration data and other types of digital information, it can be transferred to a laboratory or some other location that is safer and has better working conditions. This reduces the amount of maintenance work that needs to be performed in the field and helps to ensure that the device stays properly calibrated, thus reducing downtime.

For more information contact Eugene Podde, Yokogawa South Africa, +27 11 831 6300, [email protected], www.yokogawa.com/za



Credit(s)



Share this article:
Share via emailShare via LinkedInPrint this page

Further reading:

Elevating mining separation processes through precision instrumentation
Endress+Hauser South Africa Analytical Instrumentation & Environmental Monitoring
In mining operations, the quest for efficiency and productivity is key. There is an urgent need for innovative solutions to enhance the performance of extraction processes while balancing operational costs and environmental impact.

Read more...
Alfa Laval launches next generation
Analytical Instrumentation & Environmental Monitoring
Alfa Laval has launched Clariot, a next generation, AI-based condition monitoring solution, precision-built for hygienic process equipment to deliver more accurate analysis and support.

Read more...
The next generation in metal sorting
Mecosa Analytical Instrumentation & Environmental Monitoring
In the metal recycling industry, companies are increasingly challenged to not only improve the efficiency of their processes but also to raise the quality and purity of the sorted materials to new levels. By integrating proven spectral analysis technology into its market-leading REDWAVE XRF sorting system, REDWAVE is unlocking new opportunities for metal recycling, particularly in aluminium recovery.

Read more...
Ensuring clean and safe water
Endress+Hauser South Africa Analytical Instrumentation & Environmental Monitoring
Endress+Hauser’s comprehensive range of disinfection sensors are designed to monitor and control disinfectant levels in water treatment processes.

Read more...
Inline OCR measurement systems for real-time oil monitoring in refrigerants
Analytical Instrumentation & Environmental Monitoring
[Sponsored] Anton Paar’s L-Sonic 6100 offers a reliable, real-time inline measurement solution for monitoring the oil circulation ratio in cooling and refrigeration systems.

Read more...
Anton Paar launches inline refractometers for precision Brix monitoring
Anton Paar Analytical Instrumentation & Environmental Monitoring
[Sponsored] Anton Paar has introduced innovative inline refractometers that are designed for continuous Brix concentration monitoring in metalworking machines, fruit and vegetable processing and other industrial processes.

Read more...
Supporting fast, safe helicopter service across Sweden
ATEQ South Africa Analytical Instrumentation & Environmental Monitoring
In an environment with high risks and fierce competition, Storm Heliworks’ fleet of eight helicopters operates on assignments throughout Scandinavia. Maintenance is critical, and the company recently invested in a battery charger analyser from ATEQ Aviation.

Read more...
WearCheck introduces advanced Legionella testing to safeguard water quality
Wearcheck Analytical Instrumentation & Environmental Monitoring
WearCheck Water has expanded its expertise in water analysis with the introduction of Legionella pneumophila detection and enumeration. This positions the company at the forefront of water and surface safety monitoring, ensuring businesses, industries, and public institutions can proactively manage legionella contamination risks.

Read more...
Silo weighing made easy - new mounting kit for load cells
Analytical Instrumentation & Environmental Monitoring
The PR 6003 mounting kit features fast commissioning in demanding applications in industrial silo weighing. It combines maximum accuracy with maximum safety in a compact system.

Read more...
Inline beverage analyser leverages advanced multi-parameter technology
Analytical Instrumentation & Environmental Monitoring
[Sponsored] The Cobrix 7501/7601 inline beverage analyser leverages advanced multi-parameter technology to enhance quality control in carbonated soft drink production.

Read more...









While every effort has been made to ensure the accuracy of the information contained herein, the publisher and its agents cannot be held responsible for any errors contained, or any loss incurred as a result. Articles published do not necessarily reflect the views of the publishers. The editor reserves the right to alter or cut copy. Articles submitted are deemed to have been cleared for publication. Advertisements and company contact details are published as provided by the advertiser. Technews Publishing (Pty) Ltd cannot be held responsible for the accuracy or veracity of supplied material.




© Technews Publishing (Pty) Ltd | All Rights Reserved