Analytical Instrumentation & Environmental Monitoring


Pump station gas detection system

September 2000 Analytical Instrumentation & Environmental Monitoring

Scott/Bacharach, represented locally by Measuretech, a Tyco International company, is offering what it believes is a unique pump station gas detection system within their range of products.

In sewage pumping/lift stations, build-up of methane, hydrogen sulphide and other gasses which displace oxygen can pose severe risk to both personnel and property. The Scott/Bacharach system comprises a four-channel receiver and three to four individual gas transmitters. The receiver provides a common three-digit display of gas concentration, which can scan through all measured channels or be locked onto an individual channel. Individual channel LED indications of Low, High & Fail alarms are simply programmed and common relays enable remote annunciation of alarm, power loss and the unlikely event of transmitter failure.

The explosion-proof transmitters display the gas concentration and provide a 4 to 20 mA signal back to the receiver. All transmitter parameter adjustments are done nonintrusively and the system is equipped with local inhibit, ensuring true single-operator calibration.

There are pinless 'pop-in' sensor connections on the oxygen and hydrogen sulphide transmitters and a self-diagnostics feature to detect loop failure and indicate sensor life expenditure. These are standard features on this UL approved monitoring system.

The truly versatile pump station gas detection system from Scott/Bacharach forms part of an extensive range of fixed toxic and combustible gas detection systems as well as flame detection, paper tape detectors and a full range of portable products for measurement of almost every source of gas leakage.

The recent merger of three of the world's major gas detection companies, Scott, Bacharach & EIT place Measuretech in a good position to be able to provide modern products to suit each industry's applications.

Measuretech

(011) 455 5710

adeans@tyco-valves.com

www.scottbacharach.com





Share this article:
Share via emailShare via LinkedInPrint this page

Further reading:

Why measurement matters in smelting
Endress+Hauser South Africa Analytical Instrumentation & Environmental Monitoring
South African smelters returning to operation after energy constraints face new demands for tighter control, better visibility and environmental compliance. Endress+Hauser explains how modern measurement technology supports safer, more efficient furnace operation and local beneficiation.

Read more...
Sun tracking with pinpoint precision
Senseca Analytical Instrumentation & Environmental Monitoring
Senseca has introduced the SEMS-2000 solar energy measurement system, a 2-axis solar tracker with pinpoint sun-pointing accuracy that automatically monitors direct, global and diffuse irradiance for unattended outdoor solar installations.

Read more...
AMETEK expands 993X gas analyser series with explosion-proof enclosures
Analytical Instrumentation & Environmental Monitoring
AMETEK Process Instruments has added ATEX and IECEx Zone 1-certified explosion-proof enclosures to its 993X series of gas analysers, enabling reliable installation in Zone 1 hazardous locations where purge gas is unavailable.

Read more...
Why medical device leak testing matters for South Africa's MedTech future
ATEQ South Africa Analytical Instrumentation & Environmental Monitoring
As South Africa works to grow local medical technology manufacturing, non-destructive leak and flow testing is becoming a strategic quality assurance tool, helping manufacturers verify device integrity, meet regulatory requirements and improve production efficiency.

Read more...
Moving forward with reverse osmosis
Analytical Instrumentation & Environmental Monitoring
Rising water costs and pressure on infrastructure are changing the way industries view reverse osmosis. G-Chem Aquacare is developing tailored, containerised solutions that make the technology more accessible for South African industry.

Read more...
Meteorological data logger with up to 32 analogue sensors
Senseca Analytical Instrumentation & Environmental Monitoring
Senseca has introduced its advanced data acquisition system for environmental monitoring, which has a universal data logger for up to 32 analogue, pulse and smart digital sensors.

Read more...
Importance of gas analysis in the petrochemical industry
Elemental Analytics Analytical Instrumentation & Environmental Monitoring
Gas analysis plays a critical role in petrochemical operations, supporting process optimisation, product quality and plant safety. As an experienced and expert gas analysis supplier, Elemental Analytics can provide the correct analyser and sample system package to meet individual plant requirements.

Read more...
Fully integrated standalone thunderstorm warning system
Senseca Sensors & Transducers Analytical Instrumentation & Environmental Monitoring
Senseca South Africa has introduced its BTD-1 fully integrated, standalone thunderstorm warning system, which detects lightning by monitoring the background quasi-electrostatic field. The system can generate alerts before the first lightning strike, with a detection raterange of up to 83 km.

Read more...
Environmental monitoring with testo Saveris 1
Analytical Instrumentation & Environmental Monitoring
The testo Saveris 1 environmental monitoring system has been in continuous use since 2010 at Jungbunzlauer, a biotechnology company in Germany, providing seamless temperature and humidity data for audit-ready, GxP-compliant processes across laboratories, warehouses and production areas.

Read more...
Reliability restored through systemic vibration analysis
Wearcheck Analytical Instrumentation & Environmental Monitoring
Condition monitoring specialist, WearCheck uses a variety of testing techniques to enhance reliability in machinery components and prevent failures.

Read more...









While every effort has been made to ensure the accuracy of the information contained herein, the publisher and its agents cannot be held responsible for any errors contained, or any loss incurred as a result. Articles published do not necessarily reflect the views of the publishers. The editor reserves the right to alter or cut copy. Articles submitted are deemed to have been cleared for publication. Advertisements and company contact details are published as provided by the advertiser. Technews Publishing (Pty) Ltd cannot be held responsible for the accuracy or veracity of supplied material.




© Technews Publishing (Pty) Ltd | All Rights Reserved