IT in Manufacturing


Poor heat management in data centre design

October 2025 IT in Manufacturing

In South Africa, many conversations about data centre resilience have tended to centre on power, but backup power is now a given, no credible data centre provider operates without it. The real differentiator lies elsewhere, in the efficiency and precision of the data centre’s design and operations. Managing airflow, controlling humidity, building the most effective and efficient cooling systems, and planning the physical layout are all essential. When these factors are overlooked, the consequences are serious: degraded hardware performance, increased energy consumption, higher operating costs, and potential downtime that disrupts business, resulting in revenue loss and reputational damage. Designing a world-class data centre goes beyond simply keeping servers on during load shedding; it is about ensuring they run efficiently, reliably and within the precise environmental conditions they were built and designed for.

A sensitive ecosystem is a high cost of failure

According to Warren Schooling, sales manager at Digital Parks Africa, many businesses underestimate the impact that temperature and airflow have on performance, efficiency and cost. “Everyone always asks about the power supply to the facility, but hardly anyone asks about cooling, a vitally important metric. Without proper thermal management and thoughtful data centre design, your equipment’s performance will suffer, and the customer ultimately ends up paying more for lower reliability and reduced efficiency.”

Heat is a significant corrosive force in a data centre. It places undue stress on sensitive components like hard drives, solid-state drives (SSDs) and random-access memory (RAM). Furthermore, CPUs are especially vulnerable to excessive temperatures, which accelerate wear and tear and reduce their operational lifespan. This not only increases the risk of system crashes, data corruption and irreversible loss, it can also void any hardware warranties that are in place. For businesses relying on always-on access to services, such as web hosting providers, the knock-on effect can be severe.

“Uptime isn’t just about power, it’s about the quality of the facility, the air, the dust and the heat. Heat is a bigger risk than people realise,” says Jade Benson, managing director at Absolute Hosting. “You can have all the backup power and solar systems you need, but if three out of four HVAC systems fail, you and your business are in serious trouble. We have experienced switches and systems failing from overheating, a challenge we experienced first-hand with a previous provider, which forced us to shut things down to prevent catastrophic loss and damages. This issue underscored just how important it is to have a data centre provider that prioritises maintaining optimal thermal conditions.”


Jade Benson, managing director at Absolute Hosting.

Cooling done wrong can cost you everything

Too often, data centres are built to minimise upfront costs rather than optimise long-term performance. Proper airflow management, humidity control and environmental monitoring are essential, and if a data centre operator is being reactive instead of proactive, it should be a red flag.

Inadequate cooling infrastructure is not just a technical oversight, it becomes a business problem. “Servers are engineered to operate in a specific temperature range. If you run them hot, performance suffers, warranties can be voided and the risk of failure increases. Meanwhile, your operational costs go up because hot machines draw more power. It’s a vicious cycle,” says Schooling.

Data centre design, especially your cooling strategy, must be climate appropriate. It can’t be a one-size-fits-all. “In Johannesburg’s dry air, evaporative cooling works well, but in humid coastal conditions, a different approach is needed. That’s why a dual topology design is optimal, for example using evaporation cooling supported by DX units that can supplement or take over when required. Smart HVAC systems, 2N redundancy and airflow containment help ensure to maintain optimal conditions in any environment,” says Schooling.

“Automation plays a role, but it is not a silver bullet. Sensors can fail. You need human oversight, live monitoring and clear mitigation plans. The data centre environment is a fragile environment and demands surgical precision,” he adds.

Reputation and customer trust at stake

The effects of underperforming thermal design are tangible for businesses like Absolute Hosting that rely on constant uptime and high performance. “When servers overheat, performance drops. We pay a premium for high-quality hardware, and if it is not running at optimal levels, the service we deliver to our customers suffer. The risk is not just data loss. Once you lose a customer due to downtime or poor performance, it is incredibly difficult and costly to win them back,” says Benson.

With artificial intelligence and high-performance computing becoming increasingly standard, thermal loads in data centres are only set to rise. GPUs generate significant heat, and without properly engineered cooling and heat extraction systems, the consequences can include critical hardware failure, prolonged downtime and severe disruption to core business operations.


Warren Schooling, sales manager at Digital Parks Africa.

The bottom line

“As the stakes rise for uptime and performance, data centre cooling must be viewed as a core business issue. What happens inside a data centre directly affects the reliability, speed and cost of the services which businesses rely on every day. As equipment gets more powerful and heat loads increase, it’s no longer enough to ask if there is backup power. Companies need to understand how their infrastructure is built, how it is maintained and whether it is truly designed to handle demand, because by the time something fails, it is already too late,” concludes Benson.

For more information contact Carien Steenkamp, Digital Parks Africa, +27 72 218 6627, carien@dpa.host, www.dpa.host




Share this article:
Share via emailShare via LinkedInPrint this page

Further reading:

The next generation of engineers is building living labs of innovation
Schneider Electric South Africa IT in Manufacturing
Graduate engineers at Schneider Electric East Africa designed, integrated and commissioned the smart building systems in the company’s new Nairobi head office, demonstrating how practical, real-world project experience accelerates engineering capability and confidence.

Read more...
Innodisk launches APEX series edge AI systems for industrial deployment
Vepac Electronics IT in Manufacturing
Innodisk has launched its APEX series edge AI systems, combining hardware, software and system design to simplify industrial AI deployment. The APEX-A100, powered by Qualcomm’s Dragonwing IQ9 processor, delivers up to 100 TOPS with guaranteed availability through 2038.

Read more...
Pilot project to optimise material flow
IT in Manufacturing
WEBER-HYDRAULIK has commissioned autonomous transport robots at its Güglingen site to handle internal material transport between warehouse and assembly areas. The pilot project uses RFID integration and SAP connectivity to automate material flows and reduce manual transport tasks.

Read more...
Accelerating pharmaceutical digital compliance and operational efficiency
Schneider Electric South Africa IT in Manufacturing
Cosmos Limited, one of Kenya’s leading pharmaceutical manufacturers, has partnered with Schneider Electric to implement an integrated monitoring, energy management and digital validation platform that has improved operational visibility, data integrity and regulatory compliance readiness.

Read more...
AI data centres, nature and innovation
Schneider Electric South Africa IT in Manufacturing
Artificial intelligence is driving unprecedented demand for data centre capacity, with liquid cooling now central to managing the heat generated by high-density GPU clusters. Schneider Electric examines how next-generation data centres can balance performance with environmental responsibility.

Read more...
Siemens powers next-generation reusable spacecraft development
Siemens South Africa IT in Manufacturing
A European aerospace startup focused on reusable space systems, has adopted Siemens Xcelerator software to connect engineering disciplines, reduce rework and accelerate spacecraft development, cutting the path from concept to flight hardware to nine months for its orbital demonstration capsule.

Read more...
How to navigate the high-stakes economics of AI infrastructure
IT in Manufacturing
Nearly 60% of data centre operators are expected to adopt liquid cooling within five years as AI workloads drive demand for higher rack densities. Understanding the full financial picture of liquid cooling, from capital investment to long-term operational savings, is now essential.

Read more...
Protecting the digital mine
RJ Connect IT in Manufacturing
As mining becomes increasingly connected and automated, cyber threats are emerging alongside the benefits of digitalisation. RJ Connect and provides rugged networking, edge computing and cybersecurity technologies from MOXA to help protect critical mining operations from evolving attacks.

Read more...
SICK launches AI-powered 3D quality inspection
SICK Automation Southern Africa IT in Manufacturing
SICK has combined deep learning with 3D height data analysis in its Nova machine vision platform.

Read more...
Predictive maintenance is the critical enabler for AI data centre liquid cooling systems
Schneider Electric South Africa IT in Manufacturing
As liquid cooling becomes essential for AI data centres, predictive and condition-based maintenance are emerging as critical enablers of thermal stability. Schneider Electric argues that the infrastructure is already generating the data needed and the question is whether operators are equipped to use it.

Read more...









While every effort has been made to ensure the accuracy of the information contained herein, the publisher and its agents cannot be held responsible for any errors contained, or any loss incurred as a result. Articles published do not necessarily reflect the views of the publishers. The editor reserves the right to alter or cut copy. Articles submitted are deemed to have been cleared for publication. Advertisements and company contact details are published as provided by the advertiser. Technews Publishing (Pty) Ltd cannot be held responsible for the accuracy or veracity of supplied material.




© Technews Publishing (Pty) Ltd | All Rights Reserved