In addition to BACnet/IP, Beckhoff now also supports BACnet MS/TP (Master Slave/Token Passing) with the EL6861 EtherCAT Terminal. This serial interface can be used to directly control and monitor BACnet-compatible field devices, such as pumps, drives, frequency converters or similar, as sub-bus systems, without the need for additional gateways or routers. Up to 64 devices with RS-485 low power transceivers can be connected. In addition, several terminals can be operated in parallel to scale the number of MS/TP channels that can be supported.
Using the 1-channel BACnet MS/TP interface, hardware and engineering costs can be significantly reduced since configuration is performed centrally in the TwinCAT System Manager and external devices, such as routers or gateways, do not need to be connected. Combined with the BACnet MS/TP driver integrated within TwinCAT automation software, the terminal implements the BACnet protocol in compliance with Revision 12. The terminal can also be used locally without routing to the BACnet/IP network.
The RS-485 interface guarantees high interference immunity through electrically isolated signal transmission. The EL6861 provides 1 x 5 V DC at 20 mA (electrically isolated, short-circuit-proof) from the E-bus supply for use with the bias resistors (network bias).
Suppression and safety solutions for fire and gas in mission-critical industries
Fieldbus & Industrial Networking
By representing world-leading brands and focusing on fully integrated, certified systems, HMA South Africa is positioning itself as a trusted partner in fire detection, suppression and explosion-proof safety solutions across the continent.
Read more...Integrating fire alarm systems into building management systems Beckhoff Automation
Fieldbus & Industrial Networking
Fire alarm systems work independently of the building automation system. Schrack Seconet has developed a flexible gateway using ultra-compact industrial PCs and TwinCAT from Beckhoff, which can be used to flexibly convert a customer-specific communication protocol to a wide range of transmission standards.
Read more...Fire and gas suppression solutions for mission-critical industries
Fieldbus & Industrial Networking
By representing world-leading brands and focusing on fully integrated, certified systems, HMA South Africa is positioning itself as a trusted partner in fire detection, suppression and explosion-proof safety solutions across the continent.
Read more...The future of manufacturing
Fieldbus & Industrial Networking
Industrial automation is evolving at an unprecedented pace. At the forefront of this transformation is the Siemens SIMATIC ET 200SP HA Distributed I/O system. This is a flexible and scalable distributed I/O system for modern signal transfer from the field to the control level.
Read more...Time-sensitive networking RJ Connect
Editor's Choice Fieldbus & Industrial Networking
In this article, we will explore what is driving the rise of time-sensitive networking, how it is reshaping industrial efficiency, the challenges when deploying this technology, and ways to tackle these challenges.
Read more...Loop Signature 30: Nonlinearity in control loops (Part 1) Michael Brown Control Engineering
Editor's Choice Fieldbus & Industrial Networking
If nonlinearity occurs it means that if one is to carry on controlling with the same response to changes in load or setpoint, then the tuning of the controller will also need to be adjusted to meet the new conditions.
Read more...PC-based control regulates innovative dehumidifiers Beckhoff Automation
Fieldbus & Industrial Networking
Swedish company, Airwatergreen is breaking new ground in the dehumidification of air in industrial buildings and warehouses. The patented CVP technology reduces energy requirements and ensures an indoor climate that prevents corrosion and mould growth. PC-based control from Beckhoff regulates this innovative process.
While every effort has been made to ensure the accuracy of the information contained herein, the publisher and its agents cannot be held responsible for any errors contained, or any loss incurred as a result. Articles published do not necessarily reflect the views of the publishers. The editor reserves the right to alter or cut copy. Articles submitted are deemed to have been cleared for publication. Advertisements and company contact details are published as provided by the advertiser. Technews Publishing (Pty) Ltd cannot be held responsible for the accuracy or veracity of supplied material.