July 2013Analytical Instrumentation & Environmental Monitoring
The fire assay method is an accepted standard for determining the amount of precious metals, such as gold, silver and platinum, in a sample of ore. In mine assay laboratories therefore, reliable instruments are essential to allow accurate production forecasts by management.
Mettler Toledo’s range of Excellence balances offers accuracy, robustness and long-term reliability in the harsh weighing environments of precious metal mining companies and refineries. Specially designed accessories, and LabX One Click weighing solutions, make weighing secure and sample handling easier whilst providing fast results.
Weighing plays a crucial role in the fire assay process since errors in the measurement of the ore sample can have huge financial implications. To ensure accuracy, many assay laboratories use a high resolution analytical balance to determine the exact weight of the original sample, and a microbalance to weigh the final gold bead. With several samples being analysed at a time, the process requires much care to ensure that samples are tracked correctly.
Samples of ore from the field are prepared for analysis by crushing or grinding to obtain a uniform particle size. This is split into samples of approximately 30 g to be representative of the original larger sample. The samples are placed in a crucible and mixed with lead oxide and flux. The crucibles are then placed in a furnace at around 1000°C for a predetermined time, after which the molten contents are poured into a mould and allowed to cool. The lead in the sample ‘collects’ the gold which sinks to the bottom with the remaining contents forming a glassy slag on top.
The resulting lead ‘button’ is detached from the glassy slag and placed in a cupel. This small crucible is made of bone ash or magnesium oxide and can absorb up to twice its weight in lead. The cupels are placed back in the furnace. As the button melts, the lead is absorbed into the cupel to leave a small bead of gold.
The final weighing of this tiny bead of gold is critical to determine the gold content of the original sample with results typically in the order of 0,1 mg. Once the final gold bead is weighed, the percentage of gold content is calculated automatically and this determines if the ore is economically viable.
The fire assay method is a differential weighing procedure which can be customised and stored in the LabX software of the balance according to individual process requirements. Users can access the method directly with the LabX One Click shortcut on the balance touch screen and are guided through the process step-by-step.
The process allows the user to enter the number of samples and crucible IDs for easy sample identification. Results are saved automatically and confirming each step on the balance ensures operating procedures are followed precisely.
Reliability restored through systemic vibration analysis Wearcheck
Analytical Instrumentation & Environmental Monitoring
Condition monitoring specialist, WearCheck uses a variety of testing techniques to enhance reliability in machinery components and prevent failures.
Read more...Meteorological data logger with up to 32 analogue sensors Senseca
Analytical Instrumentation & Environmental Monitoring
Senseca has introduced its advanced data acquisition system for environmental monitoring, which has a universal data logger for up to 32 analogue, pulse and smart digital sensors.
Read more...Yokogawa’s free chlorine analyser is gold standard for water treatment utilities Yokogawa South Africa
Analytical Instrumentation & Environmental Monitoring
One of the key factors in ensuring safe drinking water is the accurate monitoring of free chlorine residuals. This is where advanced online analysers, such as Yokogawa’s FC800 free chlorine analyser, are becoming increasingly valuable for water treatment operators and municipal utilities.
Read more...Cooling tower bleed control
Analytical Instrumentation & Environmental Monitoring
Cooling towers rely on evaporation to remove heat, but this process also concentrates dissolved solids in the system. Left unmanaged, this buildup can lead to scaling, corrosion and fouling, reducing efficiency and increasing maintenance costs.
Read more...Importance of gas analysis in the petrochemical industry Elemental Analytics
Analytical Instrumentation & Environmental Monitoring
Gas analysis plays a critical role in petrochemical operations, supporting process optimisation, product quality and plant safety. As an experienced and expert gas analysis supplier, Elemental Analytics can provide the correct analyser and sample system package to meet individual plant requirements.
Read more...Filters for zero-alcohol wine Parker Hannifin - Sales Company South Africa
Analytical Instrumentation & Environmental Monitoring
The market for zero-alcohol wine is creating fresh opportunities for wine producers, but processing these products creates new contamination challenges. Technical support from an established filtration specialist, such as Parker, can help wineries in overcoming the challenges posed by the increased risk of contamination.
Read more...Remote monitoring solution for sewage plants ifm - South Africa
Analytical Instrumentation & Environmental Monitoring
With ifm’s remote monitoring solution, you can visualise the condition of the submersible pumps in your sewage plant and diagnose issues before they become serious problems.
Read more...Precision in every drop, powered by ICP technology Wearcheck
Analytical Instrumentation & Environmental Monitoring
Elemental profiling using Inductively Coupled Plasma – Optical Emission spectroscopy provides useful information on the chemical composition of lubricants.
Read more...A trusted oxygen analyser back in action Elemental Analytics
Analytical Instrumentation & Environmental Monitoring
After a period of discontinuation, Servomex’s Oxy 1810 oxygen analyser has officially returned.
While every effort has been made to ensure the accuracy of the information contained herein, the publisher and its agents cannot be held responsible for any errors contained, or any loss incurred as a result. Articles published do not necessarily reflect the views of the publishers. The editor reserves the right to alter or cut copy. Articles submitted are deemed to have been cleared for publication. Advertisements and company contact details are published as provided by the advertiser. Technews Publishing (Pty) Ltd cannot be held responsible for the accuracy or veracity of supplied material.