In hazardous locations, local panels must perform vital safety functions without compromising the integrity of the hazardous area. Annunciators have a primary safety role in local panel design to provide immediate alert and response to danger.

Based on the field proven Omni16 alarm annunciator range, the Omni16 C1480B-EXN is a non-sparking backlit unit developed for use in these hazardous environments. The device accepts 16 potential free inputs and displays a visual warning when a critical alarm is triggered. Since it is non-sparking there is no danger of igniting any combustible gas or dust that may be present in the air.

The alarm sequences for the 16 inputs are configured by software or DIP switch, with a choice of 27 standard sequences available. Four output relays can be configured as group alarm, horn output and watchdog with a change over contact at the terminals. The group alarm can be set to one of four functions, follows input, follows alarm, multiple re-flash, and ring back horn.

Omni C1480B-EXN has been certified by SABS as equipment category Ex nL in accordance with international standards IEC60079-0 and IEC60079-15. C1480B-EXN is suitable for use in hazardous areas classified as Zone 2, gas and dust, propane to hydrogen.

For more information contact Ian Loudon, Omniflex, +27 (0)31 207 7466, [email protected], www.omniflex.com



Credit(s)



Share this article:
Share via emailShare via LinkedInPrint this page

Further reading:

Omniflex through the decades
Omniflex Remote Monitoring Specialists News
As Omniflex celebrates 60 years of engineering excellence, we take a look back at the decade that saw us really kick in and deliver major engineering projects – the 1970s.

Read more...
Remote monitoring in remote and harsh environments
Omniflex Remote Monitoring Specialists Industrial Wireless
For power grids, water supply networks and many industrial facilities, managing infrastructure in remote locations is a significant challenge. Omniflex discusses the requirements for remote monitoring equipment deployed in remote and harsh environments, and shares an example from the company’s work with a South African electricity supply company.

Read more...
Plant to control room visibility
Omniflex Remote Monitoring Specialists Industrial Wireless
When Sasol’s Secunda power plant in South Africa was looking for ways to improve productivity and maintenance responsiveness, it approached remote monitoring experts, Omniflex for real-time monitoring of its electrostatic precipitators across 17 substations.

Read more...
Certified safe power for hazardous industrial environments
Conical Technologies IS & Ex
When working in high-risk environments like oil and gas, petrochemical plants or other hazardous industrial zones, safety isn’t just important, it’s essential. That’s why Traco Power developed the TIB-EX series of DIN rail power supplies, purpose-built to deliver reliable power even in the toughest conditions.

Read more...
Parker strengthens explosion safety
IS & Ex
Parker Hannifin has announced that its 37 mm Ex d m coils have attained new ATEX and IECEx Type Examination Certificates according to the latest explosion protection standards.

Read more...
Upgrading Australia’s first switch-mode CP installation
Omniflex Remote Monitoring Specialists Industrial Wireless
Omniflex has completed a system upgrade for the switch-mode cathodic protection system installation protecting a premium residential precinct in Melbourne, upgrading its remote monitoring with 4G connectivity

Read more...
New modules for distributed integration of intrinsically safe signals
Beckhoff Automation IS & Ex
Beckhoff provides a compact acquisition solution for intrinsically safe signals up to zone 0/20 with the IP67-protected EtherCAT Box modules of the EPX series.

Read more...
Novel closed-loop CP technology wins innovation award
Omniflex Remote Monitoring Specialists Industrial Wireless
Researchers at Deakin University have won the Corrosion Innovation of the Year Award at this year’s AMPP Annual Conference and Expo in Nashville, USA. The award recognised the development of a novel closed-loop cathodic protection system for localised corrosion control in challenging industrial environments, which Omniflex helped with as a technology partner.

Read more...
Stopping the sparks from flying
IS & Ex
Whenever electrical equipment is required for use in hazardous environments they must be designed with intrinsic safety in mind. Darren Barratt, product sales manager at alarm and event management specialist, Omniflex outlines the importance and key aspects of intrinsic safety design.

Read more...
Improved networking technology for fire and gas detection
Omniflex Remote Monitoring Specialists Fieldbus & Industrial Networking
Critical alarm and event management technology supplier, Omniflex has worked with the South African Nuclear Energy Corporation to upgrade equipment providing digital and analogue signals for its safety critical fire and gas alarm systems.

Read more...









While every effort has been made to ensure the accuracy of the information contained herein, the publisher and its agents cannot be held responsible for any errors contained, or any loss incurred as a result. Articles published do not necessarily reflect the views of the publishers. The editor reserves the right to alter or cut copy. Articles submitted are deemed to have been cleared for publication. Advertisements and company contact details are published as provided by the advertiser. Technews Publishing (Pty) Ltd cannot be held responsible for the accuracy or veracity of supplied material.




© Technews Publishing (Pty) Ltd | All Rights Reserved