Maintenance, Test & Measurement, Calibration


Digital multimeter inside bus terminal I/O

December 2008 Maintenance, Test & Measurement, Calibration

With its new digital multimeter terminals, Beckhoff has added enhanced measurement technology functions to its leading edge I/O system. Using the digital multimeter with fieldbus interface for measuring current and voltage, measured values can be processed directly in the I/O system or by the master controller. These dynamic measuring terminals will be available for both the Beckhoff Bus Terminal system and for the EtherCAT Terminal system.

Utilising a powerful CPU, ultra fast communication (eg via EtherCAT), realtime software and an I/O interface to the outside world, Beckhoff PC-based control technology offers the ideal system for high-precision, high-speed measuring equipment. The use of the new Beckhoff KL3681 (Bus Terminal) and EL3681 (EtherCAT Terminal) significantly increases flexibility thanks to the wide input range and automated measuring range selection. High precision and simple, high-resistance measurement from 30 mV to 300 V allows the Bus Terminal to be used like a modernised digital multimeter.

In measuring applications in particular, the expected voltage is often not known during the planning phase. Automatic adjustment of the measurement range simplifies use and reduces stock levels. The digital multimeter terminals measure DC and AC voltages; in the case of AC voltage, the effective (RMS) value is determined.

Very good immunity to interference is achieved via the complete galvanic isolation of the electronic measuring system and a measurement interval of typically 200 ms. The measured result is equivalent to that of a good handheld multimeter, but the Bus Terminal also has an interface to all common fieldbuses via which it can be read out and parameterised.

Measurement ranges:

* Voltage: 30 mV to 300 V d.c., 100 mV to 300 V a.c..

* Current: 100 mA, 1 A, 10 A a.c./d.c.

* Resistance: 10 Ω to 10 MΩ.



Credit(s)



Share this article:
Share via emailShare via LinkedInPrint this page

Further reading:

Microdieseling – the explosions you never hear
Maintenance, Test & Measurement, Calibration
Microdieseling is a pressure-induced thermal degradation mechanism in which entrained air bubbles are compressed so rapidly that the surrounding oil ignites, producing soot, varnish and sludge. WearCheck explains how it happens, why the damage varies, and how oil analysis detects it.

Read more...
Electrostatic spark discharge – when static strikes back
Wearcheck Maintenance, Test & Measurement, Calibration
WearCheck technical manager, Steven Lumley explains how static electricity accumulates in modern low-conductivity lubricants, why compact system designs and fine filtration make ESD more likely, and how to recognise the degradation it leaves behind.

Read more...
High-speed cameras for crash testing
Horne Technologies Maintenance, Test & Measurement, Calibration
Vision Research has expanded its Phantom C-series with two cameras optimised for crash and safety testing, offering 4 and 8 megapixel sensors rated to 170G, up to 1180 frames per second, and Phantom Academy application training planned for South Africa next year.

Read more...
SKF extends remanufacturing expertise to bearing clearance modification
SKF South Africa Maintenance, Test & Measurement, Calibration
Using its clearance modification expertise, SKF helped a mining equipment OEM salvage spherical roller bearing inventory that would otherwise have been scrapped, confirming a new capability within its remanufacturing services and avoiding redundant procurement.

Read more...
When maintenance-system compliance starts replacing plant reliability
Wearcheck Maintenance, Test & Measurement, Calibration
WearCheck ARC division manager, Annemie Willer argues that the greatest threat to effective maintenance is no longer a lack of technology, but the gradual replacement of technical judgement by CMMS compliance, leaving no one owning the machine.

Read more...
Economy drive system closes the drive gap in the entry-level segment
Beckhoff Automation Editor's Choice Motion Control & Drives
Beckhoff has launched an economy drive system pairing its new AX1000 servo drive and AM1000 servomotor with the AF1000 dual-axis variable frequency drive on a shared EtherCAT platform, targeting series machines and price-sensitive markets without sacrificing TwinCAT integration or functional safety.

Read more...
Automatic lubrication systems drive mobile mine machine reliability and uptime
SKF South Africa Maintenance, Test & Measurement, Calibration
SKF’s Lincoln P203 progressive lubrication systems are improving reliability and uptime on mobile machines at a Zambian gold mine, with installation of 45 units completing by October 2026.

Read more...
Nitration: the acid you didn’t see coming
Wearcheck Maintenance, Test & Measurement, Calibration
Nitration is as destructive as oxidation in many engines but far less understood. WearCheck technical manager, Steven Lumley explains how nitrogen oxide gases degrade lubricants, why the process is difficult to detect, and what oil analysis can reveal before damage occurs.

Read more...
KSB makes mechanical seals for its own pumps and other brands
Maintenance, Test & Measurement, Calibration
KSB Pumps and Valves is expanding its range of mechanical seals to fit its own pumps and competitor brands. The portfolio covers component and cartridge seals, API 682-compliant systems, slurry and high-pressure seals, and ATEX-certified solutions, supported by refurbishment and field service capabilities.

Read more...
Omniflex delivers ICCP systems in London
Omniflex Remote Monitoring Specialists Maintenance, Test & Measurement, Calibration
Omniflex has supplied impressed current cathodic protection systems for landmark London buildings, protecting reinforced concrete from corrosion and extending the service life of commercial, retail and heritage sites.

Read more...









While every effort has been made to ensure the accuracy of the information contained herein, the publisher and its agents cannot be held responsible for any errors contained, or any loss incurred as a result. Articles published do not necessarily reflect the views of the publishers. The editor reserves the right to alter or cut copy. Articles submitted are deemed to have been cleared for publication. Advertisements and company contact details are published as provided by the advertiser. Technews Publishing (Pty) Ltd cannot be held responsible for the accuracy or veracity of supplied material.




© Technews Publishing (Pty) Ltd | All Rights Reserved