Maintenance, Test & Measurement, Calibration


Combined sample probe for simultaneous measurements

October 2001 Maintenance, Test & Measurement, Calibration

The D-RX 250 combined sample probe from Durag, is capable of measuring dust concentration, volume flow, absolute pressure and temperature simultaneously. It is designed for continuous monitoring of dust concentration in flue gas ducts, dust extraction pipes and similar applications.

The transmitter is mounted at the measuring point and with transmission of the raw data via the bus interface, the mounting location of the operating and evaluation unit can be positioned up to 100 m from the measuring point. Alternatively, the raw data can also be computed by an emission computer or a process control system.

Dust concentration is determined according to the tribo-electric measuring principle, while the volume flow measurement operates on the differential pressure principle. The absolute pressure in the flue gas is sampled in one chamber of the probe and measured by a piezo-resistive pressure transmitter. Temperature is measured in a separate chamber within the probe, directly in the core flow of the flue gas by a Pt100 resistance thermometer.

The transmitter is connected to the probe and modifies the tribo-electric current, the temperature sensor's signal, absolute pressure, as well as the volumetric flow value from the differential pressure transducer to raw values and transmits these over a bus interface to the control and evaluation unit.

These raw values are received by the operating and evaluation unit, which computes the normalised dust concentration from them. Measurements are available as 20 mA current signals for dust concentration, volume flow, temperature and absolute pressure together with a series of associated status signals.

Operation is menu-guided using four keys and a four-line display. The measurements are displayed in various menus, and for improved readability, measurements can be shown in large characters.

The probe is not suitable for use after an electrostatic precipitator in wet stack gases, or where abrasive dust particles may damage the probe.

OEN Enterprises

(011) 792 2859

[email protected]

www.oenenterprises.co.za





Share this article:
Share via emailShare via LinkedInPrint this page

Further reading:

Infrared thermometers for electrical, industrial and HVAC applications
Comtest Maintenance, Test & Measurement, Calibration
: Comtest, distributor of Fluke test and measurement equipment, explains how handheld infrared thermometers are transforming maintenance in electrical, industrial and HVAC environments, with three measurement strategies and a wide range of practical applications.

Read more...
Reverse-engineering legacy industrial gearbox parts
Maintenance, Test & Measurement, Calibration
WEG Africa’s turbine workshop uses 3D scanning technology to reverse-engineer components for legacy gearboxes, turbines and compressors, enabling equipment to run for decades after OEM support and spare parts have dried up.

Read more...
Unlocking ICCP remote monitoring
Omniflex Remote Monitoring Specialists Maintenance, Test & Measurement, Calibration
Cathodic protection keeps buried and submerged pipelines safe from corrosion, but verifying it traditionally means costly, hazardous manual site visits. Omniflex explains how a retrofit module brings remote monitoring to ageing transformer rectifiers without replacing functional infrastructure.

Read more...
Microdieseling – the explosions you never hear
Maintenance, Test & Measurement, Calibration
Microdieseling is a pressure-induced thermal degradation mechanism in which entrained air bubbles are compressed so rapidly that the surrounding oil ignites, producing soot, varnish and sludge. WearCheck explains how it happens, why the damage varies, and how oil analysis detects it.

Read more...
Electrostatic spark discharge – when static strikes back
Wearcheck Maintenance, Test & Measurement, Calibration
WearCheck technical manager, Steven Lumley explains how static electricity accumulates in modern low-conductivity lubricants, why compact system designs and fine filtration make ESD more likely, and how to recognise the degradation it leaves behind.

Read more...
High-speed cameras for crash testing
Horne Technologies Maintenance, Test & Measurement, Calibration
Vision Research has expanded its Phantom C-series with two cameras optimised for crash and safety testing, offering 4 and 8 megapixel sensors rated to 170G, up to 1180 frames per second, and Phantom Academy application training planned for South Africa next year.

Read more...
SKF extends remanufacturing expertise to bearing clearance modification
SKF South Africa Maintenance, Test & Measurement, Calibration
Using its clearance modification expertise, SKF helped a mining equipment OEM salvage spherical roller bearing inventory that would otherwise have been scrapped, confirming a new capability within its remanufacturing services and avoiding redundant procurement.

Read more...
When maintenance-system compliance starts replacing plant reliability
Wearcheck Maintenance, Test & Measurement, Calibration
WearCheck ARC division manager, Annemie Willer argues that the greatest threat to effective maintenance is no longer a lack of technology, but the gradual replacement of technical judgement by CMMS compliance, leaving no one owning the machine.

Read more...
Automatic lubrication systems drive mobile mine machine reliability and uptime
SKF South Africa Maintenance, Test & Measurement, Calibration
SKF’s Lincoln P203 progressive lubrication systems are improving reliability and uptime on mobile machines at a Zambian gold mine, with installation of 45 units completing by October 2026.

Read more...
Nitration: the acid you didn’t see coming
Wearcheck Maintenance, Test & Measurement, Calibration
Nitration is as destructive as oxidation in many engines but far less understood. WearCheck technical manager, Steven Lumley explains how nitrogen oxide gases degrade lubricants, why the process is difficult to detect, and what oil analysis can reveal before damage occurs.

Read more...









While every effort has been made to ensure the accuracy of the information contained herein, the publisher and its agents cannot be held responsible for any errors contained, or any loss incurred as a result. Articles published do not necessarily reflect the views of the publishers. The editor reserves the right to alter or cut copy. Articles submitted are deemed to have been cleared for publication. Advertisements and company contact details are published as provided by the advertiser. Technews Publishing (Pty) Ltd cannot be held responsible for the accuracy or veracity of supplied material.




© Technews Publishing (Pty) Ltd | All Rights Reserved