Pneumatics & Hydraulics


Quick-acting couplings

May 2007 Pneumatics & Hydraulics

Quick-acting couplings provide a fast, convenient way to repeatedly connect and disconnect fluid lines.

If a hose or tube in a fluid power system will be connected and disconnected more frequently than once a week, then chances are a quick-acting coupling will pay for itself rapidly by improving productivity. Although simple in concept, many quick-acting couplings are precisely engineered for specific fluid applications. Their widespread use over many years has yielded a diverse variety of designs to serve not only specific, but general industrial applications as well. Consequently, uncertainty can arise as to whether a specific deign is best for a given application.

Regardless of the manufacturer, all quick-acting couplings have some elements in common. All have two parts: a plug and a socket. The plug is the male half and the socket is the female half. When connected properly, these parts seal and lock the joint effectively to contain internal pressures and resist any tensile forces that tend to pull the joint apart. The parts are easily disconnected without tools by disengaging a locking mechanism and separating parts.

Where they are used

The more frequently hoses must be connected and disconnected, the more valuable quick-acting couplings become. They also become more critical as machine productivity increases.

One common application is in assembly workstations, where a worker may have to rapidly switch from impact wrench to drill to riveter. With one quick-acting coupling half on every tool and the mating half on the air line, tool changing is accomplished in seconds. Without the couplings, separate air lines would be needed for each tool; the mass of tools and lines would clutter the workstation and could slow down production.

On hydraulic test stands, quick-acting couplings eliminate bottlenecks by slashing the time required to test each assembly. Just a quick push/pull, and the assembly is ready to test. In contrast, testing time would skyrocket if technicians had to tap into systems using fittings and a wrench for each test procedure.

Valve arrangements

Among the many different designs of quick-acting couplings, either of two types are used for an application. Unvalved types have the advantage of low pressure loss through the coupling, but make no provision to prevent fluid from escaping once the coupling is disconnected. However, if pressure drop in the system must be held to a minimum, and fluid draining from disconnected hoses can be tolerated, unvalved couplings would likely be a designer's first choice.

Obviously, a coupling that does not leak when disconnected would be preferred for probably all applications - all other factors being equal. Incorporating a shutoff valve into one or both halves of the coupling allows fluid to flow through the coupling only when both halves are connected. When the coupling is disconnected, a mechanical link between the coupling halves is broken and causes the valve to close, blocking flow.

When only one coupling half is valved, it usually is located on the source (upstream) end of the joint. Pneumatic systems generally employ this setup: the valved coupling half prevents air loss from the system while the joint is disconnected, the unvalved coupling half allowed downstream air to bleed off.

In hydraulic applications, both coupling halves often are valved. This practice not only minimises fluid leakage, but also limits the amount of air, dirt, and water that can enter the system. When a coupling is disconnected, air can become trapped between valves and enter the system when the joint is reconnected. So if the hydraulic system cannot tolerate air inclusion, special provisions may be necessary to exclude air. To address these concerns, many manufacturers now offer flat-faced couplings that reduce fluid spillage to a drop or less every time the coupling is disconnected. Furthermore, mating surfaces of each coupling half are flush when the coupling is disconnected. This minimises air ingression and wiping the mating surfaces clean before reconnecting them.

Valve considerations

While these valved designs offer the convenience of controlled fluid loss, there are tradeoffs. First of all, valved couplings can generate a significantly higher pressure drop than unvalved designs. The amount of this loss depends on the coupling size and design. Pressure drop can be reduced somewhat by oversizing the coupling. There also may be some deviation in pressure drop from one coupling design to another. If pressure drop is a concern, be sure to check manufacturer's literature for appropriate data.

Other drawbacks to valved couplings include larger size and higher cost. The cost differential will vary according to size and individual design. Generally, couplings designed for low pressure drop, no fluid leakage, and no air entrapment, carry a higher price tag. However, manufacturers point out that the price differential is offset by higher productivity gained by not having to clean up fluid spills.

Coupling types

There are over a dozen common designs of quick-acting couplings. This article covers the six most popular locking mechanisms for fluid power applications.

Ball-lock is the most common design and has the widest range of applications. A group of balls is positioned in holes located around the ID of the socket body. These holes normally are tapered or stepped to reduce their diameter at the socket body ID, so the balls do not fall into the cavity vacated by the plug when the coupling is disconnected.

A spring-loaded sleeve around the socket body's OD forces balls toward the socket body ID. To connect the plug, the sleeve is pushed back, which opens clearance so the balls are free to move outward. Once the plug is in place, releasing the sleeve forces the balls inward against a locking groove on the OD of the plug. To disconnect, pushing the sleeve back provides the balls with clearance to move outward and allow the plug to be removed.

Roller-lock couplings use locking rollers or pins spaced end-to-end in grooves or slots around the socket's ID. As the plug is inserted, a ramp on the plug OD pushes the rollers outward. Once the plug is inserted the prescribed distance, the rollers slip into a retention groove on the plug's OD. Retracting the locking sleeve, which allows the ramp on the plug OD to move the rollers outward, releases the plug.

Pin-lock couplings allow push-to-connect joining using only one hand because the outer sleeve does not need to be retracted to make a connection. In this design, pins are mounted around the socket body ID in a truncated-cone-shaped formation. Pushing the plug into the socket moves pins back and outward, due to a ramp on the plug. Shear across pins locks the plug into the socket. Retracting the springloaded sleeve, which forces the pins back out of the locking groove, releases the plug from the socket.

Flat-face, no-spill couplings have a poppet-style shutoff valve on each mating half. Most limit leakage during uncoupling to only a film of oil on the coupling's mating surfaces and prevent air ingression during coupling. They are also designed for minimum flow restriction, which minimises pressure drop during equipment operation.

Bayonet couplings rely on the familiar twist locking arrangement and are widely used in a variety of applications, especially in plastic couplings for lighter-duty pneumatic equipment. To join the couplings halves, lugs on the OD of the plug engage slots in the socket sleeve as the plug is pushed into the socket. A quick turn locks the lugs into position. Turning the plug in the opposite direction allows the halves to be pulled apart.

Ring-lock couplings use a split ring seated in a groove and slot in the socket. Pushing the plug into position causes a ramp on the plug to spread the ring apart at the split until the ring snaps closed behind a retention shoulder on the plug. Rotating an external sleeve expands the ring, thus releasing it from the retention shoulder so the halves can be pulled apart. This design provides maximum flow in a small envelope for normal shop air applications. A variation of this design uses jaws instead of a split ring to lock the parts together.

Cam-lock couplings lock the socket to the plug when two external levers are folded back against the sides of the socket. These are most common in larger sizes and generally require more spaces than comparable couplings of the same size. Moreover, the locking mechanism can wear if lines are connected or disconnected frequently, which can allow leakage.

Multitube connectors are the fluid equivalent to electrical Cannon-style connectors. They quickly and easily connect or disconnect several tubing lines, while maintaining a correct line orientation and discrete flow paths during reconnection.

Coupling selection

Before selecting a coupling, questions must be answered regarding its expected performance. These questions focus not only on the coupling, but the fluid medium as well. For example, what fluid will flow through the coupling? Characteristics of the fluid - viscosity, corrosivity, etc, - will influence the type of coupling that should be used. Other questions concerning the fluid deal with temperature (high, low, or wide variation), pressure, and flow rate.

Knowing details on the fluid, questions must be answered about the coupling's construction. How often will the coupling be connected and disconnected? What type and diameter of hose or tubing will be used to contain the fluid? Will the coupling or hose be subjected to abuse such as impact from falling objects, severe vibration, or contamination from the environment?

Once these questions have been answered, a preliminary selection of coupling type can be made: one, two, or no shutoff valves, and the type of connect/disconnect mechanism. Keep in mind that one style may offer the greatest convenience in service, but a different model's lower pressure loss may be more desirable for the application.

Materials of construction are another consideration. A wide variety of O-ring and seal materials - elastomers, PTFE, etc, - are available to accommodate most any type of fluid at a wide range of temperatures. Material chosen for the plug and socket also is important. Steel, stainless steel, brass, and aluminium are common. In addition, many parts are made from carbon steel and plated with a corrosion-resistant metal to keep material costs down.

Plastic may be used for many applications if pressure, temperature, and chemical environment permit. Keep in mind that plastic couplings may contain internal metal components that could be corroded by certain types of hydraulic fluid.

Pressure rating relates to values that provide optimum service life and maximum pressure that can be tolerated without failure. Literature should include data for determining pressure drop through the coupling at expected flows and pressures. Many of these calculations are based on flow of water at 60°F (15,6°C).

Keep in mind that pressure drop for oil will be higher because of its higher viscosity. Calculations for air are more complex because a gas's density varies widely with its pressure and temperature. A rule of thumb for air to estimate maximum air flow at 100 psig (689 kPag) inlet and 5 psi (35 kPa) pressure drop is to multiply flow coefficient of the coupling by 25. Often, literature contains more detailed data on maximum air flow at prescribed inlet pressures and pressure drop. Therefore, precise valves for pressure drop for specific couplings should be obtained from the manufacturer.

Also be aware that couplings may be subjected to pressures well above the maximum operating pressure. Sudden shifting of valves or abrupt application of heavy loads can cause system pressure to quickly rise and fall within milliseconds. These pressure spikes often go undetected in a system, but still can damage seals and locking elements of the coupling. Ultimately, then, the coupling would develop leaks, become difficult to disconnect or reconnect, or any combination of these. To prevent these problems from occurring, select a coupling with a pressure rating substantially higher than the anticipated maximum operating pressure.

Depending on the application, the coupling may be subjected to vibration or relative rotation between the mating halves while pressurised. In most cases, these conditions will shorten the expected life of the coupling by causing leakage or difficulties in connecting or disconnecting. Therefore, check with the manufacturer to determine if the coupling will tolerate these conditions.

For more information contact Paul Heney, senior editor, Hydraulics & Pneumatics, 091 216 931 9476, [email protected], www.penton.com

Material for this article was extracted, with permission, from the 2004-2005 Fluid Power Handbook & Directory, copyright 2004, Penton Media, USA.





Share this article:
Share via emailShare via LinkedInPrint this page

Further reading:

CompAir introduces compressed air management solution
Pneumatics & Hydraulics
To maximise savings and extend the lifespan of compressed air systems, CompAir is launching the Compressed Air Management Solution powered by Ecoplant, an intelligent system in the cloud that represents the next level in operational management, and maintain the health

Read more...
Heavy impact, smart control
Axiom Hydraulics Editor's Choice Pneumatics & Hydraulics
Every now and then a project lands on your desk that’s equal parts heavy machinery and fine control - a tantalising mix for any engineer. A client approached Axiom Hydraulics with a project exactly like this.

Read more...
Making lines safer with smarter connection
Hydrasales Pneumatics & Hydraulics
Imagine connecting multiple hydraulic lines or a combination of hydraulic, electrical and grease lines with one single, confident movement. That’s the everyday convenience operators get from Faster’s MultiFaster multi-coupling systems.

Read more...
Achieving clean and dry compressed air
Artic Driers International Pneumatics & Hydraulics
Compressed air is an expensive source of motive power so it makes good sense to supply clean, dry compressed air to your distribution system.

Read more...
Navigating ISO standards in hydraulic cylinder manufacturing
Pneumatics & Hydraulics
For hydraulics professionals, understanding and leveraging ISO standards is a powerful way to ensure quality and gain a competitive edge. Here is a guide to the most critical ISO standards for hydraulic cylinder manufacturing, showing how to use them to your advantage.

Read more...
Hydraulic system upgrades to boost performance and save money
CT Hydraulics (Nqoba) Pneumatics & Hydraulics
Those working with hydraulic or pneumatic systems know that keeping your machinery running at peak performance balances productivity and cost. As systems age, they often become less efficient, requiring more energy and more frequent repairs. The good news is that you don’t always need to invest in an entirely new machine to solve these problems.

Read more...
Top 10 questions about pressure and temperature gauges
SA Gauge Pneumatics & Hydraulics
Some questions never go out of date, and in our industry, a few have been asked for decades. At SA Gauge, we hear them every week. Here are the ten questions we hear most often, and the practical answers that can save time, money and frustration.

Read more...
Gauge maintenance and calibration tips for shutdown or restart periods
SA Gauge Pneumatics & Hydraulics
As the year winds down, many plants across South Africa prepare for the annual shutdown. It’s also the perfect opportunity to give your pressure and temperature gauges the attention they deserve.

Read more...
Axial piston pump series for next-gen hydraulic applications
Pneumatics & Hydraulics
Moog has launched its new AXP Axial Piston Pump Series, a next-generation hydraulic solution engineered to deliver optimal performance, reliability and cost efficiency for industrial applications.

Read more...
The role of analogue gauges in a digital world
SA Gauge Editor's Choice Pneumatics & Hydraulics
With so much focus on digital systems, remote monitoring and automation, it’s easy to assume that traditional analogue gauges have become outdated. Yet if you step into almost any plant, mine or processing facility, you’ll still find them in daily use, quietly doing their job without fuss.

Read more...









While every effort has been made to ensure the accuracy of the information contained herein, the publisher and its agents cannot be held responsible for any errors contained, or any loss incurred as a result. Articles published do not necessarily reflect the views of the publishers. The editor reserves the right to alter or cut copy. Articles submitted are deemed to have been cleared for publication. Advertisements and company contact details are published as provided by the advertiser. Technews Publishing (Pty) Ltd cannot be held responsible for the accuracy or veracity of supplied material.




© Technews Publishing (Pty) Ltd | All Rights Reserved