Analytical Instrumentation & Environmental Monitoring


Stack gas analysis system

July 2006 Analytical Instrumentation & Environmental Monitoring

The ENDA-600 Series from Horiba includes a single analyser unit that measures NOX, SO2, CO and CO2 and O2, setting a new standard for continuous emissions monitoring systems. Using cross-flow modulated NDIR detection, a method that is inherently drift-free and a magnetopneumatic bench for oxygen measurement, the ENDA-600 Series provides long time stability, reducing the required frequency of calibrations.

A pyro-sensor acts as a CO2 interference sensor to monitor CO2 concentration in the sample gas. Since the analyser inherently has no zero drift, measurements are more stable over time. Due to this stability, the auto-calibration function is set to calibrate once in a seven-day period, and may be reset to calibrate from one to nine days.

A primary filter in the probe prevents dust from entering the sample system for applications with high-dust samples, such as coal fired boiler exhaust.

The ENDA-600 Series may be set to output instantaneous values on all five measured components, oxygen conversion values for three components, and the moving average for any two of the five measured components for a period anywhere from one to four hours.

An output port is optionally provided to connect the system with an external device for remote confirmation of the system's status. Since ambient air is used as the carrier gas for the oxygen bench, there is no need for cylinders of nitrogen carrier gas, saving valuable space and reducing operating costs.

A stainless steel sample gas probe is connected directly to the primary filter, while the dehumidifying system minimises loss of SO2 and NO2 from the sample gas.

For samples containing flammable or poisonous gases, a sample return line and a sample purge line can be provided as options. An optional purged enclosure is also available for environments where flammable or poisonous gases may be present.

Horiba is represented locally by OEN Enterprises.

For more information contact Noel Bauchop, OEN Enterprises, 011 675 4447, noel@oenenterprises.co.za





Share this article:
Share via emailShare via LinkedInPrint this page

Further reading:

Getting the chemistry right
Analytical Instrumentation & Environmental Monitoring
Grace’s European production site has relied on analogue compression load cells from Minebea Intec for decades, with the long-proven measurement concept now serving as the reference for new silo projects as the company expands its capacity.

Read more...
Why measurement matters in smelting
Endress+Hauser South Africa Analytical Instrumentation & Environmental Monitoring
South African smelters returning to operation after energy constraints face new demands for tighter control, better visibility and environmental compliance. Endress+Hauser explains how modern measurement technology supports safer, more efficient furnace operation and local beneficiation.

Read more...
Sun tracking with pinpoint precision
Senseca Analytical Instrumentation & Environmental Monitoring
Senseca has introduced the SEMS-2000 solar energy measurement system, a 2-axis solar tracker with pinpoint sun-pointing accuracy that automatically monitors direct, global and diffuse irradiance for unattended outdoor solar installations.

Read more...
AMETEK expands 993X gas analyser series with explosion-proof enclosures
Analytical Instrumentation & Environmental Monitoring
AMETEK Process Instruments has added ATEX and IECEx Zone 1-certified explosion-proof enclosures to its 993X series of gas analysers, enabling reliable installation in Zone 1 hazardous locations where purge gas is unavailable.

Read more...
Why medical device leak testing matters for South Africa's MedTech future
ATEQ South Africa Analytical Instrumentation & Environmental Monitoring
As South Africa works to grow local medical technology manufacturing, non-destructive leak and flow testing is becoming a strategic quality assurance tool, helping manufacturers verify device integrity, meet regulatory requirements and improve production efficiency.

Read more...
Moving forward with reverse osmosis
Analytical Instrumentation & Environmental Monitoring
Rising water costs and pressure on infrastructure are changing the way industries view reverse osmosis. G-Chem Aquacare is developing tailored, containerised solutions that make the technology more accessible for South African industry.

Read more...
Meteorological data logger with up to 32 analogue sensors
Senseca Analytical Instrumentation & Environmental Monitoring
Senseca has introduced its advanced data acquisition system for environmental monitoring, which has a universal data logger for up to 32 analogue, pulse and smart digital sensors.

Read more...
Importance of gas analysis in the petrochemical industry
Elemental Analytics Analytical Instrumentation & Environmental Monitoring
Gas analysis plays a critical role in petrochemical operations, supporting process optimisation, product quality and plant safety. As an experienced and expert gas analysis supplier, Elemental Analytics can provide the correct analyser and sample system package to meet individual plant requirements.

Read more...
Fully integrated standalone thunderstorm warning system
Senseca Sensors & Transducers Analytical Instrumentation & Environmental Monitoring
Senseca South Africa has introduced its BTD-1 fully integrated, standalone thunderstorm warning system, which detects lightning by monitoring the background quasi-electrostatic field. The system can generate alerts before the first lightning strike, with a detection raterange of up to 83 km.

Read more...
Environmental monitoring with testo Saveris 1
Analytical Instrumentation & Environmental Monitoring
The testo Saveris 1 environmental monitoring system has been in continuous use since 2010 at Jungbunzlauer, a biotechnology company in Germany, providing seamless temperature and humidity data for audit-ready, GxP-compliant processes across laboratories, warehouses and production areas.

Read more...









While every effort has been made to ensure the accuracy of the information contained herein, the publisher and its agents cannot be held responsible for any errors contained, or any loss incurred as a result. Articles published do not necessarily reflect the views of the publishers. The editor reserves the right to alter or cut copy. Articles submitted are deemed to have been cleared for publication. Advertisements and company contact details are published as provided by the advertiser. Technews Publishing (Pty) Ltd cannot be held responsible for the accuracy or veracity of supplied material.