Sensors & Transducers


Humidity measurement in poultry farms

August 2017 Sensors & Transducers

Incubation

Eggs are kept in the incubator for a total of 18 days. There are two schools of thought on the correct humidity level to use during this stage. The most popular condition for incubating the eggs is 53% RH @ 37°C. Towards the end of the incubation period, the eggs will start to release CO2, which builds up in the incubator. Valves open to vent this excess and keep the CO2 close to atmospheric levels, which has the side effect of venting water vapour and reducing the humidity level inside, therefore humidifiers are used to compensate for this and keep the level around the required 53%.

Some customers see better uniformity of chicks when they are incubated in a higher humidity initially – 60% or higher in some instances (still at 37°C). They still vent the excess CO2 towards the end of the incubation cycle, but do not replace the water vapour lost at this stage.

If the egg tray is not completely full, then the level of humidification will need to be higher to maintain the required 53% level.

Measurement

The measurement in this environment is fairly clean and after 18 days the eggs are moved to another room. Cleaning methods will vary from site to site, but typically are less invasive. The sensors here typically will have a longer lifetime than those in other areas of the farm.

Hatching

Following the 18 days of incubation, the eggs are moved to the hatcher, where they spend a total of three days. This cycle also begins with a condition of 53% RH @ 37°C. As soon as the chicks begin to hatch, the humidity level naturally increases, up to around 80%. This higher humidity actually assists the other chicks by making the shells slightly softer, allowing them to hatch more easily.

As the chicks hatch, CO2 levels also increase, so ventilation and humidification starts. Once all the chicks are hatched, humidity will be maintained around 60%.

As in the incubator, if the egg tray is not completely full then the level of humidification will need to be higher to maintain the required 53% level.

Measurement

This is a more demanding measurement as the hatching is a messy process. After the chicks are removed, the room will be decontaminated by pressure-washing with a mixture of water and disinfectant. It is this stage which is particularly damaging to the sensor, which should ideally be removed, or at least covered up while this cleaning process is taking place.

Adult chickens

Normal body temperature for chickens is 41,5°C, however this will fluctuate depending on environmental temperature. Maintaining a constant body temperature is not a problem when air temperature is at least 10-15 degrees less than body temperature, but air movement is critical. A bird can only give off heat to its environment if the temperature of that environment is cooler than the bird. If heat produced by the birds is not moved away from them and out of the poultry house quickly, it will be more difficult for them to avoid heat stress.

The ambient temperature should be maintained at <around25°C to avoid stressing the chickens, but more importantly, the environmental temperature should be kept as stable as possible. Fluctuations in the temperature, especially in combination with high relative humidity, will be more stressful to the birds than a high ambient temperature alone.

Measurement

This is the toughest measurement of the three as any sensors installed into the living environment or on the air outlets will experience drift over time, due to the NH3 content in the air. There is also a significant amount of dust, which can cause premature failure on sensors with inadequate filtration.

By far the best location for controlling this environment is on the fresh air inlet.

Cleaning will also periodically take place in this environment, and the same precautions should be followed as in the hatchery, the sensors should be either removed or covered to prevent irreversible damage.

Michell’s HydroSmart HS3 probe

The probe is proven to be a suitable product for withstanding the conditions described above, if the following precautions are adhered to:

• Probes should be mounted in a vertical orientation.

• Probes should always be covered, or ideally removed completely, during decontamination/cleaning cycles.

• Probes should never be cleaned with any kind of solvent, detergent or pressurised water, they should just be wiped down with a damp cloth.

For more information contact Instrotech, +27 (0)10 595 1831, [email protected], www.instrotech.co.za



Credit(s)



Share this article:
Share via emailShare via LinkedInPrint this page

Further reading:

Groundwater level measurement using LoRa module
Instrotech Level Measurement & Control
Monitoring groundwater levels across large industrial sites is critical. Salzgitter Digital Solution was tasked with developing a fully automated and digital monitoring system using Long Range Wide Area Network technology.

Read more...
Distance sensor for confined spaces
ifm - South Africa Sensors & Transducers
The O6D100 from ifm has been designed as a powerful all-rounder for typical applications in object detection, distance measurement and positioning.

Read more...
Long-range laser distance measuring sensor
Vepac Electronics Sensors & Transducers
The MS-100A is a long-range laser distance measuring sensor with a range of 150 to 1000 mm. This sensor excels in applications requiring extended measurement capabilities, such as quality control and logistics.

Read more...
Listening for damage to wind turbines
Sensors & Transducers
The Fraunhofer Institute for Integrated Circuits, working in concert with the Fraunhofer Institute for Wind Energy Systems, has developed a solution that can be used to identify cracks and breakage inside wind turbine blades remotely at an early stage.

Read more...
Infrared solutions for glass manufacturing challenges
Instrotech Temperature Measurement
In the glass industry, infrared temperature monitoring is crucial for maintaining product quality and process efficiency. Instrotech has infrared sensors and cameras which provide non-contact temperature measurements, making them ideal for these high-temperature environments.

Read more...
Verification using Heartbeat Technology is a breeze
Endress+Hauser South Africa Sensors & Transducers
Heartbeat Technology reflects Endress+Hauser’s long-term commitment to enhancing measurement reliability and efficiency across a growing product portfolio.

Read more...
Enhancing efficiency and reliability in the energy sector
VEGA Controls SA Sensors & Transducers
VEGA offers practical, reliable solutions through specialised measuring instruments and deep industry know-how, all tailored to help energy companies keep costs under control while meeting strict regulatory standards.

Read more...
Condition monitoring for hydroelectric plants
ifm - South Africa Sensors & Transducers
The energy company Compagnia Valdostana delle Acque generates electricity in the region’s 32 hydroelectric power plants with a total capacity of over 900 MW. Vibration sensors from ifm monitor the maintenance requirements of the turbines and power generators at all times.

Read more...
Senix sensors provide flood warnings
Instrotech Flow Measurement & Control
To create the world’s most sophisticated flood monitoring and forecasting system, the US State of Iowa’s Flood Centre (IFC) uses more than 200 Senix ToughSonic 30 and ToughSonic 50 ultrasonic sensors to measure water levels in streams across the state.

Read more...
Precision sensing for water treatment
ifm - South Africa Sensors & Transducers
ifm electronic has introduced two next-generation sensors designed for South Africa’s bulk and wastewater sector, engineered to withstand harsh environments and deliver long-term reliability.

Read more...









While every effort has been made to ensure the accuracy of the information contained herein, the publisher and its agents cannot be held responsible for any errors contained, or any loss incurred as a result. Articles published do not necessarily reflect the views of the publishers. The editor reserves the right to alter or cut copy. Articles submitted are deemed to have been cleared for publication. Advertisements and company contact details are published as provided by the advertiser. Technews Publishing (Pty) Ltd cannot be held responsible for the accuracy or veracity of supplied material.




© Technews Publishing (Pty) Ltd | All Rights Reserved