In order to accurately monitor a pollutant of interest, an analyser must be capable of reliably measuring the pollutant in stack gas that is typically hot, saturated with moisture, and dirty.

The Ametek Western Research model 919 is a single gas version of the Model 920 continuous emissions monitor. The 919 is specifically configured for monitoring stack emissions on a concentration basis. With the addition of an optional zirconium oxide sensor, the 919 is capable of monitoring oxygen.

The 919 is a very robust and reliable analyser. Its no-moving-parts, UV-based measurements do not suffer from H2O and CO2 interference. This greatly simplifies sample handling and sample integrity as there is no need for sample drying. As a fully extractive, heated wet basis analyser, the 919's sample system components are simply heated above the dew point of the sample gas. This results in a simpler and more accurate calculation of gas concentration, requiring no corrections for condensed and dissolved components.

The model 919 performs all necessary sample gas and calibration gas flow management, and probe and sample line temperature control. The 919 is a full function continuous emissions monitoring system (CEM), which requires the addition of only a sample probe and sample line to be fully operational. Housing options for the analyser include a cabinet or walk-in shelter built to your specifications.

Hot/wet analysis prevents errors associated with correcting for water vapour and absorption losses in driers.

The hot/wet analysis prevents errors associated with correcting for water vapour and absorption losses in driers. It has an accuracy better than 2,5 ppm SO2 and is able to measure SO2, NO, NO2, H2S, NH3 or a number of other chemicals. The 919 is resistant to H2O and CO2 interference, has automated zero and span gas calibration and provides serial interface with plant DCS. It incorporates flow measurement for emission rate calculations.

Model 919 is suitable for CEM applications in sulphur plants, smelters, power plants, industrial boilers and process heaters.

For more information contact OEN Enterprises, +27 (0)11 675 4447, [email protected], www.oenenterprises.co.za





Share this article:
Share via emailShare via LinkedInPrint this page

Further reading:

Importance of gas analysis in the petrochemical industry
Elemental Analytics Analytical Instrumentation & Environmental Monitoring
Gas analysis plays a critical role in petrochemical operations, supporting process optimisation, product quality and plant safety. As an experienced and expert gas analysis supplier, Elemental Analytics can provide the correct analyser and sample system package to meet individual plant requirements.

Read more...
Fully integrated standalone thunderstorm warning system
Senseca Sensors & Transducers Analytical Instrumentation & Environmental Monitoring
Senseca South Africa has introduced its BTD-1 fully integrated, standalone thunderstorm warning system, which detects lightning by monitoring the background quasi-electrostatic field. The system can generate alerts before the first lightning strike, with a detection raterange of up to 83 km.

Read more...
Environmental monitoring with testo Saveris 1
Analytical Instrumentation & Environmental Monitoring
The testo Saveris 1 environmental monitoring system has been in continuous use since 2010 at Jungbunzlauer, a biotechnology company in Germany, providing seamless temperature and humidity data for audit-ready, GxP-compliant processes across laboratories, warehouses and production areas.

Read more...
Reliability restored through systemic vibration analysis
Wearcheck Analytical Instrumentation & Environmental Monitoring
Condition monitoring specialist, WearCheck uses a variety of testing techniques to enhance reliability in machinery components and prevent failures.

Read more...
Meteorological data logger with up to 32 analogue sensors
Senseca Analytical Instrumentation & Environmental Monitoring
Senseca has introduced its advanced data acquisition system for environmental monitoring, which has a universal data logger for up to 32 analogue, pulse and smart digital sensors.

Read more...
Yokogawa’s free chlorine analyser is gold standard for water treatment utilities
Yokogawa South Africa Analytical Instrumentation & Environmental Monitoring
One of the key factors in ensuring safe drinking water is the accurate monitoring of free chlorine residuals. This is where advanced online analysers, such as Yokogawa’s FC800 free chlorine analyser, are becoming increasingly valuable for water treatment operators and municipal utilities.

Read more...
Cooling tower bleed control
Analytical Instrumentation & Environmental Monitoring
Cooling towers rely on evaporation to remove heat, but this process also concentrates dissolved solids in the system. Left unmanaged, this buildup can lead to scaling, corrosion and fouling, reducing efficiency and increasing maintenance costs.

Read more...
Expanded test laboratory provides polymer users with more information
igus Analytical Instrumentation & Environmental Monitoring
igus has expanded its international testing facilities to accommodate its increasing product portfolio and enable continuous improvement of its product quality.

Read more...
Filters for zero-alcohol wine
Parker Hannifin - Sales Company South Africa Analytical Instrumentation & Environmental Monitoring
The market for zero-alcohol wine is creating fresh opportunities for wine producers, but processing these products creates new contamination challenges. Technical support from an established filtration specialist, such as Parker, can help wineries in overcoming the challenges posed by the increased risk of contamination.

Read more...
Remote monitoring solution for sewage plants
ifm - South Africa Analytical Instrumentation & Environmental Monitoring
With ifm’s remote monitoring solution, you can visualise the condition of the submersible pumps in your sewage plant and diagnose issues before they become serious problems.

Read more...









While every effort has been made to ensure the accuracy of the information contained herein, the publisher and its agents cannot be held responsible for any errors contained, or any loss incurred as a result. Articles published do not necessarily reflect the views of the publishers. The editor reserves the right to alter or cut copy. Articles submitted are deemed to have been cleared for publication. Advertisements and company contact details are published as provided by the advertiser. Technews Publishing (Pty) Ltd cannot be held responsible for the accuracy or veracity of supplied material.




© Technews Publishing (Pty) Ltd | All Rights Reserved