Electrical Power & Protection


Finding energy waste with power quality management

March 2024 Electrical Power & Protection

Saving energy and minimising energy waste are two of the most critical aspects of energy use. Energy saving means looking at your power consumption rates, and developing a power quality management energy-saving plan.

Benchmarking electrical energy consumption

The first step in developing a power quality management programme is benchmarking your current electrical energy consumption. Through an initial survey, you can look for quick and easy solutions to start with. Track areas that contribute to your energy usage outside significant assets, like supplementary electrical heating, lighting being left on, and computers not being switched off.

Once you’ve identified these quick wins, continue with more detailed studies. Run load studies on assets throughout the area using the Fluke 1777 three-phase power quality analyser. These measurements can show where you could see significant energy-saving opportunities, such as switching off some systems during the night.

Advanced power quality considerations

The next step in reducing energy consumption is to see where energy waste arises. One area is conductors. As current flows through conductors, some energy will turn into wasted energy as heat. What is the best solution? Consider the conductor sizing. Following the National Electric Code (NFPA 70 or NEC 100) gives guidance on the size of a conductor. The primary consideration for conductor sizing is ensuring the safe operation of the conductors with the most appropriate insulation. This depends on the length, cross-sectional area, and anticipated current rating required. This can provide minimised energy losses, typically 2% or less, and an acceptable voltage drop in the conductor. Some additional possibilities would be installing higher efficiency loads, and checking to see if motors might be oversized for the current application.

Wasted power

These codes and guidelines are fine for new installations, but don’t always work out ideally once the cabling installation is completed and the loads are installed. Over time, the equipment may change with additions or adjustments; moves and age can significantly affect waste energy. Key areas where energy waste may occur are related to your power quality, especially voltage regulation, harmonics, power factor, and unbalanced loads.

Voltage regulation works to reduce energy consumption in voltage-dependent loads. It reduces or controls the voltage levels within the equipment manufacturer’s specifications to return energy savings. As more efficient loads are installed at a transformer, the voltage in the system may rise or be incorrectly controlled. To catch voltage regulation issues, use a Fluke 1777 power quality analyser to look for transient voltages and voltage imbalance. Both issues can lead to failure, unplanned downtime, and expensive repairs.

Harmonics distort the voltage and current so that the ideal sine wave for voltage is not maintained. One of the most recognised effects of harmonics in electrical systems is the excess heat they create in the conductors carrying them. This results in overheating in phase and neutral conductors, known as ‘triplen harmonics’.

The additional heat causes cable runs, motor windings, and transformer issues. The overheating can cause significant damage or complete failure, either of which could lead to unplanned downtime and expensive repairs. To measure and diagnose harmonics, use a Fluke 1770 series three-phase power quality analyser.

The additional heat due to an unbalanced load causes issues with cable runs, motor windings, and transformers. The overheating can cause significant damage or complete failure, either of which could lead to unplanned downtime and expensive repairs. To measure and diagnose harmonics, use a Fluke 1770 series three-phase power quality analyser.

Once power quality studies reveal areas where energy is being wasted, you can take steps to fix the issues:

• Set up a preventive maintenance routine so you can continue to measure against your benchmark and catch issues as they arise.

• Install harmonic filters on loads that add to your facility’s harmonic distortion.

• Address the sources of unbalance. This may mean setting up a repair or replacement schedule for large motors with mechanical unbalance issues.

• Mitigate unbalanced load issues. In some cases, this may mean adjusting single-phase loads to be more equally distributed across the phases.

• Replace blown fuses where necessary.

Product: https://bit.ly/3HsyTZJ


Credit(s)



Share this article:
Share via emailShare via LinkedInPrint this page

Further reading:

Power supply with scalability optimised
Schneider Electric South Africa Electrical Power & Protection
Schneider Electric has introduced the Easy UPS 3-Phase Modular to the South African marketplace. This robust uninterruptible power supply (UPS) is designed to protect critical loads while offering third-party verified Live Swap functionality.

Read more...
Prioritising arc flash safety
Comtest Electrical Power & Protection
Comtest has developed a range of thermal imaging and wireless testing tools from Fluke, designed to ensure safety is the top priority for engineers working in potentially dangerous arc flash zones.

Read more...
Monitoring the voltage drop in cables
Turck Banner Southern Africa Electrical Power & Protection
With its new M12Plus connectors, Turck Banner is directly shifting the condition monitoring of cables subject to severe stress to the connection technology. The connectors, which come with voltage and current monitoring and a Bluetooth chip, enable measured voltage and current values to be sent wirelessly to a controller.

Read more...
Mesh networks: a multidirectional electrical superhighway
Schneider Electric South Africa Electrical Power & Protection
Today, many power industry stakeholders are faced with mounting requirements for improved grid reliability, resilience and distribution efficiency. It’s a challenge which requires power service providers to rethink their infrastructure. Enter mesh networks, which can overcome the limitations of traditional star networks.

Read more...
Versatile flexible copper busbar
Electrical Power & Protection
Referro Systems specialises in the supply and support of industrial electrical, automation and global software and hardware brands, and is now able to offer the Cubic range of Cu-Flex flexible copper busbars.

Read more...
Trafo Power Solutions upgrades DRC mine transformers
Electrical Power & Protection
With its experience in Africa and its agility in executing projects rapidly, Trafo Power Solutions is supplying three mini-substations and two transformers to a copper-zinc mine in the Democratic Republic of Congo.

Read more...
Acquiring locally-manufactured transformers
ACTOM Electrical Machines Electrical Power & Protection
Speed and efficiency are of the essence in the fast-evolving power generation and distribution space; but a significant challenge is the prolonged lead times associated with acquiring transformers – key components in any electrical infrastructure.

Read more...
Seaward testers power PV specialists
Comtest Electrical Power & Protection
One of Asia’s leading clean energy specialists, Solarvest, uses the latest electrical safety test equipment to ensure the solar photovoltaic (PV) installations it services and maintains operate at peak performance levels.

Read more...
Multi-purpose contact block
Electrical Power & Protection
The TME catalogue has been expanded to include products from Schlegel. This German, family-owned company has been specialising in the production of high-quality electromechanical components for almost 80 years.

Read more...
ACTOM supplies transformer units to Kamoa Copper Mine
ACTOM Electrical Machines Electrical Power & Protection
ACTOM Distribution Transformers, recently secured an order for the supply of its neutral electromagnetic couplers, with earthing resistors, and an auxiliary transformer) to Kamoa Copper Mine in the DRC.

Read more...