Analytical Instrumentation & Environmental Monitoring


Analyser measures five gases simultaneously

July 2007 Analytical Instrumentation & Environmental Monitoring

The ENDA-600 series from Horiba includes a single analyser unit that measures NOX, SOx, CO, CO2 and O2. Using cross-flow modulated NDIR (non-dispersive infrared absorbance) detection - a method that is inherently drift-free - and a magneto-pneumatic bench for oxygen measurement (based on the principle that oxygen can be attracted into a magnetic field), this analyser provides long time stability, reducing the required frequency of calibrations.

A pyro-sensor monitors CO2 concentration in the sample gas. Since the analyser inherently has no zero drift, measurements are more stable over time. Because of this stability, the auto-calibration function is factory set to calibrate once in a seven-day period, and may be configured to calibrate from one to nine days.

For applications with high-dust samples, such as coal-fired boiler exhaust, a primary filter in the probe prevents dust from entering the sample system.

The analyser can be set to output instantaneous values on all five measured components, oxygen conversion values for three components, and the moving average for any two of the five measured components for a period anywhere from one to four hours.

An output port option is available to connect the system to an external device for remote confirmation of the system status. Since ambient air is used as the carrier gas for the oxygen bench, there is no need for cylinders of nitrogen carrier gas, saving valuable space and reducing operating costs.

A stainless steel sample gas probe is connected directly to the primary filter, while the dehumidifying system minimises loss of SO2 and NO2 from the sample gas.

For samples containing flammable or poisonous gases, a sample return line and a sample purge line can be provided. A purged enclosure is available for environments where flammable or poisonous gases may be present.

For more information contact Noel Bauchop, OEN Enterprises, +27 (0)11 675 4447, [email protected], www.oenenterprises.co.za





Share this article:
Share via emailShare via LinkedInPrint this page

Further reading:

Importance of gas analysis in the petrochemical industry
Elemental Analytics Analytical Instrumentation & Environmental Monitoring
Gas analysis plays a critical role in petrochemical operations, supporting process optimisation, product quality and plant safety. As an experienced and expert gas analysis supplier, Elemental Analytics can provide the correct analyser and sample system package to meet individual plant requirements.

Read more...
Fully integrated standalone thunderstorm warning system
Senseca Sensors & Transducers Analytical Instrumentation & Environmental Monitoring
Senseca South Africa has introduced its BTD-1 fully integrated, standalone thunderstorm warning system, which detects lightning by monitoring the background quasi-electrostatic field. The system can generate alerts before the first lightning strike, with a detection raterange of up to 83 km.

Read more...
Environmental monitoring with testo Saveris 1
Analytical Instrumentation & Environmental Monitoring
The testo Saveris 1 environmental monitoring system has been in continuous use since 2010 at Jungbunzlauer, a biotechnology company in Germany, providing seamless temperature and humidity data for audit-ready, GxP-compliant processes across laboratories, warehouses and production areas.

Read more...
Reliability restored through systemic vibration analysis
Wearcheck Analytical Instrumentation & Environmental Monitoring
Condition monitoring specialist, WearCheck uses a variety of testing techniques to enhance reliability in machinery components and prevent failures.

Read more...
Meteorological data logger with up to 32 analogue sensors
Senseca Analytical Instrumentation & Environmental Monitoring
Senseca has introduced its advanced data acquisition system for environmental monitoring, which has a universal data logger for up to 32 analogue, pulse and smart digital sensors.

Read more...
Yokogawa’s free chlorine analyser is gold standard for water treatment utilities
Yokogawa South Africa Analytical Instrumentation & Environmental Monitoring
One of the key factors in ensuring safe drinking water is the accurate monitoring of free chlorine residuals. This is where advanced online analysers, such as Yokogawa’s FC800 free chlorine analyser, are becoming increasingly valuable for water treatment operators and municipal utilities.

Read more...
Cooling tower bleed control
Analytical Instrumentation & Environmental Monitoring
Cooling towers rely on evaporation to remove heat, but this process also concentrates dissolved solids in the system. Left unmanaged, this buildup can lead to scaling, corrosion and fouling, reducing efficiency and increasing maintenance costs.

Read more...
Expanded test laboratory provides polymer users with more information
igus Analytical Instrumentation & Environmental Monitoring
igus has expanded its international testing facilities to accommodate its increasing product portfolio and enable continuous improvement of its product quality.

Read more...
Filters for zero-alcohol wine
Parker Hannifin - Sales Company South Africa Analytical Instrumentation & Environmental Monitoring
The market for zero-alcohol wine is creating fresh opportunities for wine producers, but processing these products creates new contamination challenges. Technical support from an established filtration specialist, such as Parker, can help wineries in overcoming the challenges posed by the increased risk of contamination.

Read more...
Remote monitoring solution for sewage plants
ifm - South Africa Analytical Instrumentation & Environmental Monitoring
With ifm’s remote monitoring solution, you can visualise the condition of the submersible pumps in your sewage plant and diagnose issues before they become serious problems.

Read more...









While every effort has been made to ensure the accuracy of the information contained herein, the publisher and its agents cannot be held responsible for any errors contained, or any loss incurred as a result. Articles published do not necessarily reflect the views of the publishers. The editor reserves the right to alter or cut copy. Articles submitted are deemed to have been cleared for publication. Advertisements and company contact details are published as provided by the advertiser. Technews Publishing (Pty) Ltd cannot be held responsible for the accuracy or veracity of supplied material.




© Technews Publishing (Pty) Ltd | All Rights Reserved