Electrical Power & Protection


Finding energy waste with power quality management

March 2024 Electrical Power & Protection

Saving energy and minimising energy waste are two of the most critical aspects of energy use. Energy saving means looking at your power consumption rates, and developing a power quality management energy-saving plan.

Benchmarking electrical energy consumption

The first step in developing a power quality management programme is benchmarking your current electrical energy consumption. Through an initial survey, you can look for quick and easy solutions to start with. Track areas that contribute to your energy usage outside significant assets, like supplementary electrical heating, lighting being left on, and computers not being switched off.

Once you’ve identified these quick wins, continue with more detailed studies. Run load studies on assets throughout the area using the Fluke 1777 three-phase power quality analyser. These measurements can show where you could see significant energy-saving opportunities, such as switching off some systems during the night.

Advanced power quality considerations

The next step in reducing energy consumption is to see where energy waste arises. One area is conductors. As current flows through conductors, some energy will turn into wasted energy as heat. What is the best solution? Consider the conductor sizing. Following the National Electric Code (NFPA 70 or NEC 100) gives guidance on the size of a conductor. The primary consideration for conductor sizing is ensuring the safe operation of the conductors with the most appropriate insulation. This depends on the length, cross-sectional area, and anticipated current rating required. This can provide minimised energy losses, typically 2% or less, and an acceptable voltage drop in the conductor. Some additional possibilities would be installing higher efficiency loads, and checking to see if motors might be oversized for the current application.

Wasted power

These codes and guidelines are fine for new installations, but don’t always work out ideally once the cabling installation is completed and the loads are installed. Over time, the equipment may change with additions or adjustments; moves and age can significantly affect waste energy. Key areas where energy waste may occur are related to your power quality, especially voltage regulation, harmonics, power factor, and unbalanced loads.

Voltage regulation works to reduce energy consumption in voltage-dependent loads. It reduces or controls the voltage levels within the equipment manufacturer’s specifications to return energy savings. As more efficient loads are installed at a transformer, the voltage in the system may rise or be incorrectly controlled. To catch voltage regulation issues, use a Fluke 1777 power quality analyser to look for transient voltages and voltage imbalance. Both issues can lead to failure, unplanned downtime, and expensive repairs.

Harmonics distort the voltage and current so that the ideal sine wave for voltage is not maintained. One of the most recognised effects of harmonics in electrical systems is the excess heat they create in the conductors carrying them. This results in overheating in phase and neutral conductors, known as ‘triplen harmonics’.

The additional heat causes cable runs, motor windings, and transformer issues. The overheating can cause significant damage or complete failure, either of which could lead to unplanned downtime and expensive repairs. To measure and diagnose harmonics, use a Fluke 1770 series three-phase power quality analyser.

The additional heat due to an unbalanced load causes issues with cable runs, motor windings, and transformers. The overheating can cause significant damage or complete failure, either of which could lead to unplanned downtime and expensive repairs. To measure and diagnose harmonics, use a Fluke 1770 series three-phase power quality analyser.

Once power quality studies reveal areas where energy is being wasted, you can take steps to fix the issues:

• Set up a preventive maintenance routine so you can continue to measure against your benchmark and catch issues as they arise.

• Install harmonic filters on loads that add to your facility’s harmonic distortion.

• Address the sources of unbalance. This may mean setting up a repair or replacement schedule for large motors with mechanical unbalance issues.

• Mitigate unbalanced load issues. In some cases, this may mean adjusting single-phase loads to be more equally distributed across the phases.

• Replace blown fuses where necessary.

Product: https://bit.ly/3HsyTZJ


Credit(s)



Share this article:
Share via emailShare via LinkedInPrint this page

Further reading:

Navigating solar energy adoption
Electrical Power & Protection
Although South Africa’s enhanced solar tax rebate has ended, solar and energy storage solutions remain accessible and achievable. By taking a proactive and strategic approach, businesses can successfully lower their operational costs, mitigate power outages, and secure long-term energy independence.

Read more...
As wind energy gains momentum, lack of grid infrastructure remains a bottleneck
Electrical Power & Protection
Interest in wind energy has gained significant momentum in South Africa, opening up new opportunities for investment. However, lack of grid infrastructure could prove to be a stumbling block in unlocking this potential.

Read more...
Portable appliance tester
Vepac Electronics Electrical Power & Protection
The new appliance tester from Vepac is the ideal tool for testing the safety of electrical appliances in accordance with DGUV regulation 3 and BetrSichV. It enables the precise measurement of protective conductor or touch current using the equivalent leakage current method.

Read more...
Is sustainability enough any more?
Electrical Power & Protection
With the planet’s resources stretched to the brink and no signs of improvement, it is time we look beyond sustainability and explore regenerative thinking and design.

Read more...
A simple guide to understanding the importance of IP ratings
Electrical Power & Protection
When selecting electrical products for industrial, commercial or even domestic use, it is crucial to consider how well they can withstand environmental factors like dust and water. This is where ingress protection (IP) ratings come into play.

Read more...
A milestone in electrical safety
ABB South Africa Electrical Power & Protection
Celebrating a milestone in electrical safety, ABB proudly marks the 100-year anniversary of its revolutionary Miniature Circuit Breaker.

Read more...
The power of water
Editor's Choice Electrical Power & Protection
The Alpenglow Hy4 is the world’s first water-based hydrogen combustion engine, offering a convincing alternative to traditional battery-electric vehicles and established hydrogen fuel cell designs.

Read more...
Optimising purification for green hydrogen production
Parker Hannifin - Sales Company South Africa Editor's Choice Electrical Power & Protection
Parker Hannifin delivers advanced purification and thermal management components that enhance green hydrogen production.

Read more...
A new chapter in geothermal engineering
Editor's Choice Electrical Power & Protection
The town of Geretsried in southern Germany has become a focal point in the global shift toward renewable energy. While the world’s attention often turns to wind turbines and solar panels, a quieter but no less powerful force is at work deep beneath the surface, geothermal energy.

Read more...
Harnessing the ocean with wave energy
Editor's Choice Electrical Power & Protection
Wave energy is emerging as one of the most promising yet underutilised renewable sources. Tapping into the rhythmic, predictable power of ocean waves, this technology offers a clean, reliable alternative to fossil fuels and a valuable complement to wind and solar energy.

Read more...









While every effort has been made to ensure the accuracy of the information contained herein, the publisher and its agents cannot be held responsible for any errors contained, or any loss incurred as a result. Articles published do not necessarily reflect the views of the publishers. The editor reserves the right to alter or cut copy. Articles submitted are deemed to have been cleared for publication. Advertisements and company contact details are published as provided by the advertiser. Technews Publishing (Pty) Ltd cannot be held responsible for the accuracy or veracity of supplied material.




© Technews Publishing (Pty) Ltd | All Rights Reserved