Fieldbus & Industrial Networking


Versatile protocols

May 2009 Fieldbus & Industrial Networking

Distributed network protocol (DNP3) is a protocol that was developed to allow for flexible, secure communications between devices

To use the GPRS (GPRS/EDGE 3.5G) platform as a communication medium in machine to machine (M2M) applications is often the only cost viable option available. The costs and time delays involved in trenching, radio repeater stations and the theft of cables has forced the recognition of this as a viable and cost-effective alternative.

Applications where M2M via GPRS has been implemented very effectively are:

* Borehole monitoring and control.

* Remote pump stations and pipe lines.

* Remote automated meter reading.

* Environmental monitoring.

One very interesting application used two different network operators at each point for redundancy, using the most available operator at each location to operate a pipeline over country borders with zero downtime of data.

GPRS is an enhancement of the GSM mobile phone network that natively supports the Internet Protocol (IP). Service providers charge for GPRS usage based on the amount of data transferred rather than the duration of the session. This type of technology if correctly used, allows monitoring and control of remote sites at a very low monthly cost – the service charge.

However, most M2M applications using the GPRS platform use non-standard programmed methods to contain the amount of data transmitted for the obvious reason of controlling the data service charge. Especially if analogue values are transmitted, a lot of the options available in the DNP 3 protocol are programmed by hand. Some implementations are more user friendly, but some lead to under and/or over reporting of data. These methods can often not handle variable reporting speeds. Certain analogues, such as vibration, pressure and flow for instance, will be unchanging for a long period of time, but when it really needs reporting, will probably be under-reported.

The DNP 3 protocol is one of the most complete and versatile protocols for communicating among devices for the utility market (ie, water, electricity and gas). Combining these two will decrease service costs, enhance efficiency and increase transmission speed, and turn-around time. For example, how long will it typically take to remotely start/initiate a device or event over GPRS, and get the condition/result feedback?

Some of the requirements for devices supporting DNP 3 protocol are data storage and time stamping. This is just perfect for GPRS communication as delays due to network overloading will not result in any data loss, and the data is buffered in the source device until being accepted by the destination device.

A large amount of devices today support the DNP 3 protocol.

The device capturing the information, on which the DNP 3 protocol is then applied, is normally handled in one of the following categories:

* PLC or RTU (with direct I/O).

* Fault recorders.

* Transducers.

* Meters (ie, electricity meters).

* Relays (ie, protection relays).

* Speciality devices such as battery chargers and protocol analysers.

* Scada’s and scada master.

Telemetry applications, be it for the utility markets, environmental monitoring or control, sub-station monitoring and control, remote metering or remote plants like pump stations, pipe lines or railway lines, are all applications that can leverage these technologies.

For more information contact Jaco Hoogenboezem, SCADAGroup, +27 (0)83 282 5706, [email protected], www.scadagroup.co.za





Share this article:
Share via emailShare via LinkedInPrint this page

Further reading:

EtherCAT interoperability removes industrial networking barriers
Fieldbus & Industrial Networking
Selecting the right communication technology is one of the most important decisions engineers make, and interoperability helps with that decision. Key development tools and standards ensure interoperability among many EtherCAT devices and manufacturers.

Read more...
Condition monitoring to go
Turck Banner Southern Africa Fieldbus & Industrial Networking
Anyone who wants to efficiently monitor the climate in control cabinets will find a comprehensive range of control cabinet monitors for the DIN rail in Turck Banner’s cabinet condition monitoring family.

Read more...
Affordable building management system product range
Fieldbus & Industrial Networking
Schneider Electric has unveiled its EasyLogic Building Management System range, designed for basic building architectures, to the local marketplace. This is a complete and cost-effective range of field controllers and sensors that are both easy to install and scalable.

Read more...
Flexible EtherCAT communication interface for DALI-2
Beckhoff Automation Fieldbus & Industrial Networking
The EL6821 EtherCAT Terminal from Beckhoff allows up to 64 DALI/DALI-2 slaves and 64 DALI-2 input devices to be connected. The TwinCAT 3 System Manager makes it easy to configure and parameterise DALI devices flexibly.

Read more...
EtherCAT-based control technology for building automation
Beckhoff Automation Fieldbus & Industrial Networking
Modern non-residential buildings place many high demands on building automation. This can be optimally implemented with EtherCAT-based control technology from Beckhoff, which provides an efficient central automation architecture thanks to ultra-fast data communication.

Read more...
PC-based control for university studies
Beckhoff Automation Fieldbus & Industrial Networking
The IDEA box developed at Heilbronn University of Applied Sciences is designed to introduce students to the topic of Industry 4.0 in a simple and practical way. At the core of the corresponding demo case is PC-based control from Beckhoff.

Read more...
A new standard in high-speed Ethernet communication
Fieldbus & Industrial Networking
The TXMC897 module from TEWS Technologies supports a range of Ethernet standards and speeds, making it suitable for diverse applications, including the defence, industrial, and IIoT markets.

Read more...
Data-driven battery production
Turck Banner Southern Africa Fieldbus & Industrial Networking
The availability of high-performance batteries at moderate prices is one of the most important factors for the success of electromobility. As a long-standing automation partner to the automotive industry, Turck Banner supports the major battery manufacturers with its know-how.

Read more...
Bring critical temperature data to your condition monitoring system
Turck Banner Southern Africa Fieldbus & Industrial Networking
Data conversion just got easier. Turck Banner converters are compact, simple add-ons that seamlessly fit into your factory applications. You can take various types of signals such as discrete, analogue and many others, and convert them to protocols like IO-link, PICK-IQ, PWM/PFM, and Modbus.

Read more...
Case History 190: Measurement problem ruins level control.
Michael Brown Control Engineering Editor's Choice Fieldbus & Industrial Networking
The widely held belief in many plants that tuning will solve all base layer control problems is completely fallacious. Bad tuning is generally not the main reason for loops to perform badly. It is important when performing optimisation that all elements in a loop are considered, in addition to the control strategy, before even thinking of tuning.

Read more...