The Chomerics Division of Parker Hannifin has launched two high-performance, high-reliability, fully cured dispensable thermal gels. The new THERM-A-GAP GEL 35VT and THERM-A-GAP GEL 50VT conduct heat away from electronics to heat sinks or enclosures, and perform reliably in both vertical and high-vibration applications.
The VT gels − short for vibration/vertical tackiness − feature innovative materials that have proved highly effective at withstanding rigorous tests involving vertical slump, high vibration and pump out, and also telecommunications thermal verification processes. Long-term reliability is essential as it provides confidence for mission-critical applications that rely on consistent thermal performance over many years of continuous operation.
The tackiness of THERM-A-GAP GEL 35VT and THERM-A-GAP GEL 50 delivers the added benefit of displacing air at thin bond lines and minimising thermal impedance. It is possible to dispense the gels at various bond line thicknesses, typically up to 4 mm, to take up gaps created by assembly or manufacturing tolerances.
These cost-effective new gels are suitable for applications such as telecommunications infrastructure, battery energy storage systems (BESS), ADAS and automotive control modules, automotive sensors and radar, and a variety of other electronic systems in the defence, power, industrial and consumer sectors.
GEL 35VT provides a typical thermal conductivity of 3,5 W/m-K, while GEL 50VT offers 5,2 W/m-K. As with all thermal gels from Parker Chomerics, the formulation of these latest products accommodates today’s high-performance and high-reliability electronics while proving ideal for automated dispensing machines, rework and field repair situations. Both GEL 35VT and GEL 50VT require no mixing or secondary curing in support of easy application and system modifications.
THERM-A-GAP GEL 35VT provides electrical properties that include 200 Vac/mm dielectric strength (Chomerics test method); 1013 Ωcm volume resistivity (ASTM D257); 6,8 dielectric constant at 1000 KHz/0,25 mm thick (ASTM D150); and 0,022 dissipation factor at 1000 kHz/0,25 mm thick (Chomerics).
Based on the same tests, THERM-A-GAP GEL 50VT offers the following electrical properties: 200 Vac/mm dielectric strength; 1014 Ωcm volume resistivity; 5,2 dielectric constant at 1000 KHz/0,76 mm thick; and 0,003 dissipation factor at 1000 kHz/0,76 mm thick.
These RoHS-compliant materials are suitable for use in temperatures from -40 to 150°C (GEL 35VT) and -55 to 200°C (GEL 50VT). Both are available in syringe, cartridge and pail containers, offering standard fill volumes from 10 to 2500 ml.
South African businesses can alleviate energy price crisis
Electrical Power & Protection
While grid instability remains a concern, the immediate and most critical driver of South African commercial and industrial investment in renewable energy is the escalating cost of electricity.
Read more...Real-time modelling is the key to a resilient, bi-directional energy grid Schneider Electric South Africa
Electrical Power & Protection
Utilities and municipalities are facing a challenge as the country’s legacy power grid, engineered for one-way energy delivery from centralised suppliers to end-users, must rapidly evolve to meet a new paradigm.
Read more...Shielding data centre growth from the looming power crunch Schneider Electric South Africa
Electrical Power & Protection
Today’s digital economy is placing unprecedented strain on the power grid. The good news is that these challenges are not insurmountable. By adopting proactive strategies such as alternative power sources, infrastructure planning and software, operators can secure capacity, build resilient facilities and scale sustainably.
Read more...Circuit breaker innovations Schneider Electric South Africa
Electrical Power & Protection
Recent advancements in circuit breaker technology have seen a major step forward in setting new standards for efficiency and sustainability in data centres, industrial and commercial infrastructure.
Read more...Common battery tester errors and what they mean Comtest
Electrical Power & Protection
Battery testers help quickly assess battery health, diagnose issues, and determine whether a battery needs a charge or replacement. This guide covers some of the most common battery tester errors, what they mean, and what can cause them.
Read more...Cathodic protection design considerations that influence ESG outcomes Omniflex Remote Monitoring Specialists
Electrical Power & Protection
Major infrastructure like wharves, bridges, pipelines and tanks are at constant risk of corrosion. David Celine, managing director of cathodic protection specialist Omniflex, explains how CP system design can support ESG commitments, while simultaneously lowering costs and improving maintenance capabilities.
Read more...Recovering condensate and waste heat
Electrical Power & Protection
According to Associated Energy Services, strong partnerships with thermal energy users optimise opportunities to benefit from condensate return. waste heat recovery and the prevention of system contamination.
Read more...Quantum engine powered by particle entanglement
Electrical Power & Protection
In a landmark achievement that signals a new era in energy research, a team of physicists in China has carried out the first successful test of a quantum engine powered by particle entanglement. This technological breakthrough represents a fundamental shift in our approach to energy production.
Read more...Advancing sustainability in South Africa’s fruit industry Schneider Electric South Africa
Electrical Power & Protection
Schneider Electric, together with Technoserve Medium Voltage, has implemented its advanced SF6-free MV switchgear at Two-a-Day situated in Grabouw in the Overberg district.
While every effort has been made to ensure the accuracy of the information contained herein, the publisher and its agents cannot be held responsible for any errors contained, or any loss incurred as a result. Articles published do not necessarily reflect the views of the publishers. The editor reserves the right to alter or cut copy. Articles submitted are deemed to have been cleared for publication. Advertisements and company contact details are published as provided by the advertiser. Technews Publishing (Pty) Ltd cannot be held responsible for the accuracy or veracity of supplied material.