July 2026Maintenance, Test & Measurement, Calibration
To help preserve one of France’s protected historic landmarks, Omniflex was selected by civil engineering company Freyssinet to deliver its PowerView 18-zone impressed current cathodic protection system for the Perret Tower in Grenoble. Opened in 1925, the observation tower in the Paul Mistral public park was the first reinforced concrete tower built in Europe, and was designated a French national heritage site in 1998. The project demonstrates how modern corrosion-protection technology can be applied sensitively to reinforced concrete heritage structures.
As a historic reinforced concrete structure, the tower required a corrosion protection solution capable of preserving the site while respecting its heritage significance. The tower’s height and exposed location also increase the risk of lightning strikes, creating additional challenges for monitoring and control equipment. Access to heritage structures is often restricted and physical intervention must be minimised, so any corrosion protection system needed to deliver long-term reliability with as little onsite disruption as possible. To address these requirements, Omniflex delivered a remotely monitored solution incorporating integrated surge protection and real-time system oversight.
“The PowerView system was designed to provide operators with continuous visibility of corrosion protection performance while reducing the need for costly and laborious site visits,” says Stuart McIntosh, business manager at Omniflex. “For the Perret Tower project, it was important to combine long-term corrosion protection with robust remote monitoring and surge protection capabilities to help preserve the historic landmark’s structure for future generations.”
The system was supplied in four IP66 GRP enclosures and incorporates Omniflex’s PowerView remote monitoring technology, enabling engineers to securely access system data and control functionality remotely from anywhere with an internet connection, 24/7. This approach helps reduce disruption to the site and ensures issues can be identified and addressed quickly. Integrated surge protection devices also help safeguard sensitive electrical and electronic equipment against lightning-related damage.
Designed to monitor 18 protection zones and 152 inputs, the PowerView system provides operators with secure access to real-time performance data and remote control capabilities via a web-based interface. By combining continuous corrosion protection with 24/7 monitoring, the solution helps safeguard one of Grenoble’s most significant historic landmarks.
Infrared thermometers for electrical, industrial and HVAC applications Comtest
Maintenance, Test & Measurement, Calibration
: Comtest, distributor of Fluke test and measurement equipment, explains how handheld infrared thermometers are transforming maintenance in electrical, industrial and HVAC environments, with three measurement strategies and a wide range of practical applications.
Read more...Reverse-engineering legacy industrial gearbox parts
Maintenance, Test & Measurement, Calibration
WEG Africa’s turbine workshop uses 3D scanning technology to reverse-engineer components for legacy gearboxes, turbines and compressors, enabling equipment to run for decades after OEM support and spare parts have dried up.
Read more...Unlocking ICCP remote monitoring Omniflex Remote Monitoring Specialists
Maintenance, Test & Measurement, Calibration
Cathodic protection keeps buried and submerged pipelines safe from corrosion, but verifying it traditionally means costly, hazardous manual site visits. Omniflex explains how a retrofit module brings remote monitoring to ageing transformer rectifiers without replacing functional infrastructure.
Read more...Microdieseling – the explosions you never hear
Maintenance, Test & Measurement, Calibration
Microdieseling is a pressure-induced thermal degradation mechanism in which entrained air bubbles are compressed so rapidly that the surrounding oil ignites, producing soot, varnish and sludge. WearCheck explains how it happens, why the damage varies, and how oil analysis detects it.
Read more...Electrostatic spark discharge – when static strikes back Wearcheck
Maintenance, Test & Measurement, Calibration
WearCheck technical manager, Steven Lumley explains how static electricity accumulates in modern low-conductivity lubricants, why compact system designs and fine filtration make ESD more likely, and how to recognise the degradation it leaves behind.
Read more...High-speed cameras for crash testing Horne Technologies
Maintenance, Test & Measurement, Calibration
Vision Research has expanded its Phantom C-series with two cameras optimised for crash and safety testing, offering 4 and 8 megapixel sensors rated to 170G, up to 1180 frames per second, and Phantom Academy application training planned for South Africa next year.
Read more...Mine-wide water monitoring at Nkomati Nickel plant Omniflex Remote Monitoring Specialists
Data Acquisition & Telemetry
Omniflex is supplying a new wireless telemetry system for Nkomati Nickel plant, restoring mine-wide monitoring of water and pumping systems across six outstations as the operation prepares to resume following a R753 million restart investment.
Read more...SKF extends remanufacturing expertise to bearing clearance modification SKF South Africa
Maintenance, Test & Measurement, Calibration
Using its clearance modification expertise, SKF helped a mining equipment OEM salvage spherical roller bearing inventory that would otherwise have been scrapped, confirming a new capability within its remanufacturing services and avoiding redundant procurement.
Read more...When maintenance-system compliance starts replacing plant reliability Wearcheck
Maintenance, Test & Measurement, Calibration
WearCheck ARC division manager, Annemie Willer argues that the greatest threat to effective maintenance is no longer a lack of technology, but the gradual replacement of technical judgement by CMMS compliance, leaving no one owning the machine.
While every effort has been made to ensure the accuracy of the information contained herein, the publisher and its agents cannot be held responsible for any errors contained, or any loss incurred as a result. Articles published do not necessarily reflect the views of the publishers. The editor reserves the right to alter or cut copy. Articles submitted are deemed to have been cleared for publication. Advertisements and company contact details are published as provided by the advertiser. Technews Publishing (Pty) Ltd cannot be held responsible for the accuracy or veracity of supplied material.