Fieldbus & Industrial Networking


Westermo solution maximises ­availability of Spanish solar power plants

March 2016 Fieldbus & Industrial Networking

For a solar power plant to be profitable, it must produce at maximum capacity at all times. All parts of the plant must work as planned and there must be backup systems should unexpected problems arise. Helping to meet this requirement, Westermo was commissioned to create a reliable data communications network, which included 290 industrial Ethernet switches, to maximise systems for availability at the La Florida and La Dehesa thermal solar power plants in south-western Spain.

“Plant availability is essential. Any interruptions to the communications affect our ability to generate power,” explained Renovables SAMCA’s César Labarga, project manager for solar field control system. “We therefore needed an extremely reliable data network to support the plant control systems, and this is what was provided by Westermo.”

Scope of the project

La Florida and La Dehesa are both concentrating solar power (CSP) plants, owned and operated by Renovables SAMCA. The plants are identical in size, construction and function. Each has a capacity of 49,9 MWe and supplies electricity for more than 45 000 homes. A CSP plant uses large mirrors to capture the sun’s rays and focus the beam on a pipe containing oil. The heated oil is then pumped to the power plant, where the heat is converted into steam to drive a turbine. Each plant has more than 225 000 mirrors, grouped in 672 solar collectors which are continually adjusted via a control unit to follow the sun’s path to maximise efficiency. Should data communications between the collectors and the control room stop, the collectors are automatically set to safe mode, which means they stop transferring energy. It is therefore essential to have a reliable data network.

Labarga put it simply: “We needed a reliable system that could guarantee full availability, even in the event of a network link failure.”

In addition to the critical requirements of network reliability and availability, Renovables SAMCA also needed the network equipment installed quickly. A number of suppliers and solutions were considered, but as Labarga explained: “Of all the companies we talked to, Westermo’s proposition was the simplest and best solution. The network topology offered the greatest reliability and the support offered by Westermo gave us great confidence in the solution.”

The network solution

Westermo’s network topology was designed around a central dual Gigabit fibre optic ring using 25 Westermo RedFox managed industrial Ethernet switches. Nine sub rings consisting of 120 Westermo Lynx switches were added to reach out to the different parts of the plant. Each sub ring was configured to create a primary and a backup link. All individual rings in the network run the Westermo FRNT ring protocol which enables 20 ms reconfiguration of the network in the event of link (cable or switch) failure. Because La Florida and La Dehesa are identical, the same solution could be installed at each plant.

Renovables SAMCA wanted a quick and smooth installation process. To support this Westermo built, configured and tested the entire network in advance, in its laboratory in Sweden. The two complete networks, including all of the 290 switches, were mounted on a giant ‘network wall’, enabling the full configuration and test prior to installation at the two plants.

Labarga and a colleague from Renovables SAMCA were invited to Westermo’s facility in Sweden to receive a short training session on the equipment and to oversee the FAT (Factory Acceptance Test). This enabled them to evaluate the solution and make sure it met their requirements. The network was put through thousands of tests, with errors simulated to enable the network configuration to be fully proved. The solution was extremely reliable with very fast error recovery.

“Having Westermo configure all devices beforehand was essential to this project. We needed a solution that was both easy to install and very reliable. The preconfigured Westermo solution was thoroughly tested and worked perfectly,” said Labarga.

The Westermo devices were carefully labelled before they were sent to the customer to help simplify the installation process. Each switch was placed exactly where it would be installed prior to the installation process, which was extremely efficient with all 290 switches installed and both networks up and running in less than three hours.

Ray Lock, from the Westermo Network Applications team said, “This was a very well thought out solution, right from the choice of products and network design through to the network testing and implementation.”

When performing maintenance at the power plants the normal procedure requires that parts of the communications network be shut down periodically. This continually tests the resilience of the network configuration, but since the equipment was successfully installed there have been no reported problems or serious incidents.

“Having installed the Westermo devices successfully, we are very happy with how the network is performing. It is a really stable and reliable solution and the continued support from Westermo has ensured that we have had no problems,” concluded Labarga.

For more information contact Bob Petrie, Throughput Technologies, +27 (0)11 705 2497, [email protected], www.throughput.co.za



Credit(s)



Share this article:
Share via emailShare via LinkedInPrint this page

Further reading:

Why secure industrial communication depends on deployment as well
Fieldbus & Industrial Networking
The Industrial Security Harmonisation Group has released a joint industry perspective highlighting a critical truth in industrial cybersecurity: secure communication is not determined by protocols alone, but by how they are deployed and managed in real-world environments.

Read more...
A single platform for all automation functions
Beckhoff Automation Fieldbus & Industrial Networking
The introduction of TwinCAT in 1996 marked a decisive evolutionary step for PC-based control. Today, the TwinCAT platform combines all automation functions in a strictly deterministic real-time environment, from PLC and motion control through CNC and measurement technology and beyond, to vision, robotics and pioneering AI tools.

Read more...
Loop signature Part 2-4: Feedforward Control: Part 3
Michael Brown Control Engineering Editor's Choice Fieldbus & Industrial Networking
In the previous articles in this series, the basic theory behind feedforward control was discussed, and it was also shown how to apply feedforward in practice. In this article, it will be shown how well feedforward can work in practice by giving a couple of examples.

Read more...
Control Station and Dimension Software partner to connect control performance monitoring with enterprise operations intelligence
Fieldbus & Industrial Networking
Control Station has entered into a strategic technology partnership with Dimension Software, a leading provider of industrial operations management platforms. The collaboration connects Control Station’s PlantESP control loop performance monitoring platform with Dimension Software’s Asset Intellect operations intelligence environment, enabling manufacturers to operationalise control performance insights across their organisations.

Read more...
PCIe digitiser cards for optimal GHz signal acquisition and analysis
Vepac Electronics Fieldbus & Industrial Networking
The addition of two new PCIe Digitiser cards from Spectrum Instrumentation extends the company’s flagship M5i series to deliver optimal GHz signal acquisition and analysis capabilities.

Read more...
Precise, synchronised control for automated steel mesh handling system
Fieldbus & Industrial Networking
Automation specialist Hambi Maschinenbau has developed a world-first system that automates the cutting, handling and stacking of heavy reinforcing steel mesh – a task that previously required up to six human operators.

Read more...
Loop signature Part 2-3: Feedforward Control: Part 2
Michael Brown Control Engineering Editor's Choice Fieldbus & Industrial Networking
Feedforward control tuning is not nearly as critical as feedback tuning, and fairly simple models are usually fine for the purpose in hand.

Read more...
Upgrading radiological surveillance systems in nuclear facilities
Omniflex Remote Monitoring Specialists Fieldbus & Industrial Networking
Nuclear plant operators face an uncomfortable reality. Many of the control and monitoring systems still in use today were never designed to support the full operational lifespan of the facilities they serve.

Read more...
Next-level CAN Software enables easy access to CAN XL
Industrial Data Xchange (IDX) Fieldbus & Industrial Networking
With the release of its PCAN-Explorer 7, PEAK delivers a major update that adds full support for CAN XL, multiple symbol files per connection, Python scripting and flexible licensing including floating licenses.

Read more...
Loop signature Part 2-2: Feedforward Control: Part 1
Michael Brown Control Engineering Fieldbus & Industrial Networking
Feedforward control is a powerful technique that can dramatically improve control variance in cases where load changes cause big deviations from setpoint and the actual process dynamics are too slow to allow the feedback controller to operate fast enough to catch these disturbances.

Read more...









While every effort has been made to ensure the accuracy of the information contained herein, the publisher and its agents cannot be held responsible for any errors contained, or any loss incurred as a result. Articles published do not necessarily reflect the views of the publishers. The editor reserves the right to alter or cut copy. Articles submitted are deemed to have been cleared for publication. Advertisements and company contact details are published as provided by the advertiser. Technews Publishing (Pty) Ltd cannot be held responsible for the accuracy or veracity of supplied material.




© Technews Publishing (Pty) Ltd | All Rights Reserved