Fieldbus & Industrial Networking


Integrating fire alarm systems into building management systems

October 2025 Fieldbus & Industrial Networking


Fire alarm systems work independently of the building automation system. Having detailed information about the state of the fire protection technology would make the work of many facility managers easier. Schrack Seconet has developed a flexible gateway using ultra-compact industrial PCs and TwinCAT from Beckhoff, which can be used to flexibly convert a customer-specific communication protocol to a wide range of transmission standards such as BACnet or OPC UA. “Customers told us that they needed further interfaces in addition to the protocols supported by our fire alarm systems,” says Paul Panzitt, product manager for fire alarm systems at Schrack Seconet in Vienna.

Schrack Seconet offers the gateway as a supplement to the fire alarm systems, allowing operators to integrate the status and alarm messages of the systems into their building management technology. Due to the variety of building management systems that are available, it must be possible to implement a wide range of different transmission protocols. “TwinCAT 3 connectivity provides a wide variety of protocols for this purpose. They range from classic TCP/IP-based protocols to SMS/SMTP servers, JSON, MQTT or HTTPS/REST and WebSockets. These direct integration with databases and cloud storage such as Amazon AWS and Microsoft Azure,” says Balazs Bezeczky, head of the Beckhoff sales office in Vienna.

ISP-IP protocol recoded

The fire alarm systems send the status and alarm messages via ISP-IP to a C6015 or C6030 ultra-compact Industrial PC. “The conversion of the specific protocol to BACnet and OPC UA was realised as a C# program and implemented in TwinCAT,” says Georg Schemmann, head of industry management building automation at Beckhoff. Due to the openness of PC-based control and TwinCAT as an engineering platform, the program can be combined with any other TwinCAT function in order to allow the fire alarm systems to communicate with the respective management technology.

The gateway primarily provides the building management system with alarms or status messages, which can then be integrated into the building visualisation. As communication via the gateways is bidirectional, the building technician can shut down individual detector groups or adjust the operating mode during maintenance. “All of this can be operated centrally via the visualisation of the building management system using the gateway implemented with Beckhoff technology,” says Schemmann. Panzitt adds: “Schrack Seconet already supports such use cases via its own service platform, to which our fire alarm systems send all relevant information. In principle, TwinCAT could be used to extract further information from the transmitted data, such as the degree of contamination of a smoke detector, and make it available to different end devices via TwinCAT HMI Server, for example.”

Simple scaling and retrofitting

Depending on the size of the fire alarm systems, Schrack Seconet uses a C6015 or C6030 ultra-compact Industrial PC. “The easy scalability of the computing power is important as we have fire alarm systems ranging from 200 to over 50 000 data points,” says Panzitt. “A C6015 is used up to around 10 000 data points. Above that, the even more powerful C6030 comes into play. In addition to flexibility and scalability, simple implementation without the need for in-depth training was another criterion when choosing the system.”

The clear separation between the gateway and the fire alarm system also enables easy implementation in existing buildings without the fire alarm system having to be approved again. “We can use the converter solution to integrate with any control system. We only get positive feedback from our customers because it is easy to implement and it works,” says Panzitt. Even systems that are several decades old can be retrofitted with advanced communication protocols, without having to replace the entire fire alarm system. “With TwinCAT, we support a wide variety of communication protocols used in industry, building automation and IT, and are constantly implementing new standards as required,” says Bezeczky.

Using fire protection technology for room automation

Schrack Seconet’s converter solution currently focuses on exchanging fire protection data with the building management system, i.e., alarms and status messages. However, the fire detectors also register additional information, such as the temperature or CO concentration in the air. It would be conceivable to evaluate these measured values in the next generation of fire alarm systems and to use them in the building management system to monitor air quality and for room air conditioning. “Looking to the future, this is an exciting idea that would save a lot of additional sensors and therefore costs,” concludes Panzitt.


Credit(s)



Share this article:
Share via emailShare via LinkedInPrint this page

Further reading:

Why secure industrial communication depends on deployment as well
Fieldbus & Industrial Networking
The Industrial Security Harmonisation Group has released a joint industry perspective highlighting a critical truth in industrial cybersecurity: secure communication is not determined by protocols alone, but by how they are deployed and managed in real-world environments.

Read more...
A single platform for all automation functions
Beckhoff Automation Fieldbus & Industrial Networking
The introduction of TwinCAT in 1996 marked a decisive evolutionary step for PC-based control. Today, the TwinCAT platform combines all automation functions in a strictly deterministic real-time environment, from PLC and motion control through CNC and measurement technology and beyond, to vision, robotics and pioneering AI tools.

Read more...
Dynamic control of industrial solar plants and energy storage systems
Beckhoff Automation Editor's Choice Electrical Power & Protection
Spanish Group, Power Electronics has demonstrated its comprehensive expertise in sustainable energy supply in over 3000 solar and energy storage projects with a total installed capacity of 120 GW. To control its modular systems, the company relies on open, high-performance Beckhoff control technology.

Read more...
Loop signature Part 2-4: Feedforward Control: Part 3
Michael Brown Control Engineering Editor's Choice Fieldbus & Industrial Networking
In the previous articles in this series, the basic theory behind feedforward control was discussed, and it was also shown how to apply feedforward in practice. In this article, it will be shown how well feedforward can work in practice by giving a couple of examples.

Read more...
Control Station and Dimension Software partner to connect control performance monitoring with enterprise operations intelligence
Fieldbus & Industrial Networking
Control Station has entered into a strategic technology partnership with Dimension Software, a leading provider of industrial operations management platforms. The collaboration connects Control Station’s PlantESP control loop performance monitoring platform with Dimension Software’s Asset Intellect operations intelligence environment, enabling manufacturers to operationalise control performance insights across their organisations.

Read more...
PCIe digitiser cards for optimal GHz signal acquisition and analysis
Vepac Electronics Fieldbus & Industrial Networking
The addition of two new PCIe Digitiser cards from Spectrum Instrumentation extends the company’s flagship M5i series to deliver optimal GHz signal acquisition and analysis capabilities.

Read more...
Precise, synchronised control for automated steel mesh handling system
Fieldbus & Industrial Networking
Automation specialist Hambi Maschinenbau has developed a world-first system that automates the cutting, handling and stacking of heavy reinforcing steel mesh – a task that previously required up to six human operators.

Read more...
Modular control platform for the hydrogen industry
Beckhoff Automation Editor's Choice Electrical Power & Protection
With a seamless modular control solution from Beckhoff featuring over 500 data points and numerous ELX series terminals with intrinsically safe interfaces, Greenlight Innovation is breaking new ground in hydrogen testing.

Read more...
Loop signature Part 2-3: Feedforward Control: Part 2
Michael Brown Control Engineering Editor's Choice Fieldbus & Industrial Networking
Feedforward control tuning is not nearly as critical as feedback tuning, and fairly simple models are usually fine for the purpose in hand.

Read more...
Upgrading radiological surveillance systems in nuclear facilities
Omniflex Remote Monitoring Specialists Fieldbus & Industrial Networking
Nuclear plant operators face an uncomfortable reality. Many of the control and monitoring systems still in use today were never designed to support the full operational lifespan of the facilities they serve.

Read more...









While every effort has been made to ensure the accuracy of the information contained herein, the publisher and its agents cannot be held responsible for any errors contained, or any loss incurred as a result. Articles published do not necessarily reflect the views of the publishers. The editor reserves the right to alter or cut copy. Articles submitted are deemed to have been cleared for publication. Advertisements and company contact details are published as provided by the advertiser. Technews Publishing (Pty) Ltd cannot be held responsible for the accuracy or veracity of supplied material.




© Technews Publishing (Pty) Ltd | All Rights Reserved