Fieldbus & Industrial Networking


Symmetricom delivers precise time for smart grid

April 2013 Fieldbus & Industrial Networking

Symmetricom has announced a new timing solution that meets the stringent microsecond accuracy requirements of smart grid substations. Specifically designed for operations such as wide area measurement systems and travelling wave fault locators, the Symmetricom SyncServer SGC-1500 Smart Grid Clock offers power utility companies accurate, secure and reliable timing and synchronisation for mission-critical operations. This means energy providers will be able to mitigate outages with real-time monitoring for grid stress, frequency instability, voltage instability and reliability margins.

The smart grid has brought about power technology advancements that fundamentally change substation operations. Power equipment and its data networks are shifting from simple, reactive control and reporting to proactive, real-time management and operations control. Thus, advanced synchronisation and timing are now more critical than ever and this is precisely what the SGC-1500 is designed to address, enabling power equipment to operate more efficiently and closer to its operational limits. For example, one microsecond accuracy is required by the phase measurement unit (PMU) for real-time network situational awareness and overall operational efficiency. Without accurate time stamps, PMU data has limited value. For power utility companies, this translates into enhanced network utilisation rates as well as smarter management and mixing of renewable and traditional power sources.

Power and utility companies are increasingly looking to source the latest technology innovations in order to modernise their infrastructure. Over the past three years, companies that have developed smart grid products have experienced a boost in venture capital investment. These are all data-intensive applications that rely heavily on precise timing and synchronisation, as well as more advanced analytics to process these vast streams of new information.

“The smart grid architecture and related standards require a new approach to timing distribution across the overall network,” says Manish Gupta, vice president of marketing and business development for Symmetricom. “Symmetricom brings extensive experience in delivering precise time to the communications, government and enterprise markets. Serving the power utility telecom network over the past 10 years, it is ideally positioned to meet the emerging timing requirements of the smart grid.”

The SyncServer SGC-1500 meets key requirements of smart grid substations, including:

* Microsecond accuracy and resiliency: referencing GPS satellite signals, the Symmetricom Smart Grid Clock distributes timing with microsecond accuracy over the local area network (LAN) using the IEEE 1588 v2 Precision Time Protocol (PTP) Power Profile or IRIG-B time code.

* IEC 61850 – the International Electrotechnical Commission’s (IEC) standard for the design of electrical substation automation, which requires microsecond timing to identify and mitigate a potential fault condition in real-time. This standard also identifies important electrical hardening requirements for substation environments.

* NERC CIP – the North American Electric Reliability Corporation (NERC) reliability and security standards for critical infrastructure protection (CIP), which calls for high strength security protocols.

The SyncServer SGC-1500 delivers additional industry leading capabilities such as a built-in IEEE 1588 v2 telecom profile input option. This enables the clock to derive time from the communications wide area network (WAN), thus eliminating the need to have GPS at every substation and PMU. The Rubidium atomic clock option offers holdover capability in the event of GPS disruption. These options result in a highly cost effective and resilient solution for power utilities.



Credit(s)



Share this article:
Share via emailShare via LinkedInPrint this page

Further reading:

Beckhoff expands economy drive system
Beckhoff Automation Fieldbus & Industrial Networking
: Beckhoff’s new AM1000 servomotor joins the company’s economy drive system. The compact, powerful motor and the AX1000 servo drive provide users with a perfectly coordinated, cost-optimised drive system.

Read more...
CC-Link IE Field supports egg carton production
Fieldbus & Industrial Networking
Huhtamaki’s Franeker plant in the Netherlands manufactures more than 11 million egg cartons every week using recycled paper. To support its highly automated lines, the site has begun upgrading its automation systems from older serial network standards to CC-Link IE Field, an open industrial Ethernet technology that offers faster performance due to gigabit bandwidth and better diagnostics.

Read more...
Ultra-compact industrial PCs exploit advances in CPU technology
Beckhoff Automation Fieldbus & Industrial Networking
Beckhoff’s C60xx scalable series of ultra-compact industrial PCs combines high computing power in an extremely compact format with a wide range of options for installation in the control cabinet.

Read more...
How to protect your industrial network
RJ Connect Editor's Choice Fieldbus & Industrial Networking
Network security is no longer a matter of preventing hacking or data breaches. Traditional defence mechanisms for perimeter protection may not fully address internal threats or device-level vulnerabilities alone.

Read more...
High-speed precision and simplified architecture for slicing systems
Fieldbus & Industrial Networking
When KFT Food Machinery needed a way to support ultra-fast, multi-axis motion control in its slicer range, it turned to CC-Link IE TSN – the open industrial Ethernet technology from the CC-Link Partner Association (CLPA).

Read more...
Precise, synchronised control for automated steel mesh handling system
Fieldbus & Industrial Networking
Automation specialist Hambi Maschinenbau has developed a world-first system that automates the cutting, handling and stacking of heavy reinforcing steel mesh – a task that previously required up to six human operators.

Read more...
Loop Signature Part 2-1: Loop signatures and process transfer functions
Michael Brown Control Engineering Fieldbus & Industrial Networking
The previous series of loop signature articles dealt with the basics of control loop optimisation, and concentrated on troubleshooting and ‘SWAG’ tuning of simple processes. In this new series, consideration will be given to dealing practically with more difficult issues like interactive processes, and with processes with much more complex dynamics.

Read more...
Smart and seamlessly integrated I/O upgrade
Beckhoff Automation Fieldbus & Industrial Networking
Beckhoff’s entire portfolio of EtherCAT terminals is now undergoing a technological upgrade while remaining fully compatible with the existing series.

Read more...
Introduction to Part 2 loop signatures and process transfer functions
Fieldbus & Industrial Networking
The previous series of loop signature articles dealt with the basics of control loop optimisation, and concentrated on troubleshooting and ‘SWAG’ tuning of simple processes. In this new series, consideration will be given to dealing practically with more difficult issues like interactive processes, and with processes with much more complex dynamics.

Read more...
Siemens sets new standards in drive technology
Fieldbus & Industrial Networking
Siemens is setting new standards in industrial drive technology with the launch of its new high-performance drive system, Sinamics S220. This offers a seamless and innovative drive system with comprehensive simulation and analysis capabilities and advanced connectivity features that enable full integration into digital work processes.

Read more...









While every effort has been made to ensure the accuracy of the information contained herein, the publisher and its agents cannot be held responsible for any errors contained, or any loss incurred as a result. Articles published do not necessarily reflect the views of the publishers. The editor reserves the right to alter or cut copy. Articles submitted are deemed to have been cleared for publication. Advertisements and company contact details are published as provided by the advertiser. Technews Publishing (Pty) Ltd cannot be held responsible for the accuracy or veracity of supplied material.




© Technews Publishing (Pty) Ltd | All Rights Reserved