Analytical Instrumentation & Environmental Monitoring


Discharge limits under control

July 2016 Analytical Instrumentation & Environmental Monitoring

Electroplating and tanning companies generate contaminated wastewater that must be treated before it can be released into the sewage system. These companies often operate their own wastewater treatment plants to reduce the contaminants to limits that meet the stipulated discharge values. To achieve these values for chromate, they require absolutely reliable, precise chromate (Cr(VI)) monitoring and full documentation of the measured values. Liquiline System CA80CR offers optimum support for these companies. It uses the standardised colorimetric diphenylcarbazide method ensuring compliance with discharge regulations. The analyser also features detailed logbooks that provide continuous documentation of the chromate values.

Detailed monitoring of chromate reduction

Chromium VI compounds are highly toxic and must not end up in surface water under any circumstances. Liquiline System CA80CR enables effective online monitoring of the treatment process and thus allows precise supervision of the integrity of ion exchangers and membrane filtration systems. It also supports optimised dosing of reducing agents such as sodium hydrogen sulphite and helps plant operators to rectify process disturbances remotely via its advanced diagnostics using modern communication protocols. Liquiline System increases the safety of the chromate reduction process.

Precise chromate measurement in potable water

Liquiline System CA80CR also offers waterworks the security that no chromium(VI) will end up in the distribution network and supports them in providing detailed documentation of the chromate values to the water authorities. The World Health Organization (WHO) stipulates a total chromium limit of 0,05 mg/l for potable water.

Low reagent consumption and simplified maintenance

Operating cost of a colorimetric analyser is dependent on the consumption of reagent and calibration standards over its lifetime. Liquiline System is designed with highly precise dispensers for reagent dosing to guarantee reduced consumption. The reagents of Liquiline System CA80CR last up to 3,5 months at a measuring interval of 10 minutes. Automatic cleaning and calibration functions ensure that the analyser and its sample preparation work reliably and without manual intervention over a longer period of time. Maintenance tasks can be carried out easily and with minimal tools, reducing maintenance costs and increasing process uptime.

Easy operation and commissioning

Liquiline System shares the user-friendly operation that plant personnel already know from other online analysis parameters such as pH or turbidity, as it has the same hardware and software interfaces operating errors are virtually eliminated. The analyser can be easily upgraded to a complete measuring station by connecting Memosens sensors. Liquiline System then adopts the transmitter functions, which reduces the total number of devices in the plant. Memosens communication also allows full control of the sample preparation systems by the Liquiline System analyser, speeding up commissioning and operation. The CAT860 and CAT820 sample preparation systems are perfectly adapted to the rough conditions in industrial wastewater as they feature chemically stable membrane pumps and hoses and corrosion-resistant ceramic filters.

Liquiline System chromate analysers and sample preparation systems help managers of electroplating and tanning plants to comply with strict discharge limits and keep discharge fees under control, while making daily life easier for operators http://bit.ly/1oBJgiI.

For more information contact Jan Swart, Endress+Hauser, +27 (0)11 262 8000, [email protected], www.za.endress.com



Credit(s)



Share this article:
Share via emailShare via LinkedInPrint this page

Further reading:

Matching HVAC to the real demands of buildings and processes
Analytical Instrumentation & Environmental Monitoring
Industrial Climate Engineering director, Alin Gomes explains why effective HVAC goes beyond specifying equipment on capacity, covering load profiling, ventilation requirements, heat recovery and turnkey delivery for specialised manufacturing and processing environments.

Read more...
How SCE approaches sensor selection for critical environments
Specialised Climate Engineering Analytical Instrumentation & Environmental Monitoring
Specifying the right sensor for a critical climate involves far more than matching a datasheet accuracy figure. As an authorised Vaisala HVAC partner, SCE explains how understanding the environment, the measurement purpose and sensor placement determines effective climate control.

Read more...
Changing gas quality calls for smarter combustion control
Analytical Instrumentation & Environmental Monitoring
As South Africa prepares for a transition from declining Mozambican natural gas to a proposed methane-rich bridge, LNG, industrial users can no longer assume a constant Wobbe Index and calorific value. The compact RMG RGQ 5 provides fast, plant-level gas-quality data to support approved burner and engine settings.

Read more...
Getting the chemistry right
Analytical Instrumentation & Environmental Monitoring
Grace’s European production site has relied on analogue compression load cells from Minebea Intec for decades, with the long-proven measurement concept now serving as the reference for new silo projects as the company expands its capacity.

Read more...
Why measurement matters in smelting
Endress+Hauser South Africa Analytical Instrumentation & Environmental Monitoring
South African smelters returning to operation after energy constraints face new demands for tighter control, better visibility and environmental compliance. Endress+Hauser explains how modern measurement technology supports safer, more efficient furnace operation and local beneficiation.

Read more...
Sun tracking with pinpoint precision
Senseca Analytical Instrumentation & Environmental Monitoring
Senseca has introduced the SEMS-2000 solar energy measurement system, a 2-axis solar tracker with pinpoint sun-pointing accuracy that automatically monitors direct, global and diffuse irradiance for unattended outdoor solar installations.

Read more...
AMETEK expands 993X gas analyser series with explosion-proof enclosures
Analytical Instrumentation & Environmental Monitoring
AMETEK Process Instruments has added ATEX and IECEx Zone 1-certified explosion-proof enclosures to its 993X series of gas analysers, enabling reliable installation in Zone 1 hazardous locations where purge gas is unavailable.

Read more...
Endress+Hauser to showcase measurement and automation solutions at Electra Mining
Endress+Hauser South Africa News
Endress+Hauser will demonstrate process automation, measurement technology and digital transformation solutions at Electra Mining Africa 2026, with interactive displays and expert guidance for mining, minerals, water and wastewater industries.

Read more...
Why medical device leak testing matters for South Africa's MedTech future
ATEQ South Africa Analytical Instrumentation & Environmental Monitoring
As South Africa works to grow local medical technology manufacturing, non-destructive leak and flow testing is becoming a strategic quality assurance tool, helping manufacturers verify device integrity, meet regulatory requirements and improve production efficiency.

Read more...
Moving forward with reverse osmosis
Analytical Instrumentation & Environmental Monitoring
Rising water costs and pressure on infrastructure are changing the way industries view reverse osmosis. G-Chem Aquacare is developing tailored, containerised solutions that make the technology more accessible for South African industry.

Read more...









While every effort has been made to ensure the accuracy of the information contained herein, the publisher and its agents cannot be held responsible for any errors contained, or any loss incurred as a result. Articles published do not necessarily reflect the views of the publishers. The editor reserves the right to alter or cut copy. Articles submitted are deemed to have been cleared for publication. Advertisements and company contact details are published as provided by the advertiser. Technews Publishing (Pty) Ltd cannot be held responsible for the accuracy or veracity of supplied material.




© Technews Publishing (Pty) Ltd | All Rights Reserved