Electrical Power & Protection


Zest WEG Group’s protection systems

December 2015 Electrical Power & Protection

The continuous pursuit for improvement and cost reduction in industry has seen a rapid evolution in the development of electric motor control and protection systems. “To ensure that we meet all the needs of industry in this regard, as well as keeping abreast of the latest trends and developments, the Zest WEG Group has introduced its range of RW_E electronic motor protection overload relays, to complement the range of smart relays,” says switchgear manager Stephen Cook.

The relays are designed for increased reliability in terms of the protection of low-voltage three-phase motors in sinusoidal 50/60 Hz networks where reliability, low power dissipation and ease of maintenance are critical requirements. They have been developed in accordance with the IEC 60947-4-1 and UL 60947-4-1A (UL 508) international standards.

RW_E Electronic overload relays are highly reliable devices intended to protect motors, controllers and branch circuit conductors against phase failures and overloads that can result in overheating. These critical products play a vital role in overall system performance and efficiency and are designed to protect three-phase and single-phase AC motors.

The electronic overload relay has no power contacts and therefore cannot disconnect the motor by itself. Instead, motor overloads or phase failures increase the motor current, which in turn trips the mechanism and switches the auxiliary contacts. When wired properly in series with the coil of the contactor, these auxiliary contacts will de-energise the contactor in the event of an overload.

This means the contactor itself disconnects the power supply to the motor, halting its operation. Another handy feature is that, once tripped, the relay will only reset once the motor has cooled down, preventing costly damage. The relays are also temperature compensated, which means that the trip point is not affected by temperature and it performs consistently at the same current value.

In order to ensure rapid tripping in the case of phase loss, and thereby protecting the motor and avoiding costly repairs or additional maintenance, the WEG RW_E relays include phase failure sensitivity protection as a standard feature. They can be mounted directly onto the WEG CWB and CWM contactor ranges, which make for highly reliable and flexible motor starting units.

For more information contact Kirsten Larkan, Zest WEG Group, +27 (0)11 723 6000, [email protected], www.zest.co.za



Credit(s)



Share this article:
Share via emailShare via LinkedInPrint this page

Further reading:

South African businesses can alleviate energy price crisis
Electrical Power & Protection
While grid instability remains a concern, the immediate and most critical driver of South African commercial and industrial investment in renewable energy is the escalating cost of electricity.

Read more...
Real-time modelling is the key to a resilient, bi-directional energy grid
Schneider Electric South Africa Electrical Power & Protection
Utilities and municipalities are facing a challenge as the country’s legacy power grid, engineered for one-way energy delivery from centralised suppliers to end-users, must rapidly evolve to meet a new paradigm.

Read more...
Shielding data centre growth from the looming power crunch
Schneider Electric South Africa Electrical Power & Protection
Today’s digital economy is placing unprecedented strain on the power grid. The good news is that these challenges are not insurmountable. By adopting proactive strategies such as alternative power sources, infrastructure planning and software, operators can secure capacity, build resilient facilities and scale sustainably.

Read more...
Circuit breaker innovations
Schneider Electric South Africa Electrical Power & Protection
Recent advancements in circuit breaker technology have seen a major step forward in setting new standards for efficiency and sustainability in data centres, industrial and commercial infrastructure.

Read more...
Common battery tester errors and what they mean
Comtest Electrical Power & Protection
Battery testers help quickly assess battery health, diagnose issues, and determine whether a battery needs a charge or replacement. This guide covers some of the most common battery tester errors, what they mean, and what can cause them.

Read more...
Cathodic protection design considerations that influence ESG outcomes
Omniflex Remote Monitoring Specialists Electrical Power & Protection
Major infrastructure like wharves, bridges, pipelines and tanks are at constant risk of corrosion. David Celine, managing director of cathodic protection specialist Omniflex, explains how CP system design can support ESG commitments, while simultaneously lowering costs and improving maintenance capabilities.

Read more...
Africa’s digital future – building critical power infrastructure for data centre leadership
Electrical Power & Protection
Africa’s digital economy is growing rapidly, and countries like South Africa, Nigeria and Kenya are leading the way. However, a major challenge remains. Sustainable and reliable power systems must form the backbone of Africa’s digital growth to ensure lasting success.

Read more...
Recovering condensate and waste heat
Electrical Power & Protection
According to Associated Energy Services, strong partnerships with thermal energy users optimise opportunities to benefit from condensate return. waste heat recovery and the prevention of system contamination.

Read more...
Quantum engine powered by particle entanglement
Electrical Power & Protection
In a landmark achievement that signals a new era in energy research, a team of physicists in China has carried out the first successful test of a quantum engine powered by particle entanglement. This technological breakthrough represents a fundamental shift in our approach to energy production.

Read more...
Advancing sustainability in South Africa’s fruit industry
Schneider Electric South Africa Electrical Power & Protection
Schneider Electric, together with Technoserve Medium Voltage, has implemented its advanced SF6-free MV switchgear at Two-a-Day situated in Grabouw in the Overberg district.

Read more...









While every effort has been made to ensure the accuracy of the information contained herein, the publisher and its agents cannot be held responsible for any errors contained, or any loss incurred as a result. Articles published do not necessarily reflect the views of the publishers. The editor reserves the right to alter or cut copy. Articles submitted are deemed to have been cleared for publication. Advertisements and company contact details are published as provided by the advertiser. Technews Publishing (Pty) Ltd cannot be held responsible for the accuracy or veracity of supplied material.




© Technews Publishing (Pty) Ltd | All Rights Reserved