Fieldbus & Industrial Networking


Yokogawa introduces multi-protocol wireless adaptor

October 2014 Fieldbus & Industrial Networking

Yokogawa Electric Corporation has announced a multi-protocol wireless adaptor that enables wired field instruments or analytical sensors to be used as ISA100 Wireless devices, and that support communications based on the HART and RS-485 Modbus standards. To facilitate the introduction of field wireless systems in plants, Yokogawa plans to release additional models that will cover other standards.

Development background

Field wireless systems enable the field devices and the host-level monitoring, control, and other systems in a plant to communicate wirelessly with each other. They have numerous advantages such as allowing the placement of field instruments or analytical sensors in difficult to wire locations, eliminating the need for cables to connect devices and costing less to install. In accordance with its Wireless Anywhere concept, Yokogawa is seeking to promote the plant-wide use of field wireless systems by developing ISA100 Wireless devices such as this multi-protocol wireless adaptor.

Product features

When the multi-protocol wireless adaptor is mounted on a wired field instrument or analytical sensor, the instrument or sensor is able to function as an ISA100 Wireless device. It may be used with any type of wired field instrument or analytical sensor commonly used in plants, including those used to monitor temperature, pressure, liquid level, or vibration, or to detect gas and is compatible with both Yokogawa devices and devices from other vendors. By giving customers a greater range of field instruments and analytical sensors to choose from, Yokogawa expects that this multi-protocol wireless adaptor will greatly facilitate the introduction of field wireless systems.

Support of multiple standards

The first two models are intended for wired HART and RS-485 Modbus communications, both of which are widely used in plants. Yokogawa plans to release models that are compliant with other wired field communications standards such as Foundation fieldbus and Profibus.

Battery power source for field instruments and analytical sensors

The battery in the multi-protocol wireless adaptor can also power the field instrument or analytical sensor, eliminating the need for wiring. As with other Yokogawa field wireless devices, the multi-protocol wireless adaptor uses a large-capacity lithium-ion battery, which is able to power both the multi-protocol wireless adaptor and the field instrument or analytical sensor for a long time. An indicator on the host system shows the estimated remaining days of battery life.

An all-weather model type that has waterproof and dustproof performance and an explosion-protection type that can be used in the presence of inflammable gases are scheduled to be released.

Applications are found in industries such as oil & gas, LNG, refining, petrochemicals, chemicals, power, pulp & paper, pharmaceuticals, foods and steel where it enables wired field instruments and analytical sensors to function as ISA100 Wireless devices.

Yokogawa’s approach to field wireless communications

Yokogawa released the first ISA100 Wireless system devices and wireless pressure and temperature transmitters in July 2010. In addition to enabling sophisticated control techniques in continuous processes, this gave customers a wider range of devices to choose from. In July 2012, Yokogawa released a reliable, large-scale field wireless system for use in plants and is now expanding the range of suitable monitoring and control applications for wireless technologies and devices.

In addition to being highly reliable, suited for a wide range of applications, and expandable, ISA100.11a is compatible with wired communications standards such as Foundation fieldbus, HART, and Profibus. The International Electrotechnical Commission (IEC) is currently considering the adoption of the IEC62734 standard, which is based on ISA100.11a.

ISA100 Wireless is a technology based on the ISA100.11a standard. It includes ISA100.11a-2011 communications, an application layer with process control industry standard objects, device descriptions and capabilities, a gateway interface, infrared provisioning and a backbone router.

In line with the Wireless Anywhere concept, Yokogawa will continue to expand its lineup of ISA100 Wireless solutions and promote the use of field wireless technologies.

For more information contact Johan van der Westhuizen, Yokogawa South Africa, +27 (0)11 831 6300, [email protected], www.yokogawa.com/za



Credit(s)



Share this article:
Share via emailShare via LinkedInPrint this page

Further reading:

EtherCAT interoperability removes industrial networking barriers
Fieldbus & Industrial Networking
Selecting the right communication technology is one of the most important decisions engineers make, and interoperability helps with that decision. Key development tools and standards ensure interoperability among many EtherCAT devices and manufacturers.

Read more...
Condition monitoring to go
Turck Banner Southern Africa Fieldbus & Industrial Networking
Anyone who wants to efficiently monitor the climate in control cabinets will find a comprehensive range of control cabinet monitors for the DIN rail in Turck Banner’s cabinet condition monitoring family.

Read more...
Affordable building management system product range
Fieldbus & Industrial Networking
Schneider Electric has unveiled its EasyLogic Building Management System range, designed for basic building architectures, to the local marketplace. This is a complete and cost-effective range of field controllers and sensors that are both easy to install and scalable.

Read more...
Flexible EtherCAT communication interface for DALI-2
Beckhoff Automation Fieldbus & Industrial Networking
The EL6821 EtherCAT Terminal from Beckhoff allows up to 64 DALI/DALI-2 slaves and 64 DALI-2 input devices to be connected. The TwinCAT 3 System Manager makes it easy to configure and parameterise DALI devices flexibly.

Read more...
EtherCAT-based control technology for building automation
Beckhoff Automation Fieldbus & Industrial Networking
Modern non-residential buildings place many high demands on building automation. This can be optimally implemented with EtherCAT-based control technology from Beckhoff, which provides an efficient central automation architecture thanks to ultra-fast data communication.

Read more...
PC-based control for university studies
Beckhoff Automation Fieldbus & Industrial Networking
The IDEA box developed at Heilbronn University of Applied Sciences is designed to introduce students to the topic of Industry 4.0 in a simple and practical way. At the core of the corresponding demo case is PC-based control from Beckhoff.

Read more...
A new standard in high-speed Ethernet communication
Fieldbus & Industrial Networking
The TXMC897 module from TEWS Technologies supports a range of Ethernet standards and speeds, making it suitable for diverse applications, including the defence, industrial, and IIoT markets.

Read more...
Data-driven battery production
Turck Banner Southern Africa Fieldbus & Industrial Networking
The availability of high-performance batteries at moderate prices is one of the most important factors for the success of electromobility. As a long-standing automation partner to the automotive industry, Turck Banner supports the major battery manufacturers with its know-how.

Read more...
Bring critical temperature data to your condition monitoring system
Turck Banner Southern Africa Fieldbus & Industrial Networking
Data conversion just got easier. Turck Banner converters are compact, simple add-ons that seamlessly fit into your factory applications. You can take various types of signals such as discrete, analogue and many others, and convert them to protocols like IO-link, PICK-IQ, PWM/PFM, and Modbus.

Read more...
Case History 190: Measurement problem ruins level control.
Michael Brown Control Engineering Editor's Choice Fieldbus & Industrial Networking
The widely held belief in many plants that tuning will solve all base layer control problems is completely fallacious. Bad tuning is generally not the main reason for loops to perform badly. It is important when performing optimisation that all elements in a loop are considered, in addition to the control strategy, before even thinking of tuning.

Read more...