Fieldbus & Industrial Networking


Liberate stranded information and diagnostics with industrial wireless

September 2013 Fieldbus & Industrial Networking

Many plants have hundreds or even thousands of HART devices, but not all of these are delivering the full range of process variables, calibration, maintenance and diagnostic data to plant operators and maintenance departments. This is because they have no means of delivering that data to the control room. One reason is that some legacy control systems are analogue, meaning they have no access to the digital HART data thus preventing operators from taking full advantage of the device intelligence. To achieve maximum insight, the existing control system must be upgraded by installing HART I/O interface cards and software modules.

Control systems that are HART compatible will always be able to interpret the primary variable from the HART field device (HART systems will also be able to get digital data and not just primary variable), but analogue systems will not be able to understand the digital data, for example, the device tag and descriptor fields. The analogue systems are unable to read the secondary or tertiary variables from the field device (if it is a multivariable transmitter) or the diagnostic data. To overcome this problem a HART multiplexer can be applied. The multiplexer acts as a gateway that routes communications between field devices and the asset management system, without compromising the integrity of the control system. However, installing a multiplexer is not a simple procedure as it requires the rewiring of marshalling cabinets. This can pose a risk to current operations and be both time-consuming and costly. Constraints on capital expenditure can often make this solution cost prohibitive.

WirelessHART adaptors

The availability of WirelessHART adaptors, such as Emerson’s Smart Wireless THUM adapter, presents a more convenient, lower cost and low risk alternative to installing multiplexers. A WirelessHART adaptor is a device that can be retrofitted on any two or four-wire HART instrument, allowing the device to transmit up to four variables and status information at a user-configurable update rate. The data is sent wirelessly, via a gateway to an asset management system, where the information can be interrogated by operators and maintenance staff. This negates the need for the installation of a multiplexer and is an easy way to access the field intelligence already installed in the plant. It also enables new measurements to be added wirelessly.

This functionality is very useful for process level applications. When connected to level devices, the WirelessHART adaptor opens up the possibility of transmitting a range of secondary variables in addition to the primary variable: level. The WirelessHART adaptor enables users to access the stranded HART measurement and diagnostic information, which can be used to make improvements in quality, safety, availability, operations and enables reductions in maintenance costs.

Scheduling maintenance

Currently there are huge inefficiencies in the way many process level devices are maintained, including routine checks and preventive maintenance on equipment when it’s not needed. If the infrastructure is not in place to communicate the digital HART data to the control room or maintenance area, regular trips to the field may be the only option. This not only takes time, but often requires work permits and special personal protective equipment (PPE) for hazardous areas. A WirelessHART adaptor enables the process level device to be fully managed and monitored remotely. By gaining real-time access to advanced diagnostics about the health of equipment, it is possible to move from reactive to proactive maintenance, lowering costs and saving time.

Combining a WirelessHART adaptor with a process level device enables operators to monitor the additional HART variables that give an insight into process efficiency and the condition of the device. Parameters such as signal strength and signal quality can be transmitted as secondary process variables and these can be used by operators to monitor the health and performance of the process level device, as well as getting insight to their processes. For example, the signal quality metrics function of the Rosemount 5300 guided wave radar can be used to determine when there is build up on the probe and the point at which it needs to be cleaned. When the signal quality falls below preset limits, it is possible to transmit an alarm indicating that maintenance is required.

The WirelessHART adaptor also provides information about the performance of a process level device. Emerson’s Rosemount 5300 guided wave radar and 5400 non-contacting radar devices can both transmit data to produce an echo curve graphic to any host that supports enhanced EDDLs. The echo curve is an important troubleshooting tool as it provides full insight to the installation echoes and how they behave over time. Knowing how well the device is performing prevents unnecessary trips to the field, allows you to schedule maintenance, and of course ensures that inaccurate measurements are not taking place that could affect the quality of the process.

Enabling new measurement points

It’s not just applications involving existing installed process level HART devices that benefit from the availability of a WirelessHART adaptor. WirelessHART adaptors enable process level devices to be applied to areas of the plant that previously were not possible, such as where no communications cabling is available and the cost of installing new cabling is prohibitive. A particular area where there is a need for additional level devices to meet environmental requirement is within overfill protection applications. Where previously manual checks were sufficient, now automated continuous monitoring is a requirement. Often tanks are located remotely and the cost of installing wired devices is very high. Here, wireless presents the obvious solution.

To eliminate manual measurements an Emerson customer installed a Smart Wireless THUM adaptor on two guided wave radar devices. The existing gauging process was unreliable, leading to a risk of spills. The manual measurement method exposed personnel to the fuel twice per day and climbing the tank to take the measurement was also dangerous. In addition, the customer had no capability to integrate a level signal into the control system at this site. With the THUM adaptor in place the customer has access to more frequent and accurate measurements than before and this was accomplished without the need to run new signal wires to the devices.

The ability to transmit multivariable data further broadens the possible process level applications. For example, when a WirelessHART adaptor is attached to a guided wave radar device that previously only had an analogue connection to the control system, it is now possible to access both level and interface level measurements. A volume measurement can also be obtained, either calculated based on ideal tank shapes or a customised strapping table. Other variables that can be transmitted include the distance to level, interface distance, and upper layer thickness. Emerson’s Rosemount 5300 series in conjunction with a WirelessHART adaptor offers the opportunity to transmit all these variables as well as the upper and lower volumes.

Conclusion

Whether users want to install a new measurement point without the high cost of wiring or would like access to stranded diagnostics and device health information from existing HART instruments, the ability to connect IEC 62591 WirelessHART adaptors with process level devices is enabling the full range of HART functions to be accessed in a cost effective way.

For more information contact Mark Tapson, Emerson Process Management, +27 (0)11 451 3700, [email protected], www.emersonprocess.com



Credit(s)



Share this article:
Share via emailShare via LinkedInPrint this page

Further reading:

Comprehensive solutions for the food and beverage sector
RS South Africa Fieldbus & Industrial Networking
RS South Africa is reinforcing its commitment to the country’s dynamic food and beverage sector, backed by a comprehensive portfolio of over 800 000 products, extensive technical expertise and end-to-end service capabilities.

Read more...
Case History 198: Cascade control overcomes valve problems
Michael Brown Control Engineering Fieldbus & Industrial Networking
A large petrochemical refinery asked me to perform an audit on several critical base layer control loops. This article deals with a problem found on a valve controlling the flow of fuel to a heat exchanger.

Read more...
Improved networking technology for fire and gas detection
Omniflex Remote Monitoring Specialists Fieldbus & Industrial Networking
Critical alarm and event management technology supplier, Omniflex has worked with the South African Nuclear Energy Corporation to upgrade equipment providing digital and analogue signals for its safety critical fire and gas alarm systems.

Read more...
PC-based control for fertiliser
Beckhoff Automation Editor's Choice Fieldbus & Industrial Networking
On a farm in the USA, valuable ammonia is extracted from slurry and processed into ammonium sulphate. NSI Byosis has transformed this complex process into a flexible modular system. This modular approach requires an automation solution with flexible scalability in both hardware and software, which this Dutch company has found in PC-based control from Beckhoff.

Read more...
Loop signature 28: Things to consider when tuning.
Michael Brown Control Engineering Editor's Choice Fieldbus & Industrial Networking
I was giving a course at a remote mine in the middle of the Namibian desert. We were discussing tuning responses, and as I always do on my courses, I mentioned that in my opinion ¼ amplitude damped tuning is not desirable, and is in fact not good.

Read more...
How industrial network design impacts ESG commitments
Omniflex Remote Monitoring Specialists Fieldbus & Industrial Networking
In safety-critical industries like nuclear, petrochemical and oil and gas, installing a new industrial cable network is an extremely complicated task. Gary Bradshaw, a director of industrial network specialist, Omniflex explains why this is often unnecessary as plants are likely to have existing cabling capable of being used to create new industrial networks.

Read more...
Minelert industrial solutions
Fieldbus & Industrial Networking
Profitek provides cutting-edge industrial networking, automation and IoT solutions for harsh environments.

Read more...
The ultimate industrial LoRaWAN gateway
Fieldbus & Industrial Networking
The GW-101-LORA-4AO is the ultimate industrial LoRaWAN gateway, combining advanced IoT connectivity with expandable I/O.

Read more...
Industrial Power-over-Ethernet DC injector
Fieldbus & Industrial Networking
The ML-NET-INJECT series sets the standard for industrial PoE, featuring IP68-rated RJ45 connectors and military-grade components for extreme reliability.

Read more...
Industrial networking IO-Link
Fieldbus & Industrial Networking
Balluff IO-Link Network Modules enable seamless, intelligent communication between sensors, actuators and control systems. Designed for Industry 4.0, they provide real-time data exchange, simplify wiring, and enhance diagnostics.

Read more...