Flow Measurement & Control


Clamp-on ultrasonic flow measurement

September 2018 Flow Measurement & Control

Kobold’s portable DUC-MP and the stationary DUC-MF are designed for continuous non-intrusive flow measurement where accurate and drift-free operation is required for liquids in filled pipes. The devices are hygienic, leak proof and monitor all aggressive and toxic liquids without a problem. A special advantage is that the ultrasonic sensors are clamped onto the outside of the pipe, so cutting the pipe is not necessary for installation. Similarly, there is no requirement for process shutdown, significantly reducing the operating costs.

The robust Quickfix mounting kit enables precise and quick sensor installation. With the Quick Setup option, the transmitter can be configured in less than one minute, and in less than two minutes, the sensors are mounted onto the pipe.

By default, the transmitter operates at medium temperatures from -40 to 150°C and flow rates of up to 30 m/second in pipe sizes from DN10 to DN6000. DUC works on the high-precision ultrasonic transit time method. The AND-Technology (anti-noise deflector), results in the ultrasonic waves being guided and coupled in such a way that unwanted echoes and signal variations are avoided. The flow rate is measured periodically, typically 50-150 times per second. Because of the latest digital signal processing, DUC operates reliably even under influence of EMC radiations or unwanted machine noises.

Accurate measurements are possible even where conventional devices fail, for example in unfavourable conditions, such as high particle and gas pollution situations. The clear menu-structure, easy operation via eight buttons and the large graphics-capable text display facilitate measurement. Battery operation and the 4 GB memory card make the portable version of DUC ideal for temporary measuring tasks. Application areas include power plants, water and wastewater, oil and gas, and food and beverage production.

For more information contact Instrotech, +27 10 595 1831, [email protected], www.instrotech.co.za



Credit(s)



Share this article:
Share via emailShare via LinkedInPrint this page

Further reading:

Hygienic ultrasonic flow sensor
ifm - South Africa Flow Measurement & Control
The SU Puresonic Hygienic ultrasonic sensor from ifm detects flows of conductive and non-conductive media with high precision.

Read more...
VEGA pressure instrumentation supports resilient water network management
VEGA Controls SA Pressure Measurement & Control Flow Measurement & Control
As rapid urbanisation and climate pressures strain water networks across Africa, accurate real-time pressure monitoring has become a strategic necessity. VEGA’s pressure instrumentation helps utilities reduce losses, protect infrastructure and meet sustainability targets.

Read more...
Field calibration made easy
Instrotech Maintenance, Test & Measurement, Calibration
Instrotech’s locally designed and manufactured Calog calibrator range feature a rugged IP54-rated housing, backlit display with data logging via SD card, and a lithium-ion battery with approximately eight hours of run time.

Read more...
Groundwater level measurement using LoRa module
Instrotech Level Measurement & Control
Monitoring groundwater levels across large industrial sites is critical. Salzgitter Digital Solution was tasked with developing a fully automated and digital monitoring system using Long Range Wide Area Network technology.

Read more...
Reducing fluid control and automation complexity in pharma process development
Flow Measurement & Control
Designing and building pharmaceutical processes or skids demands close coordination between mechanical, electrical, instrumentation and automation engineering teams.

Read more...
Flow imaging microscopy for the early detection of harmful algal blooms
Yokogawa South Africa Flow Measurement & Control
Yokogawa’s advanced flow imaging microscopy technology, FlowCam is helping utilities move from reactive treatment to proactive prevention of harmful algal blooms in reservoirs, dams and freshwater sources.

Read more...
Never waste a drop
Flow Measurement & Control
Manufacturers of pumps, valves and related equipment have an important role to play when systems for water are being designed or upgraded and should be included at every stage of a project to ensure that the work is carried out within the equipment’s capabilities.

Read more...
Infrared solutions for glass manufacturing challenges
Instrotech Temperature Measurement
In the glass industry, infrared temperature monitoring is crucial for maintaining product quality and process efficiency. Instrotech has infrared sensors and cameras which provide non-contact temperature measurements, making them ideal for these high-temperature environments.

Read more...
Ultrasonic flow meters
ifm - South Africa Flow Measurement & Control
The ultrasonic flow meter of the SU series from ifm - South Africa monitors liquid media such as water, glycol solutions or industrial oils. It detects the three process categories volumetric flow quantity, consumed quantity and medium temperature.

Read more...
How utilities identify water losses in Northern Europe
Flow Measurement & Control
Norwegian leak detection specialist, Ovarro outlines how municipalities are responding to hidden water loss using acoustic monitoring and analysis tools that provide early indications of developing leaks.

Read more...









While every effort has been made to ensure the accuracy of the information contained herein, the publisher and its agents cannot be held responsible for any errors contained, or any loss incurred as a result. Articles published do not necessarily reflect the views of the publishers. The editor reserves the right to alter or cut copy. Articles submitted are deemed to have been cleared for publication. Advertisements and company contact details are published as provided by the advertiser. Technews Publishing (Pty) Ltd cannot be held responsible for the accuracy or veracity of supplied material.




© Technews Publishing (Pty) Ltd | All Rights Reserved