Flow Measurement & Control


Volume flow measuring system features inertia-free alarm indication

June 2000 Flow Measurement & Control

Durag's new D-FL-100 measuring system continuously determines the flow velocity and the flowrate of the exhaust gas. Alarm levels are preselectable and any alarms will be indicated inertia-free, permitting necessary interventions in the plant control system so as to comply with prescribed emission limit values.

Operating on the principle of differential pressure, the D-FL 100 units are available in two types. The D-FL 100-I is designed for flow measuring without temperature and pressure compensation and the D-FL 100-II for flow measuring with temperature and pressure compensation.

The probe has two separate chambers, between which a pressure difference, caused by the flow in the duct, builds up. The differential pressure at the probe is proportional to the square of the gas speed.

The volume flow can be converted from operational to standard conditions by the D-FL 100-10 microprocessor evaluation unit. For this purpose, two additional current inputs (0-20 mA) for a temperature probe and a pressure probe have been provided at the evaluation unit. If an emission evaluation computer is available, the evaluation unit is not required.

Special designs are available for use in aggressive exhaust gases. A hastelloy flow probe is recommended for heating power plants, chemical plants and in paper manufacturing. For operating temperatures of over 600°C, an inconel flow probe is available.

The lengths of measuring ranges offered are 400-2000 mm, 2000-4000 mm or 4000 mm. Exhaust gas temperature over the exhaust gas dew point is up to +320°C. An automatic backflow purging feature is available as an option.





Share this article:
Share via emailShare via LinkedInPrint this page

Further reading:

Uncompromising flow rate measurement
Burkert South Africa Flow Measurement & Control
Bürkert’s FLOWave is a hygienic and safe flow measurement solution with many benefits for pharmaceutical or food production processes.

Read more...
Electromagnetic flow measurement
Siemens South Africa Flow Measurement & Control
The SITRANS FM electromagnetic flowmeters from Siemens deliver high-precision volume measurement of electrically conductive liquid applications – from water, wastewater and irrigation to hygienic processes and even mining slurries with magnetic particles.

Read more...
ABB unveils next generation of electromagnetic flowmeters
ABB South Africa Flow Measurement & Control
ABB has launched its latest generation of electromagnetic flowmeters, bringing unmatched accuracy, connectivity and flexibility to industrial and utility applications.

Read more...
Precision measurement for ultra-pure water systems
Flow Measurement & Control
[Sponsored] Ultra-pure water (UPW) is essential in industries where even minor contaminants can impact product quality and process integrity. Anton Paar’s L-Cor Coriolis mass flowmeters provide a highly accurate and hygienic solution by directly measuring the mass of the liquid using the Coriolis effect, ensuring a high level of cleanliness.

Read more...
Inline process solutions for gold mining
Anton Paar Flow Measurement & Control
[Sponsored]The extraction and processing of gold ore requires precision and efficiency to maximise yield and minimise losses. Automation and continuous monitoring of critical process steps are essential to ensure optimal production. Anton Paar offers advanced inline measurement solutions which enable full automation and real-time monitoring of key steps in gold extraction and processing.

Read more...
Magnetic-inductive flow sensor
ifm - South Africa Flow Measurement & Control
The SMF magnetic-inductive flow sensor revolutionises liquid and creamy flow measurement. With IO-Link, it enables digital data transmission, eliminating blind spots in production.

Read more...
Hygienic flow measurement for the food industry
ifm - South Africa Flow Measurement & Control
With the SMF magnetic-inductive flow meter, ifm offers a solution for the hygienic flow measurement of media with variable flow rates through a pipe, such as beer, milk or fruit juice.

Read more...
Case History 197: Bad reboiler temperature control.
Michael Brown Control Engineering Editor's Choice Flow Measurement & Control
It is very important that reboiler temperature controls operate well in petrochemical refineries, or the product quality can really suffer. I was asked to check such a control in a refinery where they were having problems with one of these controls.

Read more...
Precision measurement for ultra-pure water systems
Anton Paar Flow Measurement & Control
[Sponsored] Ultra-pure water (UPW) is essential in industries where even minor contaminants can impact product quality and process integrity. Anton Paar’s L-Cor Coriolis mass flowmeters provide a highly accurate and hygienic solution by directly measuring the mass of the liquid using the Coriolis effect, ensuring a high level of cleanliness.

Read more...
Eliminating splashbacks, spills and early shutoffs in ultra high-flow fuelling
Flow Measurement & Control
Husky Corporation has unveiled the latest innovation in fuelling technology with its newly designed StreamShaper for ultra high-flow applications, which minimises early shutoffs and splashback spills.

Read more...