Analytical Instrumentation & Environmental Monitoring


Portable emission analyser

January 2006 Analytical Instrumentation & Environmental Monitoring

The ECOM-J2K with wireless remote control is a portable emission analyser offering world-class performance in a rugged, user-friendly package. The J2K's handheld remote allows complete wireless operation of the analyser, a large LCD showing all values at a glance, zoom display capability, and plug-in memory up to 128 MB. The remote display feature makes the J2K suitable for where combustion controls are located away from the flue test port on large combustion systems.

The J2K can be fitted with sensors to measure O2, CO, NO, NO2, and SO2 along with gas and ambient temperatures, stack draft and pressure, plus calculations of CO2, efficiency, dew point and excess air. Standard ECOM features include high flow pump with flow meter, integral impact printer, thermoelectric gas cooler with automatic condensate drain, on board data storage, and proven CO over range protection. Sensor life generally averages 2-3 years due to proprietary design of sensor manifold and gas delivery system. Along with superior performance features, the J2K also offers wireless transmission of realtime data via ECOM's Advanced DAS program. Complete emission reports are recorded and stored to the user's laptop while on-site.

Summary of features:

* Complete wireless operation via handheld remote and PC.

* Large graphic display.

* All values at a glance, plus zoom function.

* Plug in memory up to 128 MB.

* High flow pump for quick response time and stable readings.

* On board flowmeter.

* Thermoelectric gas cooler with automatic moisture drain.

* Fuel selection.

* CO overload protection as well as high and low range sensors.

* Sensor temperature compensation for enhanced accuracy.

* Automatic drift correction.

* Integral thermal printer.

* Easy upgrades for custom application.

* Measurements in ppm, mg/m3, mg/kWhr and mg/MJ.

* Long service intervals.

* US EPA reporting structure.

The J2K is delivered to you with a 5 m sample line, 300 mm probe, spare filters, printer paper, and a protective storage case. Custom length heated sample lines are also available for EPA compliance.

For more information contact Stuart Truebody, Environmental Process Analytics, 012 661 6656, [email protected]



Credit(s)



Share this article:
Share via emailShare via LinkedInPrint this page

Further reading:

Elevating mining separation processes through precision instrumentation
Endress+Hauser South Africa Analytical Instrumentation & Environmental Monitoring
In mining operations, the quest for efficiency and productivity is key. There is an urgent need for innovative solutions to enhance the performance of extraction processes while balancing operational costs and environmental impact.

Read more...
Alfa Laval launches next generation
Analytical Instrumentation & Environmental Monitoring
Alfa Laval has launched Clariot, a next generation, AI-based condition monitoring solution, precision-built for hygienic process equipment to deliver more accurate analysis and support.

Read more...
The next generation in metal sorting
Mecosa Analytical Instrumentation & Environmental Monitoring
In the metal recycling industry, companies are increasingly challenged to not only improve the efficiency of their processes but also to raise the quality and purity of the sorted materials to new levels. By integrating proven spectral analysis technology into its market-leading REDWAVE XRF sorting system, REDWAVE is unlocking new opportunities for metal recycling, particularly in aluminium recovery.

Read more...
Ensuring clean and safe water
Endress+Hauser South Africa Analytical Instrumentation & Environmental Monitoring
Endress+Hauser’s comprehensive range of disinfection sensors are designed to monitor and control disinfectant levels in water treatment processes.

Read more...
Inline OCR measurement systems for real-time oil monitoring in refrigerants
Analytical Instrumentation & Environmental Monitoring
[Sponsored] Anton Paar’s L-Sonic 6100 offers a reliable, real-time inline measurement solution for monitoring the oil circulation ratio in cooling and refrigeration systems.

Read more...
Anton Paar launches inline refractometers for precision Brix monitoring
Anton Paar Analytical Instrumentation & Environmental Monitoring
[Sponsored] Anton Paar has introduced innovative inline refractometers that are designed for continuous Brix concentration monitoring in metalworking machines, fruit and vegetable processing and other industrial processes.

Read more...
Supporting fast, safe helicopter service across Sweden
ATEQ South Africa Analytical Instrumentation & Environmental Monitoring
In an environment with high risks and fierce competition, Storm Heliworks’ fleet of eight helicopters operates on assignments throughout Scandinavia. Maintenance is critical, and the company recently invested in a battery charger analyser from ATEQ Aviation.

Read more...
WearCheck introduces advanced Legionella testing to safeguard water quality
Wearcheck Analytical Instrumentation & Environmental Monitoring
WearCheck Water has expanded its expertise in water analysis with the introduction of Legionella pneumophila detection and enumeration. This positions the company at the forefront of water and surface safety monitoring, ensuring businesses, industries, and public institutions can proactively manage legionella contamination risks.

Read more...
Silo weighing made easy - new mounting kit for load cells
Analytical Instrumentation & Environmental Monitoring
The PR 6003 mounting kit features fast commissioning in demanding applications in industrial silo weighing. It combines maximum accuracy with maximum safety in a compact system.

Read more...
Inline beverage analyser leverages advanced multi-parameter technology
Analytical Instrumentation & Environmental Monitoring
[Sponsored] The Cobrix 7501/7601 inline beverage analyser leverages advanced multi-parameter technology to enhance quality control in carbonated soft drink production.

Read more...









While every effort has been made to ensure the accuracy of the information contained herein, the publisher and its agents cannot be held responsible for any errors contained, or any loss incurred as a result. Articles published do not necessarily reflect the views of the publishers. The editor reserves the right to alter or cut copy. Articles submitted are deemed to have been cleared for publication. Advertisements and company contact details are published as provided by the advertiser. Technews Publishing (Pty) Ltd cannot be held responsible for the accuracy or veracity of supplied material.




© Technews Publishing (Pty) Ltd | All Rights Reserved