The new EP9214 power distributor box enables the local distribution and switching off of the power supply, providing the ability to exceed the power limitation specified by typical M8 plug connectors. This innovative I/O solution also provides complete diagnostics and control functionality for up to eight 24 VDC branch circuits per power box.
The IP67-rated EtherCAT Box I/O modules typically use M8 plug connectors for supplying power, which according to the plug connector standard are only suitable for a maximum amperage of 4 A. Therefore, it may not be possible to simply loop the supply through when modules have a large number of outputs. A further limitation concerns the cables: if the cables from the control cabinet to the machine are long, an excessive voltage drop can occur at higher currents. As a result, the 24 VDC can no longer be maintained and the modules or connected sensors/actuators may no longer work properly.
The EP9214 power box is the ideal solution for these challenges. Equipped with larger plug connectors, it maintains a total current of 16 A for each control and peripheral voltage with cable cross-sections of 1,5 and 2,5 mm². Even considerably higher starting currents are briefly permissible at the outputs, so that a trouble-free start-up of the connected devices is guaranteed. Wiring in the field using the power distributor box is significantly simpler and less expensive than equipping the system with additional terminal boxes with fuses.
The diagnostic and control functions of the EP9214 provide additional benefits. Apart from monitoring the input current, the currents in the control channel and the peripheral voltage channel are also monitored separately. In addition, the monitoring, limitation and, if necessary, the switching off of the power supply is possible for both channels. The EP9214 power box can be fully controlled via the EtherCAT network and the current diagnostics can be carried out conveniently via the controller. The eight 24 VDC voltage circuits can also be separately switched on or off directly via EtherCAT in order to increase the energy efficiency of the plant.
Suppression and safety solutions for fire and gas in mission-critical industries
Fieldbus & Industrial Networking
By representing world-leading brands and focusing on fully integrated, certified systems, HMA South Africa is positioning itself as a trusted partner in fire detection, suppression and explosion-proof safety solutions across the continent.
Read more...Integrating fire alarm systems into building management systems Beckhoff Automation
Fieldbus & Industrial Networking
Fire alarm systems work independently of the building automation system. Schrack Seconet has developed a flexible gateway using ultra-compact industrial PCs and TwinCAT from Beckhoff, which can be used to flexibly convert a customer-specific communication protocol to a wide range of transmission standards.
Read more...Fire and gas suppression solutions for mission-critical industries
Fieldbus & Industrial Networking
By representing world-leading brands and focusing on fully integrated, certified systems, HMA South Africa is positioning itself as a trusted partner in fire detection, suppression and explosion-proof safety solutions across the continent.
Read more...The future of manufacturing
Fieldbus & Industrial Networking
Industrial automation is evolving at an unprecedented pace. At the forefront of this transformation is the Siemens SIMATIC ET 200SP HA Distributed I/O system. This is a flexible and scalable distributed I/O system for modern signal transfer from the field to the control level.
Read more...Time-sensitive networking RJ Connect
Editor's Choice Fieldbus & Industrial Networking
In this article, we will explore what is driving the rise of time-sensitive networking, how it is reshaping industrial efficiency, the challenges when deploying this technology, and ways to tackle these challenges.
Read more...Loop Signature 30: Nonlinearity in control loops (Part 1) Michael Brown Control Engineering
Editor's Choice Fieldbus & Industrial Networking
If nonlinearity occurs it means that if one is to carry on controlling with the same response to changes in load or setpoint, then the tuning of the controller will also need to be adjusted to meet the new conditions.
Read more...PC-based control regulates innovative dehumidifiers Beckhoff Automation
Fieldbus & Industrial Networking
Swedish company, Airwatergreen is breaking new ground in the dehumidification of air in industrial buildings and warehouses. The patented CVP technology reduces energy requirements and ensures an indoor climate that prevents corrosion and mould growth. PC-based control from Beckhoff regulates this innovative process.
While every effort has been made to ensure the accuracy of the information contained herein, the publisher and its agents cannot be held responsible for any errors contained, or any loss incurred as a result. Articles published do not necessarily reflect the views of the publishers. The editor reserves the right to alter or cut copy. Articles submitted are deemed to have been cleared for publication. Advertisements and company contact details are published as provided by the advertiser. Technews Publishing (Pty) Ltd cannot be held responsible for the accuracy or veracity of supplied material.