The OLR 84 S protection relay from NewElec, when mounted on a motor circuit, eliminates impact torque conditions which can result in broken chains, damaged screw conveyors, broken couplings and even damaged gearboxes.
The OLR 84 S relay has two settings. The first designates the total start time for the given motor in seconds through a range up to 50 s while the second designates the load trip threshold. The latter setting is percentage calibrated from 30 to 120% of the selected CT ratio XXX:1. It is necessary for the user to select an appropriate ring CT that will cover the expected trip threshold current. A general rule is that if the motor load maximum current is x A, the user must select a current transformer where 3x A is about mid-scale. The reason for this is that a stall or jam condition usually manifests itself at about three times motor full load when the motor develops an output torque in the region of 2,5 to 3 times its normal rated torque. This output torque will then be amplified through a factor dependent on the gearbox ratio.
The OLR 84 S permits the starting current for the motor start but will cause a trip in 100 ms if the motor load suddenly exceeds the upper trip threshold where the motor enters a stall condition after the starting sequence. In doing so, it will interrupt the supply to the motor by means of the main holding contactor and prevent mechanical fractures in the production process.
Africa’s digital future – building critical power infrastructure for data centre leadership
Electrical Power & Protection
Africa’s digital economy is growing rapidly, and countries like South Africa, Nigeria and Kenya are leading the way. However, a major challenge remains. Sustainable and reliable power systems must form the backbone of Africa’s digital growth to ensure lasting success.
Read more...Recovering condensate and waste heat
Electrical Power & Protection
According to Associated Energy Services, strong partnerships with thermal energy users optimise opportunities to benefit from condensate return. waste heat recovery and the prevention of system contamination.
Read more...Quantum engine powered by particle entanglement
Electrical Power & Protection
In a landmark achievement that signals a new era in energy research, a team of physicists in China has carried out the first successful test of a quantum engine powered by particle entanglement. This technological breakthrough represents a fundamental shift in our approach to energy production.
Read more...Advancing sustainability in South Africa’s fruit industry Schneider Electric South Africa
Electrical Power & Protection
Schneider Electric, together with Technoserve Medium Voltage, has implemented its advanced SF6-free MV switchgear at Two-a-Day situated in Grabouw in the Overberg district.
Read more...The power of the three-phase UPS
Electrical Power & Protection
In critical sectors such as mining, manufacturing and data centres, power quality is just as important as supply. This is where three-phase uninterruptible power supply (UPS) systems become indispensable.
Read more...Transformer reliability matters in data centres
Electrical Power & Protection
Data centres are the backbone of modern business and government operations. The first step to maintaining power stability is establishing transformer reliability.
Read more...Powering SA’s municipalities
Electrical Power & Protection
Municipalities are well positioned to shape South Africa’s energy future, a trend that attracted hundreds of professionals and vendors, including WEG, to the 71st Convention of the Association of Municipal Electricity Utilities.
Read more...Multifunction installation tester speeds up testing by 30% Comtest
Electrical Power & Protection
Comtest has launched the new Fluke 1670 Series Multifunction Installation Tester, which can cut the amount of time electricians and maintenance technicians spend producing reports by up to 50%,
While every effort has been made to ensure the accuracy of the information contained herein, the publisher and its agents cannot be held responsible for any errors contained, or any loss incurred as a result. Articles published do not necessarily reflect the views of the publishers. The editor reserves the right to alter or cut copy. Articles submitted are deemed to have been cleared for publication. Advertisements and company contact details are published as provided by the advertiser. Technews Publishing (Pty) Ltd cannot be held responsible for the accuracy or veracity of supplied material.