Maintenance, Test & Measurement, Calibration


Hygienic limit switches for processes

February 2020 Maintenance, Test & Measurement, Calibration

Process and storage vessels incorporate limit switches to prevent overfilling of a tank or vessel (full indicator) or dry running of a pump (empty indicator). Anderson-Negele’s NCS series are ideally suited for the reliable measurement of limits in media with low water content, such as certain alcohols and cosmetics, providing universal application in bottling and pharmaceutical applications.

Capacitive working principle

Anderson-Negele level switches operate on the basis of the capacitive working principle. The measuring electrode, the medium and the conductive wall of the tank form an electrical capacitor influenced by three main factors: distance; area of the electrode surfaces; and type of medium between the electrodes.

The measuring electrode and the tank wall serve as the capacitor plates while the medium acts as the dielectric fluid. Due to the higher dielectric constant of the medium relative to air, the capacity increases when the electrode is immersed in the medium. Exposing the electrode has the opposite effect. The change in capacity is analysed by the level switch and converted to a corresponding switching command. The sensor outputs a 24 V DC signal (active output). The minimum and maximum (full/empty) switching functions can be swapped by reversing the polarity of the power supply. The capacitive working principle requires that the sensor tip, which is made of PEEK, be completely immersed in the medium. The advantage is that the sensor does not respond to foam or adherences and a signal is emitted only when the medium reaches the level. Capacitive measurement is most reliable when the dielectric conductivity and temperature of the medium are constant. Changes in the outer conditions are generally non-critical in media with high dielectric constant values.


Credit(s)



Share this article:
Share via emailShare via LinkedInPrint this page

Further reading:

Engineering partnership delivers longer life for vibrating feeders in mining
Maintenance, Test & Measurement, Calibration
: OST-Africa’s combination of VISAM vibrating motors and advanced rubber mounting technology has helped Euro Sales achieve a 30 to 40% increase in component life on vibrating feeders at several major mining operations, with zero mount failures in the first 12 months.

Read more...
When oil can’t take the heat
Maintenance, Test & Measurement, Calibration
Unlike the slow ageing of oxidation, thermal breakdown is the sudden chemical collapse of a lubricant under excessive heat. Steven Lumley of WearCheck explains how it happens, where it strikes, and how oil analysis detects it.

Read more...
Mini data loggers for temperature and humidity monitoring
Maintenance, Test & Measurement, Calibration
Testo’s range of four compact data loggers covers temperature and humidity monitoring for storage, refrigeration and transport applications, with USB-C or Bluetooth connectivity and capacity for up to 16 000 readings.

Read more...
Alternative fuels for cutting, brazing, soldering and heating
Maintenance, Test & Measurement, Calibration
Bolt and Engineering Distributors, as an authorised distributor for the Harris Products Group, is helping South African industries transition from acetylene to safer, more cost-effective alternative fuels for cutting, brazing, soldering and heating applications.

Read more...
Rethinking corrosion protection in process plants
Omniflex Remote Monitoring Specialists Maintenance, Test & Measurement, Calibration
Remote monitoring is changing how cathodic and anodic protection systems are managed in process plants, giving operators continuous visibility of corrosion protection performance and enabling more proactive maintenance decisions.

Read more...
Installation safety tester
Vepac Electronics Maintenance, Test & Measurement, Calibration
A combination measuring device for testing electrical installations, offering safety tests including RCD, voltage, loop, low-resistance, earth resistance and insulation checks via a 3,5-inch TFT colour display.

Read more...
Bringing predictive maintenance to the next level in the pulp and paper industry
Maintenance, Test & Measurement, Calibration
ennomotive has launched an international competition seeking innovative predictive maintenance solutions for conveyor belt systems, addressing a real operational challenge faced by pulp and paper company CMPC.

Read more...
Vibration sensor with CANopen interface for mobile machines
ifm - South Africa Maintenance, Test & Measurement, Calibration
ifm’s 3-axis VMB301 condition monitoring sensor integrates into the vehicle network via CANopen, delivering real-time bearing, vibration and temperature data to help mobile machines avoid costly damage and downtime.

Read more...
Linear regulated 2-channel laboratory power supply
Vepac Electronics Maintenance, Test & Measurement, Calibration
Vepac Electronics offers a dual-channel laboratory power supply built for safe, precise testing in laboratories and workshops.

Read more...
When oil gets old
Wearcheck Maintenance, Test & Measurement, Calibration
WearCheck explains how oxidation breaks down lubricating oils over time, and how routine oil analysis can catch the warning signs before equipment failure.

Read more...









While every effort has been made to ensure the accuracy of the information contained herein, the publisher and its agents cannot be held responsible for any errors contained, or any loss incurred as a result. Articles published do not necessarily reflect the views of the publishers. The editor reserves the right to alter or cut copy. Articles submitted are deemed to have been cleared for publication. Advertisements and company contact details are published as provided by the advertiser. Technews Publishing (Pty) Ltd cannot be held responsible for the accuracy or veracity of supplied material.