October 2012Analytical Instrumentation & Environmental Monitoring
Monitoring pH and ORP in the bleaching tower exposes pH electrodes to high temperatures and harsh conditions, shortening electrode life and leading to higher maintenance. Mettler Toledo offers its Ingold InPro 4801 SG flat glass pH electrode in a titanium hot-tap housing, along with the M800 transmitter, as a high-performance measuring point for use in the pulp and paper industry.
The InPro 4801 solution ground (SG) flat glass pH electrode is a low maintenance, dual-purpose electrode that is ideal for high temperature and high pressure environments. It is specially designed for operation in oxidant media and, due to its flat membrane glass, is much less susceptible to fouling. Moreover, it allows the measurement of both pH and redox simultaneously off the same electrode.
The M800 multi-parameter transmitter provides simultaneous monitoring of up to four in-line sensors with intelligent sensor management (ISM) technology for measurement of pH/ORP, optical DO, amperometric oxygen, conductivity, resistivity, dissolved ozone and flow.
The InPro 4801 SG electrode offers reliable measurements in oxidising media, strong acid or alkali solutions and sulphide-bearing media. The hot-tap style housing allows for continuous and safe access to the electrode, meaning that maintenance can be done without interrupting the process, despite the high operational pressure. In addition, the electrode performs for a long period of time before cleaning or calibration is required, thus reducing maintenance and replacement costs.
The InPro 4801 SG with a flat glass membrane and solution ground feature is the optimal choice for media with particles and fibres. Ground loops can be avoided with the solution ground, which can also be used as a diagnostic tool. The SG feature as an entire electrode body coating or as a measuring point on a pH-electrode, will improve grounding and effectively eliminate the risk of electrostatic interference. SG also improves advanced diagnostic functions, and makes parallel pH/redox measurement possible.
Matching HVAC to the real demands of buildings and processes
Analytical Instrumentation & Environmental Monitoring
Industrial Climate Engineering director, Alin Gomes explains why effective HVAC goes beyond specifying equipment on capacity, covering load profiling, ventilation requirements, heat recovery and turnkey delivery for specialised manufacturing and processing environments.
Read more...How SCE approaches sensor selection for critical environments Specialised Climate Engineering
Analytical Instrumentation & Environmental Monitoring
Specifying the right sensor for a critical climate involves far more than matching a datasheet accuracy figure. As an authorised Vaisala HVAC partner, SCE explains how understanding the environment, the measurement purpose and sensor placement determines effective climate control.
Read more...Changing gas quality calls for smarter combustion control
Analytical Instrumentation & Environmental Monitoring
As South Africa prepares for a transition from declining Mozambican natural gas to a proposed methane-rich bridge, LNG, industrial users can no longer assume a constant Wobbe Index and calorific value. The compact RMG RGQ 5 provides fast, plant-level gas-quality data to support approved burner and engine settings.
Read more...Getting the chemistry right
Analytical Instrumentation & Environmental Monitoring
Grace’s European production site has relied on analogue compression load cells from Minebea Intec for decades, with the long-proven measurement concept now serving as the reference for new silo projects as the company expands its capacity.
Read more...Why measurement matters in smelting Endress+Hauser South Africa
Analytical Instrumentation & Environmental Monitoring
South African smelters returning to operation after energy constraints face new demands for tighter control, better visibility and environmental compliance. Endress+Hauser explains how modern measurement technology supports safer, more efficient furnace operation and local beneficiation.
Read more...Sun tracking with pinpoint precision Senseca
Analytical Instrumentation & Environmental Monitoring
Senseca has introduced the SEMS-2000 solar energy measurement system, a 2-axis solar tracker with pinpoint sun-pointing accuracy that automatically monitors direct, global and diffuse irradiance for unattended outdoor solar installations.
Read more...AMETEK expands 993X gas analyser series with explosion-proof enclosures
Analytical Instrumentation & Environmental Monitoring
AMETEK Process Instruments has added ATEX and IECEx Zone 1-certified explosion-proof enclosures to its 993X series of gas analysers, enabling reliable installation in Zone 1 hazardous locations where purge gas is unavailable.
Read more...Why medical device leak testing matters for South Africa's MedTech future ATEQ South Africa
Analytical Instrumentation & Environmental Monitoring
As South Africa works to grow local medical technology manufacturing, non-destructive leak and flow testing is becoming a strategic quality assurance tool, helping manufacturers verify device integrity, meet regulatory requirements and improve production efficiency.
Read more...Moving forward with reverse osmosis
Analytical Instrumentation & Environmental Monitoring
Rising water costs and pressure on infrastructure are changing the way industries view reverse osmosis. G-Chem Aquacare is developing tailored, containerised solutions that make the technology more accessible for South African industry.
Read more...Meteorological data logger with up to 32 analogue sensors Senseca
Analytical Instrumentation & Environmental Monitoring
Senseca has introduced its advanced data acquisition system for environmental monitoring, which has a universal data logger for up to 32 analogue, pulse and smart digital sensors.
While every effort has been made to ensure the accuracy of the information contained herein, the publisher and its agents cannot be held responsible for any errors contained, or any loss incurred as a result. Articles published do not necessarily reflect the views of the publishers. The editor reserves the right to alter or cut copy. Articles submitted are deemed to have been cleared for publication. Advertisements and company contact details are published as provided by the advertiser. Technews Publishing (Pty) Ltd cannot be held responsible for the accuracy or veracity of supplied material.