Flow Measurement & Control


VA40 WIM with electrical output signal

March 2015 Flow Measurement & Control

Krohne’s new ‘WIM’ option means that the VA40 variable area flowmeter is now available with a 4–20 mA electrical output signal. While the flow rate with these glass devices could previously only be read locally, the 4–20 mA output option allows for transmission of the measured value for control or evaluation purposes. With VA40 WIM version, the height of the float is converted into an electrical signal via a Hall sensor chain. This signal can be used for a PLC/DCS, or to record the measured value over a certain period with a data-logger. Along with each VA40 WIM, Krohne supplies the calibration curve, allowing the customer to assign the exact flow value to any equivalent current value.

VA40 variable area flowmeters are used for the volume flow measurement of liquids or gases. The glass measuring tube enables visual inspection of the medium to evaluate properties such as gas entrainments or colouring. Typical applications include measurement of flushing, purging or inerting gases, heating and cooling circuits, gas measurement in industrial furnaces, or other basic applications in machine building and process industries, where this purely mechanical measuring principle has proven itself for almost 100 years. All connection variants of the VA40 are also available with the WIM option. With the robust stainless steel taps, the maintenance-free device is mounted directly into the pipeline using flange, screw, clamp or hose connections. An installation in hazardous areas according to ATEX II2G Ex ia IIC T6 Gb and ATEX II2D Ex ia IIIC T85°C Db is possible. Retrofitting the WIM option to existing devices is not possible.

For more information contact John Alexander, Krohne SA, +27 (0)11 314 1391, [email protected], www.krohne.com



Credit(s)



Share this article:
Share via emailShare via LinkedInPrint this page

Further reading:

Uncompromising flow rate measurement
Burkert South Africa Flow Measurement & Control
Bürkert’s FLOWave is a hygienic and safe flow measurement solution with many benefits for pharmaceutical or food production processes.

Read more...
Electromagnetic flow measurement
Siemens South Africa Flow Measurement & Control
The SITRANS FM electromagnetic flowmeters from Siemens deliver high-precision volume measurement of electrically conductive liquid applications – from water, wastewater and irrigation to hygienic processes and even mining slurries with magnetic particles.

Read more...
ABB unveils next generation of electromagnetic flowmeters
ABB South Africa Flow Measurement & Control
ABB has launched its latest generation of electromagnetic flowmeters, bringing unmatched accuracy, connectivity and flexibility to industrial and utility applications.

Read more...
Precision measurement for ultra-pure water systems
Flow Measurement & Control
[Sponsored] Ultra-pure water (UPW) is essential in industries where even minor contaminants can impact product quality and process integrity. Anton Paar’s L-Cor Coriolis mass flowmeters provide a highly accurate and hygienic solution by directly measuring the mass of the liquid using the Coriolis effect, ensuring a high level of cleanliness.

Read more...
Inline process solutions for gold mining
Anton Paar Flow Measurement & Control
[Sponsored]The extraction and processing of gold ore requires precision and efficiency to maximise yield and minimise losses. Automation and continuous monitoring of critical process steps are essential to ensure optimal production. Anton Paar offers advanced inline measurement solutions which enable full automation and real-time monitoring of key steps in gold extraction and processing.

Read more...
Magnetic-inductive flow sensor
ifm - South Africa Flow Measurement & Control
The SMF magnetic-inductive flow sensor revolutionises liquid and creamy flow measurement. With IO-Link, it enables digital data transmission, eliminating blind spots in production.

Read more...
Hygienic flow measurement for the food industry
ifm - South Africa Flow Measurement & Control
With the SMF magnetic-inductive flow meter, ifm offers a solution for the hygienic flow measurement of media with variable flow rates through a pipe, such as beer, milk or fruit juice.

Read more...
Case History 197: Bad reboiler temperature control.
Michael Brown Control Engineering Editor's Choice Flow Measurement & Control
It is very important that reboiler temperature controls operate well in petrochemical refineries, or the product quality can really suffer. I was asked to check such a control in a refinery where they were having problems with one of these controls.

Read more...
Precision measurement for ultra-pure water systems
Anton Paar Flow Measurement & Control
[Sponsored] Ultra-pure water (UPW) is essential in industries where even minor contaminants can impact product quality and process integrity. Anton Paar’s L-Cor Coriolis mass flowmeters provide a highly accurate and hygienic solution by directly measuring the mass of the liquid using the Coriolis effect, ensuring a high level of cleanliness.

Read more...
Eliminating splashbacks, spills and early shutoffs in ultra high-flow fuelling
Flow Measurement & Control
Husky Corporation has unveiled the latest innovation in fuelling technology with its newly designed StreamShaper for ultra high-flow applications, which minimises early shutoffs and splashback spills.

Read more...