Designing the modern AI cooling stack

October 2026 Industrial Computer Hardware


Canninah Dladla, cluster president for sub-Saharan Africa at Schneider Electric.

In the largest year-over-year jump in AFCOM’s decade of research, the group’s State of the Data Centre Report 2026 found that average rack density has climbed from 16 to 27 kW in just one year. The study also found that 72% of operators expect AI workloads to increase data centre capacity requirements, while more than 60% of organisations are either already using liquid cooling or plan to adopt it within the next two years.

Scaling direct-to-chip liquid cooling demands a complete rethink of the cooling stack, with the industry challenged to design integrated, scalable architectures that support next-generation high-density compute.

Six paths to heat rejection

To select the most appropriate liquid cooling architecture, data centre operators must weigh four factors: compatibility with existing cooling infrastructure, deployment size, speed of deployment, and energy efficiency. Three heat rejection methods combined with one of two coolant distribution unit (CDU) form factors create the six most common liquid cooling architectures.

The first step is to identify the heat rejection method which determines how heat is transferred outdoors, and dictates the type of heat exchange used by the system.

Reject to Air: Liquid to air, existing system. The CDU expels heat into data centre air, working with existing air-cooled infrastructure. This is best for small deployments from a single server to a few racks where speed of deployment is the priority.

Reject to Facility Water: Liquid to liquid, existing system. The CDU connects to chilled or condenser water loops. This is suited to mid- to large-scale sites with chiller plants, prioritising efficiency over rapid rollout.

Reject to Independent Water: Lliquid to liquid, dedicated system. This builds a new heat rejection system for liquid cooling. It is ideal for major deployments focused on efficiency and heat reuse, where longer timelines and new piping are feasible.

The CDU form factor determines how cooling fluid is distributed among IT equipment. A rack-mounted CDU is installed in the rack, creating an isolated loop. Best for one to ten racks needing rapid installation, it limits failures to one rack, but becomes less efficient and costlier per kW as scale grows.

A floor-mounted CDU is placed on the facility floor, serving multiple racks or rows via a shared loop. Suited for more than ten racks where workloads can tolerate a common-cause failure, it offers better efficiency, saves rack space and lowers cost per kW at scale, though a single failure affects all connected racks.

Retrofitting existing facilities

Integrating high-density AI clusters into existing brownfield facilities presents specific engineering constraints. Most legacy halls were designed for power densities and cooling methodologies that are fundamentally challenged by modern AI accelerators. Successful retrofits depend on localised heat rejection strategies that minimise disruption to the central plant.

Rear-door heat exchangers stabilise rack temperatures, even under peak AI workloads, making them a practical server cooling option for GPUs. Where water access is limited, heat dissipation units can remove heat from AI servers and reinject it directly into the room air, eliminating the need to route facility water to the rack. Direct-to-chip liquid cooling at the rack level also allows for staged upgrades, preventing major central plant overhauls and making modernisation of smaller, constrained sites more feasible.

The logic of efficiency: the 7+3 framework

Sustainability in the AI era is governed by the trade-offs between energy and water consumption. Optimising power usage effectiveness requires a sophisticated understanding of approach temperatures, the temperature difference between the primary and secondary cooling loops. The sustainability and efficiency of a direct-to-chip liquid cooling system are driven by a holistic view of the architecture, from the chip to the chiller.

Seven core design factors determine energy and water consumption:

• Outdoor heat rejection: Air-cooled chillers with economisers save water compared with cooling towers, which consume heavily year-round.

• IT inlet fluid temperatures: Raising supply temperatures, for example, from 25 to 45°C, cuts compressor energy by 30 to 40% and water use by 40 to 60%.

• Rack power density: Higher AI-driven densities boost liquid heat capture, slightly improving plant efficiency.

• CDU type: Liquid-to-liquid CDUs are more efficient than liquid-to-air units, avoiding extra heat exchange cycles.

• Component selection: Efficient pumps and heat exchangers with low approach temperatures enable higher facility water temperatures, more economiser hours and less compressor energy.

• Coolant type: Propylene glycol at 25% concentration is standard for reliability. While deionised water offers better thermal capacity, it requires more complex chemical management.

• Heat reuse: Higher liquid cooling temperatures enable waste heat recovery for district heating or industrial use, improving the energy reuse factor.

Three operational practices complete the framework:

• Control scheme: Advanced systems use digital twins and dynamic pump control to match real-time loads, avoiding wasted energy.

• Maintenance: Regular coolant monitoring and filter cleaning prevent damage and reduce pump strain.

• Adaptive deployment: Modular, phased builds align infrastructure with evolving IT demand, avoiding stranded capacity and excess carbon.

Designing for AI requires mastering fluid dynamics and material science at scale. A physics-based architectural strategy, rather than an anecdotal rule of thumb, allows facility engineers to deploy direct-to-chip cooling with confidence.


Credit(s)



Share this article:
Share via emailShare via LinkedInPrint this page

Further reading:

Rugged, IP67-rated waterproof and dustproof embedded computers
Vepac Electronics Industrial Computer Hardware
The QBiX-WP embedded system range from Vepac Electronics is built inside a sealed aluminium chassis with M12 connectors, operating in extreme temperatures and withstanding heavy dust or liquid immersion for harsh factory floors and outdoor installations.

Read more...
How modular edge data centres are powering Africa’s digital leap
Industrial Computer Hardware
As Africa’s digital economy stretches far beyond its metros, compact, fast-to-deploy modular edge data centres are emerging as the practical way to bring compute power close to remote and underserved regions where demand is rising fastest.

Read more...
Software-defined automation is overcoming hardware interoperability limits
Schneider Electric South Africa SCADA/HMI
Schneider Electric’s Kobus Vermeulen and Sydney Higgo explain how open communication standards and software-defined architectures are enabling industrial operators to integrate legacy equipment, new control systems, and cloud platforms without disrupting operations.

Read more...
Powerful industrial motherboard
Vepac Electronics Industrial Computer Hardware
AAEON’s MIX-PTLWV1 Mini-ITX motherboard introduces Intel Core Ultra series 3 processing, offering greater memory capacity, faster networking and a wide power input range for high-performance industrial AI at the edge.

Read more...
Calcamite partners with Schneider Electric and 4Sight for smart water management
Schneider Electric South Africa Editor's Choice
Schneider Electric, AVEVA and 4Sight OT Automation are helping South African wastewater specialist, Calcamite, digitalise its modular treatment plants through a scalable edge-to-cloud automation platform, with the award-winning Gourikwa pilot now scaling to hundreds of remote sites.

Read more...
AI in industry is an early warning system, not a guarantee
Schneider Electric South Africa IT in Manufacturing
Schneider Electric’s Paul Steyn argues that AI in industrial maintenance is only as good as the infrastructure and people behind it, and explains the three layers a facility needs before predictive maintenance can deliver on its promise.

Read more...
Schneider Electric concludes Innovation Summit Middle East and Africa
Schneider Electric South Africa News
Schneider Electric's Innovation Summit Middle East and Africa, held in Abu Dhabi with more than 2500 attendees, explored the convergence of energy, AI and industrial software, launched an Industrial AI study and announced the NEST Accelerator Programme for energy and industrial tech startups.

Read more...
The grid needs to become more intelligent
Schneider Electric South Africa Electrical Power & Protection
South Africa’s power grid is becoming bidirectional and far more dynamic as distributed energy resources proliferate. Schneider Electric’s Nishandra Bajinath explains why digitalisation, DERMS and aggregation are essential to keep this increasingly complex grid stable and efficient.

Read more...
Schneider Electric concludes Innovation Summit Middle East and Africa
Schneider Electric South Africa News
Schneider Electric’s Innovation Summit Middle East and Africa, held in Abu Dhabi with more than 2500 attendees, explored the convergence of energy, AI and industrial software, launched an Industrial AI study and announced the NEST Accelerator Programme.

Read more...
The next generation of engineers is building living labs of innovation
Schneider Electric South Africa IT in Manufacturing
Graduate engineers at Schneider Electric East Africa designed, integrated and commissioned the smart building systems in the company’s new Nairobi head office, demonstrating how practical, real-world project experience accelerates engineering capability and confidence.

Read more...









While every effort has been made to ensure the accuracy of the information contained herein, the publisher and its agents cannot be held responsible for any errors contained, or any loss incurred as a result. Articles published do not necessarily reflect the views of the publishers. The editor reserves the right to alter or cut copy. Articles submitted are deemed to have been cleared for publication. Advertisements and company contact details are published as provided by the advertiser. Technews Publishing (Pty) Ltd cannot be held responsible for the accuracy or veracity of supplied material.




© Technews Publishing (Pty) Ltd | All Rights Reserved