Maintenance, Test & Measurement, Calibration


Humidity generator for RH probe calibration

January 2018 Maintenance, Test & Measurement, Calibration

Fluke Calibration has on offer the 5128A RHapid-Cal Humidity Generator, a portable, versatile humidity generator for calibrating a large variety of probes and loggers in the field or laboratory. The 5128A is ideal for corporate and independent calibration laboratories where humidity measurement is critical to prevent spoilage of products, including pharmaceuticals, medical devices, semiconductors, chemicals, and food production.

The instrument is lightweight and compact so technicians can easily take it to the field for thorough, reliable multi-point calibration of humidity probes and loggers. In the laboratory, it reduces calibration time by at least 33 percent compared to traditional two-pressure humidity generators, which are slower to respond to humidity and temperature set point changes.

The 5128A delivers:

• Best-in-class system accuracy of 1,0% RH for dependable humidity probe calibration.

• Rapid humidity and temperature stabilisation time for high calibration throughput.

• Rate of change for temperature increase is typically 10°C/minute; for temperature decrease 1,5°C/minute.

• Rate of change for humidity increase is typically 10% RH/minute; for decrease 5% RH/minute.

• A six-point calibration can be done in two hours.

Easy maintenance

The 5128A RHapid-Cal comes standard with an ISO 17025 accredited system calibration and is backed by Fluke Calibration’s world-class metrology and support. A front-loading desiccant cartridge can be easily changed by removing the front cap and sliding in a new one. Only clean distilled water is required to operate the 5128A.

For more information contact Comtest, +27 (0)10 595 1821, [email protected], www.comtest.co.za



Credit(s)



Share this article:
Share via emailShare via LinkedInPrint this page

Further reading:

Common battery tester errors and what they mean
Comtest Electrical Power & Protection
Battery testers help quickly assess battery health, diagnose issues, and determine whether a battery needs a charge or replacement. This guide covers some of the most common battery tester errors, what they mean, and what can cause them.

Read more...
OEM-standard repairs for industrial gear units
Maintenance, Test & Measurement, Calibration
BMG, the official OEM for Hansen gearboxes, is authorised to repair Hansen industrial gear units in strict accordance with the manufacturer’s documented procedures, preserving the design tolerances and operational reliability required in demanding industrial environments.

Read more...
The smart choice for test and measurement solutions
RS South Africa Maintenance, Test & Measurement, Calibration
As the demand for precision and efficiency continues to grow across industries, RS PRO, the own brand of RS, provides a complete portfolio of test and measurement equipment engineered to meet the highest standards of performance, safety and value.

Read more...
Multifunction installation tester speeds up testing by 30%
Comtest Electrical Power & Protection
Comtest has launched the new Fluke 1670 Series Multifunction Installation Tester, which can cut the amount of time electricians and maintenance technicians spend producing reports by up to 50%,

Read more...
Revolutionising fault location and maximising solar production
Comtest Electrical Power & Protection
Comtest has on offer the Fluke GFL-1500 solar ground fault locator, a frontline troubleshooting tool that helps technicians pinpoint active ground faults in solar photovoltaic systems.

Read more...
New frequency counter with 10 digits of resolution
Comtest Maintenance, Test & Measurement, Calibration
B&K Precisio has a new series of universal frequency counters designed for a wide range of frequency measurement applications.

Read more...
Ground-breaking battery tester
Comtest Electrical Power & Protection
Midtronics offers the proven MVT handheld battery tester. This revolutionary tool, powered by MDX-AI, is set to redefine the standards of battery diagnostics and testing in the automotive industry.

Read more...
Verification using Heartbeat Technology is a breeze
Maintenance, Test & Measurement, Calibration
Heartbeat Technology reflects Endress+Hauser’s long-term commitment to enhancing measurement reliability and efficiency across a growing product portfolio.

Read more...
Clog-resistant nozzle for powerful stationary tank cleaning
Maintenance, Test & Measurement, Calibration
As EXAIR and BETE continue to build on a strong partnership, EXAIR has recently added a selection of BETE products to the site, including the innovative BETE HydroClaw tank and vessel cleaning nozzle.

Read more...
Maintenance and health of battery storage systems
Comtest Electrical Power & Protection
How to maintain batteries.

Read more...









While every effort has been made to ensure the accuracy of the information contained herein, the publisher and its agents cannot be held responsible for any errors contained, or any loss incurred as a result. Articles published do not necessarily reflect the views of the publishers. The editor reserves the right to alter or cut copy. Articles submitted are deemed to have been cleared for publication. Advertisements and company contact details are published as provided by the advertiser. Technews Publishing (Pty) Ltd cannot be held responsible for the accuracy or veracity of supplied material.




© Technews Publishing (Pty) Ltd | All Rights Reserved