Maintenance, Test & Measurement, Calibration


Valve, actuator, sensors and diagnostics module in one package

July 2002 Maintenance, Test & Measurement, Calibration

Integrated sub-systems have enabled Festo to meet the growing need for 'full functionality with minimised costs for purchasing, installation and maintenance' with its DNCV standard cylinder/valve combination.

As per DIN ISO 6431, the drive, valve, sensors and flow-control valve are all integrated, as are the communications interfaces and a diagnostics module. The DNCV standard cylinder/valve combination is equipped to meet the needs of a broad spectrum of users - and can be employed flexibly in distributed applications such as automobile production, special machine construction, conveyor, production and packaging technology, as well as in building and air-conditioning systems.

The DNCV is a complete package, due to the many possible variants and additional functions provided as standard. Among the further technical features of the device are a manual override, ducted exhaust air, internal air supply and a diagnostics module.

The standard multipin connection and PLC, ASI-EVA or CPX interfaces for use with various bus protocols mean that the DNCV is open to all types of controls and systems. Its diagnostics module is equipped with limit-switch monitoring as standard, providing feedback on the operational status. Optionally, the diagnostics module can be used to monitor cylinder speed or the number of operating cycles to facilitate preventive maintenance. Settings are made quickly and simply using DIP switches, which means that no additional PLC programming is required.

The integration of various functions and by positioning the manual override on the drive, electrical and pneumatic connection is greatly simplified. This means that the installation of the cylinder and the release of the valve can now be done by one person. Mounting materials from the modular DNC system make commissioning even simpler.

For more information contact: Richard Teagle, MD, Festo, tel: 011 971 5500, e-mail: [email protected], website: www.festo.com



Credit(s)



Share this article:
Share via emailShare via LinkedInPrint this page

Further reading:

Oils don’t die, they degrade
Wearcheck Maintenance, Test & Measurement, Calibration
WearCheck explores the main ways lubricants degrade in service and how these degradation modes affect oil performance and machine reliability.

Read more...
Real-time spectrum analyser
Vepac Electronics Maintenance, Test & Measurement, Calibration
The PXE series real-time spectrum analyser covers frequencies up to 20 GHz with a 100 MHz analytical bandwidth and ultra-fast sweep speed, supporting spectrum monitoring, interference finding and RF test and measurement functions.

Read more...
Preserving a French heritage landmark
Omniflex Remote Monitoring Specialists Maintenance, Test & Measurement, Calibration
Omniflex supplied a remotely monitored impressed current cathodic protection system for the Perret Tower in Grenoble, a protected French heritage site, combining 24/7 corrosion protection with integrated surge protection against lightning strikes.

Read more...
Operational efficiencies and safety compliance with preventive maintenance programmes
Maintenance, Test & Measurement, Calibration
Konecranes explains how its Lifecycle Care Preventive Maintenance programme reduces unexpected downtime, improves safety compliance and delivers measurable financial benefits for operators of cranes and lifting equipment across any make or sector.

Read more...
Portable appliance tester
Vepac Electronics Maintenance, Test & Measurement, Calibration
Vepac Electronics’ new portable appliance tester enables precise safety testing of electrical appliances in accordance with DGUV regulation 3 and BetrSichV, with simple three-button operation and battery-powered mobility.

Read more...
Why lubrication fails in mining and what to do about it
Maintenance, Test & Measurement, Calibration
Lubrication Engineers explains the recurring failure points behind mining lubrication problems and how the right product, storage and application practices can improve equipment reliability.

Read more...
When digital twins move from concept to critical tool
IT in Manufacturing System Integration & Control Systems Design Maintenance, Test & Measurement, Calibration
Digital twins are moving out of the lab and onto the mine, the factory floor and the transport network where they predict failures before they happen. Amritesh Anand looks at where they earn their keep, the data and integration work behind them, and the security questions every organisation should ask before switching one on.

Read more...
Why asset level intelligence is now essential for resilient wastewater plants
Schneider Electric South Africa Maintenance, Test & Measurement, Calibration
Sub-Saharan Africa’s wastewater operators face mounting pressure to keep ageing plants running smoothly and meet tougher environmental standards, all while lacking visibility into the health of their medium-voltage (MV) drives and other critical rotating assets. Adding predictive analytics, digital twins and enterprise dashboards enables optimisation across multiple sites, ensuring every drop moves safely and efficiently through the water cycle.

Read more...
Engineering simplicity: shaping the future of valve automation
Festo South Africa Editor's Choice Valves, Actuators & Pump Control
Festo’s VTOP pneumatic assembly offers a streamlined approach to managing pneumatic and electrical interfaces at the valve assembly.

Read more...
How multiple boilers can minimise costly downtime
Maintenance, Test & Measurement, Calibration
Associated Energy Services explains how multi-boiler systems reduce downtime risk for South African manufacturers, covering redundancy planning, fuel source diversification and the strategic management of backup boiler capacity.

Read more...









While every effort has been made to ensure the accuracy of the information contained herein, the publisher and its agents cannot be held responsible for any errors contained, or any loss incurred as a result. Articles published do not necessarily reflect the views of the publishers. The editor reserves the right to alter or cut copy. Articles submitted are deemed to have been cleared for publication. Advertisements and company contact details are published as provided by the advertiser. Technews Publishing (Pty) Ltd cannot be held responsible for the accuracy or veracity of supplied material.