Fluke has on offer two three-phase power loggers, the 1736 and 1738, giving users the data needed to make critical power quality and energy decisions in real time. They are specifically engineered to conduct energy studies and basic power quality logging, automatically capturing and logging over 500 power quality parameters for more insight into the data needed to optimise system reliability and savings.

The 1736 and 1738 are the first three-phase power loggers built with the Fluke Connect mobile app and software, enabling users to measure, capture and log all relevant characteristics of electric power and enabling management and analysis of large data sets.

They provide:

• More visibility: They automatically capture and log over 500 power quality parameters.

• Reduced uncertainty: Visibility through Fluke Connect enables users to view collected data to ensure the data being collected is correct, either at the panel or remotely. By powering the logger directly from the measured line and the intelligent verification function that digitally corrects common connection issues, measurement system errors are significantly reduced.

• Better decision-making capabilities: Data can be accessed and shared remotely via the Fluke Connect app to maintain safer working distances and make critical decisions in real-time, reducing the need for protective equipment, site visits and check-ins. Chart and graph measurements allow the user to create detailed reports with Fluke Energy Analyse Plus software.

The Fluke 1736 and 1738 have more power quality measurement capability than their predecessor, the Fluke 1730, a pure energy logger. This functionality is a subset of the Fluke 1736/1738. For users performing both basic power quality studies and energy studies, the 1736/1738 enables users to measure, capture and log all relevant characteristics of electric power and gives access to management and analysis of large data sets. The 1738 includes advanced limit based analysis (uses EN510160 limits), the capability to connect two Fluke Connect devices for logging of supplementary parameters and a Wi-Fi/Bluetooth (BLE) dongle.

The 1736 and 1738 feature:

• Key measurements: They simultaneously measure log voltage, current, power, harmonics and associated values as well as all three phases and neutral with four flexible current probes included.

• Connectivity on a portable power logger: Data can be viewed locally on the instrument via the Fluke Connect App or through the facility’s Wi-Fi infrastructure.

• Comprehensive logging: 20+ separate logging sessions can be stored on the instruments. All measured values are automatically logged for measurement trends.

• Capture of dips and swells: This includes event waveform snapshot, along with date, timestamp and severity to help pinpoint potential root causes of power quality issues.

• Complete in-the-field setup through the front panel or Fluke Connect app: There is no need to return to the workshop for download and setup or to take a computer to the electrical panel.

• Convenient instrument powering: The instrument is powered directly from the measured circuit, eliminating the need to find a power outlet while allowing the instrument to be secured safely inside electrical panels.

• Fully integrated logging: Other Fluke Connect devices can be connected to the 1738 to log up to two other parameters simultaneously, and virtually any parameter available on Fluke Connect enabled digital multimeters.

• Two USB ports: One port is for PC connection and the other for quick, simple data download to standard USB thumb drives or other USB devices for in-place, undisrupted logging.

• Compact size.

• Highest industry safety rating: 600 V CAT IV/1000 V CAT III.

• Security: They are safeguarded from theft with an optional hefty, durable Kensington lock.

• Power Quality Analyse application software: Every detail of energy consumption and power quality can be downloaded and analysed with automated reporting.

Accessories for the 1736, the hanger kit and magnetic voltage probes are must-haves, making installing much easier. Additionally, the upgrade kit for the 1736 allows users to fully upgrade their 1736 to a 1738 with all the functionality and accessories included with 1738. The auxiliary input cable is very useful if users wish to log other parameters like temperature along with energy and, especially if there are a wide variety of circuit types and sizes, additional current probes would be most useful. If users are planning to fully integrate their measurements, they can also buy FC3000 modules which can connect to the 1738 and log those measured values.

For more information contact Comtest, +27 (0)10 595 1821, [email protected], www.comtest.co.za



Credit(s)



Share this article:
Share via emailShare via LinkedInPrint this page

Further reading:

High performance power distribution
Electrical Power & Protection
Hexagon Electrical plays an important role in enhancing efficiency and safety through the supply and support of a wide range of critical equipment for hazardous industrial and mining sectors in Africa.

Read more...
Navigating solar energy adoption
Electrical Power & Protection
Although South Africa’s enhanced solar tax rebate has ended, solar and energy storage solutions remain accessible and achievable. By taking a proactive and strategic approach, businesses can successfully lower their operational costs, mitigate power outages, and secure long-term energy independence.

Read more...
As wind energy gains momentum, lack of grid infrastructure remains a bottleneck
Electrical Power & Protection
Interest in wind energy has gained significant momentum in South Africa, opening up new opportunities for investment. However, lack of grid infrastructure could prove to be a stumbling block in unlocking this potential.

Read more...
Portable appliance tester
Vepac Electronics Electrical Power & Protection
The new appliance tester from Vepac is the ideal tool for testing the safety of electrical appliances in accordance with DGUV regulation 3 and BetrSichV. It enables the precise measurement of protective conductor or touch current using the equivalent leakage current method.

Read more...
Is sustainability enough any more?
Electrical Power & Protection
With the planet’s resources stretched to the brink and no signs of improvement, it is time we look beyond sustainability and explore regenerative thinking and design.

Read more...
A simple guide to understanding the importance of IP ratings
Electrical Power & Protection
When selecting electrical products for industrial, commercial or even domestic use, it is crucial to consider how well they can withstand environmental factors like dust and water. This is where ingress protection (IP) ratings come into play.

Read more...
A milestone in electrical safety
ABB South Africa Electrical Power & Protection
Celebrating a milestone in electrical safety, ABB proudly marks the 100-year anniversary of its revolutionary Miniature Circuit Breaker.

Read more...
The power of water
Editor's Choice Electrical Power & Protection
The Alpenglow Hy4 is the world’s first water-based hydrogen combustion engine, offering a convincing alternative to traditional battery-electric vehicles and established hydrogen fuel cell designs.

Read more...
Optimising purification for green hydrogen production
Parker Hannifin - Sales Company South Africa Editor's Choice Electrical Power & Protection
Parker Hannifin delivers advanced purification and thermal management components that enhance green hydrogen production.

Read more...
A new chapter in geothermal engineering
Editor's Choice Electrical Power & Protection
The town of Geretsried in southern Germany has become a focal point in the global shift toward renewable energy. While the world’s attention often turns to wind turbines and solar panels, a quieter but no less powerful force is at work deep beneath the surface, geothermal energy.

Read more...









While every effort has been made to ensure the accuracy of the information contained herein, the publisher and its agents cannot be held responsible for any errors contained, or any loss incurred as a result. Articles published do not necessarily reflect the views of the publishers. The editor reserves the right to alter or cut copy. Articles submitted are deemed to have been cleared for publication. Advertisements and company contact details are published as provided by the advertiser. Technews Publishing (Pty) Ltd cannot be held responsible for the accuracy or veracity of supplied material.




© Technews Publishing (Pty) Ltd | All Rights Reserved