Electrical Power & Protection


Automatic power factor correction systems from AC/DC Dynamics

April 2013 Electrical Power & Protection

With the growing demand in the area of energy management and monitoring, the VMP and VMPC PFC ranges from AC/DC Dynamics feature 3 phase monitoring and both single and 3 phase compensation. This gives users the ability to determine precise compensation. On the technical side, 3 C/Ts are required to be installed with this monitoring system for accurate compensation and measurement. The VMPC range is supplied standard with a GEM-10, Ethernet, Modbus and GPRS gateway to address any communication interface requirements.

The Entes RGS-12 controller measures active energy (kWh), reactive energy (kVArh) and has energy ratio alarms. It measures and displays THDI, THDV (total harmonic distortion) for current and voltage with adjustable THDV alarm levels. Despite all the extra functions the controller is easy to set up, requiring no extra programming in auto setup mode.

The company has also launched a Web page where all parameters, measurements and alarms are recorded and monitored. The new software can be custom made to suite personal requirements. Monthly utility consumption, bills and various other power quality reports can be generated with ease, assisting management of the incoming supply quality, consumption and PFC unit.

The cabinet design provides top and bottom cable entry for easy installation and modularity allows for quick and easy configuration. If extra compensation is required, the system allows for extra racks or higher kVAr racks to be installed. The unique modular cabinets can be bolted up against each other in the event that the load demand increases. All that’s required is interconnection and adjustments to the controller’s set points. The design further incorporates MCC rack design, which utilises superior plug-in connectors.

The adjustable temperature controlled cooling fan’s location and ventilation design, extracts the air across the capacitors and contactors thus assisting with the heat transfer out of the cabinet.





Share this article:
Share via emailShare via LinkedInPrint this page

Further reading:

Retrofitting for sustainability
Schneider Electric South Africa Electrical Power & Protection
As budgets tighten and sustainability targets increase, retrofit and modernisation strategies are gaining traction across Africa, allowing organisations to upgrade only what limits performance while preserving existing infrastructure and extending asset life.

Read more...
USB-Datalogger for voltage 0 to 30 V DC
Vepac Electronics Electrical Power & Protection
The PeakTech 5186 is a data logger for DC voltages from 0 V to 30 V with terminals on the top of the device.

Read more...
Pole-top boxes for smarter, more secure electricity networks
Electrical Power & Protection
As South Africa accelerates the rollout of smart prepaid electricity metering, innovative enclosure technology from Power Process Systems is helping utilities improve network security, reduce electricity theft and protect critical electrical infrastructure.

Read more...
Simplifying electrical design compliance
Electrical Power & Protection
Referro Systems highlights how Rockwell Automation’s Global SCCR Tool simplifies short-circuit current rating compliance for complex industrial electrical systems.

Read more...
Engineering resilience into Africa’s energy future
Electrical Power & Protection
Zutari’s managing director of water explains how Burundi’s landmark Jiji and Mulembwe hydropower projects demonstrate what resilient, climate-adapted infrastructure delivery looks like – and what this means for Africa’s energy future.

Read more...
Voltage Tester with LED-Display
Vepac Electronics Electrical Power & Protection
The PeakTech 1094 is a reliable and robust two-pole voltage tester that has been specially developed for the safe and precise measurement of AC and DC voltages in the 12 to 400 V range.

Read more...
Schneider Electric launches circuit breaker for cost-effective LV protection
Schneider Electric South Africa Electrical Power & Protection
Schneider Electric has launched its EasyPact CVS C4 moulded case circuit breaker in South Africa, extending the Easy series to 1 600 A and giving consultants, contractors, and end users a cost-effective solution for non-critical low-voltage applications.

Read more...
Schneider Electric launches cost-effective, high-performance LV protection
Schneider Electric South Africa Electrical Power & Protection
Schneider Electric has launched its EasyPact NW air circuit breaker in South Africa, extending its Easy series portfolio with a cost-effective solution for non-critical low-voltage applications in commercial, industrial and residential projects.

Read more...
SF6-free switchgear brings digital intelligence to mining
Schneider Electric South Africa Electrical Power & Protection
Combining pure-air switchgear with embedded digital intelligence helps mines cut greenhouse gas emissions, improve safety and meet sustainability targets while enabling real-time visibility into critical electrical assets.

Read more...
Turning plastic waste into clean hydrogen
Electrical Power & Protection
Researchers have developed a solar-powered process that converts plastic waste into hydrogen and useful industrial chemicals while using spent acid from vehicle batteries. The approach could help create a circular system for dealing with several challenging waste streams at the same time.

Read more...









While every effort has been made to ensure the accuracy of the information contained herein, the publisher and its agents cannot be held responsible for any errors contained, or any loss incurred as a result. Articles published do not necessarily reflect the views of the publishers. The editor reserves the right to alter or cut copy. Articles submitted are deemed to have been cleared for publication. Advertisements and company contact details are published as provided by the advertiser. Technews Publishing (Pty) Ltd cannot be held responsible for the accuracy or veracity of supplied material.