Fieldbus & Industrial Networking


Smart Wireless vibrating fork liquid level switch

October 2012 Fieldbus & Industrial Networking

Emerson Process Management has enhanced its Rosemount 2160 IEC 62591 (WirelessHART) vibrating fork liquid level switch with faster update rates and advanced broadcasting functions to improve its suitability for critical level control applications. The 2160 also features improved diagnostic capabilities that help to reduce plant maintenance costs. Typical applications for the level device include overfill protection, high and low level alarms, pump control (limit detection), pump protection and empty pipe detection.

The Rosemount 2160 level switch now provides one second update rates, extending the range of suitable level control applications to include fast moving applications such as those found in batch filling. Wireless network redundancy and robustness enable customers to extend their use to critical monitoring and control applications.

For monitoring applications, a unique trending capability enables the collection of data samples for a specified device variable. This reduces the number of transmissions over the wireless network, optimising power module life. A new advanced broadcasting function ensures that changes in process value, frequency of the vibrating fork, battery voltage or temperature are transmitted immediately, thereby improving both safety and diagnostic capability.

The 2160 has no moving parts and requires minimal maintenance. The condition of the forks is continuously monitored to help identify corrosion, build up or damage. Plant-wide alerts can be configured to warn of changes in an instrument’s status, giving operators advanced warning of any potential instrument health problems. Should an operator need to inspect the unit, a new ‘squawk’ feature helps identify a specific device. An integral LCD display showing switch output states and diagnostics provides real time, accurate verification of process conditions.

The 2160 liquid level switch is virtually unaffected by flow, bubbles, turbulence, foam, vibration, solids content, coating, liquid properties and product variations. It is designed for use in extreme temperatures and performs in harsh process conditions that are unsuitable for other switches. Two models are available, covering the temperature range -68 to 260°C.

For more information contact Mark Tapson, Emerson Process Management, +27 (0)11 451 3700, [email protected], www.emersonprocess.com



Credit(s)



Share this article:
Share via emailShare via LinkedInPrint this page

Further reading:

A one-stop-shop for industrial
Fieldbus & Industrial Networking
HMS Networks has announced that Red Lion and N-Tron are officially product brands. For thousands of automation engineers and system integrators worldwide, this means that scalable industrial solutions for cloud connectivity, edge intelligence, asset management, industrial Ethernet switches, panel meters and operator panels are now available from one trusted source.

Read more...
Power over Ethernet (PoE) injector for seamless deployment
Vepac Electronics Fieldbus & Industrial Networking
The Edimax GP-203IT from Vepac Electronics is a Power over Ethernet injector that not only delivers a cost-effective solution for power distribution, but also enables seamless deployment on the existing LAN infrastructure.

Read more...
A one-stop-shop for industrial communication
Fieldbus & Industrial Networking
HMS Networks has announced that Red Lion and N-Tron are officially product brands. For thousands of automation engineers and system integrators worldwide, this means that scalable industrial solutions for cloud connectivity, edge intelligence, asset management, industrial Ethernet switches, panel meters and operator panels are now available from one trusted source.

Read more...
Cost-effective industrial PoE injector
Vepac Electronics Fieldbus & Industrial Networking
The Edimax IGP-203IT from Vepac Electronics is an industrial PoE injector that not only delivers a cost-effective solution for power distribution, but also allows seamless deployment on an existing LAN infrastructure.

Read more...
Harnessing the power of OT networking
RJ Connect Fieldbus & Industrial Networking
Businesses are increasingly embracing IT/OT convergence to stay ahead and capitalise on advantages such as smarter factories and higher efficiency. This article provides practical insights and guidance to help you navigate these challenges effectively.

Read more...
PC-based control for advanced hydrogen storage technology
Beckhoff Automation Fieldbus & Industrial Networking
Sufficient storage options for renewable energies are essential to use them as efficiently as possible. GKN Hydrogen offers a particularly compact and safe option, low-pressure metal hydride hydrogen storage systems with PC-based control from Beckhoff.

Read more...
Power over Ethernet splitter without electric cabling
Vepac Electronics Fieldbus & Industrial Networking
The GP-101ST Gigabit PoE (Power over Ethernet) Splitter from Vepac Electronics delivers both data and electrical power to non-PoE Fast Ethernet or Gigabit Ethernet-enabled products such as network cameras and wireless access points, using an Ethernet cable, without the need for power outlets and electrical cabling.

Read more...
Beckhoff’s XPlanar boosts productivity in medical device assembly
Beckhoff Automation Fieldbus & Industrial Networking
The intelligent transport system, XPlanar from Beckhoff provided the basis for an innovative system concept allowing the specialists at Automation NTH to reduce the space requirement of an assembly machine for medical diagnostic devices by a factor of 10.

Read more...
Comprehensive solutions for the food and beverage sector
RS South Africa Fieldbus & Industrial Networking
RS South Africa is reinforcing its commitment to the country’s dynamic food and beverage sector, backed by a comprehensive portfolio of over 800 000 products, extensive technical expertise and end-to-end service capabilities.

Read more...
Case History 198: Cascade control overcomes valve problems
Michael Brown Control Engineering Fieldbus & Industrial Networking
A large petrochemical refinery asked me to perform an audit on several critical base layer control loops. This article deals with a problem found on a valve controlling the flow of fuel to a heat exchanger.

Read more...









While every effort has been made to ensure the accuracy of the information contained herein, the publisher and its agents cannot be held responsible for any errors contained, or any loss incurred as a result. Articles published do not necessarily reflect the views of the publishers. The editor reserves the right to alter or cut copy. Articles submitted are deemed to have been cleared for publication. Advertisements and company contact details are published as provided by the advertiser. Technews Publishing (Pty) Ltd cannot be held responsible for the accuracy or veracity of supplied material.




© Technews Publishing (Pty) Ltd | All Rights Reserved