Analytical Instrumentation & Environmental Monitoring


Monitoring in the bleaching tower

October 2012 Analytical Instrumentation & Environmental Monitoring

Monitoring pH and ORP in the bleaching tower exposes pH electrodes to high temperatures and harsh conditions, shortening electrode life and leading to higher maintenance. Mettler Toledo offers its Ingold InPro 4801 SG flat glass pH electrode in a titanium hot-tap housing, along with the M800 transmitter, as a high-performance measuring point for use in the pulp and paper industry.

The InPro 4801 solution ground (SG) flat glass pH electrode is a low maintenance, dual-purpose electrode that is ideal for high temperature and high pressure environments. It is specially designed for operation in oxidant media and, due to its flat membrane glass, is much less susceptible to fouling. Moreover, it allows the measurement of both pH and redox simultaneously off the same electrode.

The M800 multi-parameter transmitter provides simultaneous monitoring of up to four in-line sensors with intelligent sensor management (ISM) technology for measurement of pH/ORP, optical DO, amperometric oxygen, conductivity, resistivity, dissolved ozone and flow.

The InPro 4801 SG electrode offers reliable measurements in oxidising media, strong acid or alkali solutions and sulphide-bearing media. The hot-tap style housing allows for continuous and safe access to the electrode, meaning that maintenance can be done without interrupting the process, despite the high operational pressure. In addition, the electrode performs for a long period of time before cleaning or calibration is required, thus reducing maintenance and replacement costs.

The InPro 4801 SG with a flat glass membrane and solution ground feature is the optimal choice for media with particles and fibres. Ground loops can be avoided with the solution ground, which can also be used as a diagnostic tool. The SG feature as an entire electrode body coating or as a measuring point on a pH-electrode, will improve grounding and effectively eliminate the risk of electrostatic interference. SG also improves advanced diagnostic functions, and makes parallel pH/redox measurement possible.

For more information contact Chris de Jager, Microsep, +27 (0)11 553 2300, chris.dejager@microsep.co.za, www.microsep.co.za



Credit(s)



Share this article:
Share via emailShare via LinkedInPrint this page

Further reading:

Portable fuel cleanliness analysis kit
January 2020 , Analytical Instrumentation & Environmental Monitoring
The Fleetguard FK36000 portable fuel cleanliness analysis kit is a reliable solution for testing fuel cleanliness in the field, according to Cummins Filtration mining sales manager Tinus Naude. Testing ...

Read more...
Focus on combustion and refinery applications
January 2020, Instrotech , Analytical Instrumentation & Environmental Monitoring
Instrotech now offers Keller’s range of intrinsically safe electronic pressure gauges for use in areas subject to gas explosion risks. The type approvals are compliant with the ATEX Explosion Protection ...

Read more...
ABB optimises efficient water usage
January 2020, ABB South Africa , Analytical Instrumentation & Environmental Monitoring
ABB has expanded its digital analytical measurement range of solutions with the launch of the AWT420 transmitter. The new four-wire, dual channel analytical instrument measures multiple parameters in ...

Read more...
Water analysis technology reduces downtime
January 2020, GHM Messtechnik SA , Analytical Instrumentation & Environmental Monitoring
In order to monitor the process of reverse osmosis and ensure that deposits do not clog up membranes and reduce system efficiency, Martens, a member of the GHM Group, has joined the forces with its Condix ...

Read more...
Mobile CO2 measuring device
November 2019, GHM Messtechnik SA , Analytical Instrumentation & Environmental Monitoring
The measurement of CO2 emissions throughout industry is a critical activity. Across many industries, leaks in equipment resulting from non-maintenance, mechanical damage or wear and tear can impact on ...

Read more...
Automated analysers for sulphate and chloride measurements
November 2019, Microsep , Analytical Instrumentation & Environmental Monitoring
Chlorides and sulphates cause pitting and stress corrosion in expensive power plant components, such as turbines and boilers, leading to extensive maintenance and unplanned shutdowns. Monitoring these ...

Read more...
Monitor and control sedimentation
October 2019, Morton Controls , Analytical Instrumentation & Environmental Monitoring
Quadbeam Technologies’ storm and wastewater sensor, the SWW, is a unique suspended solids sensor/turbidity meter. The intended use of the S20-SWW and S40-SWW sensors is the continuous monitoring of suspended ...

Read more...
LiquiSonic analysers in pulp and paper
October 2019 , Analytical Instrumentation & Environmental Monitoring
One of the important steps in the pulp and paper industry is the alkaline sulphate process, where lignin is separated from the fibrous material: due to economic and environmental reasons, the chemicals ...

Read more...
Reliable TDL analyser for gas analysis
September 2019, Microsep , Analytical Instrumentation & Environmental Monitoring
Tunable diode laser (TDL) spectroscopy is rapidly becoming the gas analysis technology of choice in industrial processes. Mettler Toledo Ingold offers the GPro 500 TDL Series, a versatile platform that ...

Read more...
Vaporising regulator increases the reliability of gas chromatograph analysers
September 2019, Emerson Automation Solutions , Analytical Instrumentation & Environmental Monitoring
With the Tescom 44-6800, Emerson has introduced a vaporising pressure reducing regulator for gas chromatograph analysers with the option to separate the regulator body from the electronic enclosure, without ...