Analytical Instrumentation & Environmental Monitoring


Flexibility for disinfection measuring points

April 2021 Analytical Instrumentation & Environmental Monitoring

Systematic disinfection is an essential step in water treatment and legally required in many areas to protect people and systems from illness or damage. Monitoring of these disinfection processes is a must to comply with limit values and avoid wasting disinfectants. Endress+Hauser’s modular Flowfit CYA27 flow assembly provides a flexible basis for the measurement of disinfection parameters such as chlorine, chlorine dioxide, ozone or bromine, as well as other parameters of liquid analysis such as pH or ORP.

Maximum flexibility with minimum water loss

The CYA27 assembly allows for individual configuration of up to six modules, thereby enabling perfect adaptation to any process requirements. Assembly modules for disinfection sensors and pH/ORP, oxygen or conductivity sensors accommodate relevant measuring points for the analysis of drinking and process water. Further flow or dosing modules ensure a smooth operation of the measuring points.

The growing demand for water and the increasing water scarcity make it necessary to waste as little water as possible, also in bypass measurements. Disinfection sensors installed in the Flowfit CYA27 assembly need a sample flow as low as 5 l/h for a reliable measurement, meaning only a minimum amount of water goes to waste.

Safe measurement and easy maintenance

The new Flowfit system features a status indication light that allows for easy identification of the operating status of the measuring point. This indication light can be used to reflect the status of the flow, showing a red light if the flow is too low. It can also be connected to the alarm relay of the transmitter to indicate the NAMUR status of the measuring point. Operators can see the status at a glance and are able to react to potential errors.

When equipped with the optional cleaning and dosing module, the Flowfit CYA27 assembly requires very low maintenance. The dosing pump module is switched via the connected transmitter, for example the Liquiline multi-parameter transmitter with relay card, enabling automated cleaning cycles and acidification of the medium for specific disinfection process conditions, thus minimising the workload for operating staff.


Credit(s)



Share this article:
Share via emailShare via LinkedInPrint this page

Further reading:

Inspiration for times of change
Endress+Hauser South Africa News
More than 2000 customers, partners and experts gathered in Basel, Switzerland, for the Endress+Hauser Global Forum in April 2026. Under the theme of driving sustainable transformation together, the event combined keynote sessions on strategy, technology and the future of work with practical case studies from across the process industry.

Read more...
Importance of gas analysis in the petrochemical industry
Elemental Analytics Analytical Instrumentation & Environmental Monitoring
Gas analysis plays a critical role in petrochemical operations, supporting process optimisation, product quality and plant safety. As an experienced and expert gas analysis supplier, Elemental Analytics can provide the correct analyser and sample system package to meet individual plant requirements.

Read more...
Optimise sludge treatment and reduce operational costs
Endress+Hauser South Africa Sensors & Transducers
Endress+Hauser’s inline measuring devices, the Proline Teqwave MW 300 and the Proline Teqwave MW 500, determine the total solids content of wastewater directly through microwave transmission.

Read more...
Fully integrated standalone thunderstorm warning system
Senseca Sensors & Transducers Analytical Instrumentation & Environmental Monitoring
Senseca South Africa has introduced its BTD-1 fully integrated, standalone thunderstorm warning system, which detects lightning by monitoring the background quasi-electrostatic field. The system can generate alerts before the first lightning strike, with a detection raterange of up to 83 km.

Read more...
Environmental monitoring with testo Saveris 1
Analytical Instrumentation & Environmental Monitoring
The testo Saveris 1 environmental monitoring system has been in continuous use since 2010 at Jungbunzlauer, a biotechnology company in Germany, providing seamless temperature and humidity data for audit-ready, GxP-compliant processes across laboratories, warehouses and production areas.

Read more...
Reliability restored through systemic vibration analysis
Wearcheck Analytical Instrumentation & Environmental Monitoring
Condition monitoring specialist, WearCheck uses a variety of testing techniques to enhance reliability in machinery components and prevent failures.

Read more...
Level measurement for hygienic applications
Endress+Hauser South Africa Level Measurement & Control
Endress+Hauser’s Liquiphant is considered to be the most reliable and safe point level detector in industrial plants. The latest generation of devices is ready for Industry 4.0 and, with the Liquiphant FTL63, is ideally suited for applications with hygienic requirements.

Read more...
Meteorological data logger with up to 32 analogue sensors
Senseca Analytical Instrumentation & Environmental Monitoring
Senseca has introduced its advanced data acquisition system for environmental monitoring, which has a universal data logger for up to 32 analogue, pulse and smart digital sensors.

Read more...
Yokogawa’s free chlorine analyser is gold standard for water treatment utilities
Yokogawa South Africa Analytical Instrumentation & Environmental Monitoring
One of the key factors in ensuring safe drinking water is the accurate monitoring of free chlorine residuals. This is where advanced online analysers, such as Yokogawa’s FC800 free chlorine analyser, are becoming increasingly valuable for water treatment operators and municipal utilities.

Read more...
Cooling tower bleed control
Analytical Instrumentation & Environmental Monitoring
Cooling towers rely on evaporation to remove heat, but this process also concentrates dissolved solids in the system. Left unmanaged, this buildup can lead to scaling, corrosion and fouling, reducing efficiency and increasing maintenance costs.

Read more...









While every effort has been made to ensure the accuracy of the information contained herein, the publisher and its agents cannot be held responsible for any errors contained, or any loss incurred as a result. Articles published do not necessarily reflect the views of the publishers. The editor reserves the right to alter or cut copy. Articles submitted are deemed to have been cleared for publication. Advertisements and company contact details are published as provided by the advertiser. Technews Publishing (Pty) Ltd cannot be held responsible for the accuracy or veracity of supplied material.




© Technews Publishing (Pty) Ltd | All Rights Reserved