Emerson has announced the release of two new-to-the-world technologies for the Crosby J-Series pressure relief valve (PRV) product line. The first is the Balanced Diaphragm, which eliminates the need for bellows in PRVs, while providing balanced operation against backpressure to lower cost of ownership and enhance performance. The second technology is Bellows Leak Detection, enabling remote detection of bellows ruptures in PRVs, with the capability to reduce and accurately calculate volumetric emissions in real time.
Where backpressure is present, spring-loaded PRVs often utilise bellows to ensure balanced operation. Data analysis from 30 000 PRV service records across different industries and valve brands shows a bellows failure rate between 2 and 6%. In other words, a plant with 1000 bellows PRVs may have between 20 to 60 PRVs continuously operating with damaged bellows. The most common causes of bellows failures are excessive backpressure and rapid cycling. Ruptured bellows will cause fugitive emissions and may prevent valve operation at the designed set pressure, with the risk of catastrophic overpressure events.
The Crosby Balanced Diaphragm can replace bellows in PRV applications to address these and other issues. Its innovative design extends the backpressure limits from 60 to 80% and increases the Kb backpressure correction factor by up to 15%, expanding the application range of spring-loaded PRVs. The Kb factor is used to size PRVs when they are installed in closed systems subject to backpressure. Extending the backpressure limit and increasing the Kb factor often permits the use of smaller valves. In addition, diaphragms are inherently more resilient than bellows for higher backpressures and rapid cycling applications. Upgrading to a Balanced Diaphragm therefore lowers maintenance costs, improves reliability, and increases stability.
The second technology, Bellows Leak Detection, addresses the problem of bellows failures, which are challenging to detect and often remain unnoticed for years until removal of the valve for periodic service. Leak detection and repair (LDAR) programmes may include PRVs, but their target sources for leakage detection are flanges or valve seats, so bellows ruptures will generate fugitive emissions through the PRV bonnet vent that may not be in the LDAR scope. In addition, PRV installations are often difficult to access and in hazardous locations, making leak detection difficult.
The Bellows Leak Detection solution is a safer and more efficient method for detecting bellows failures and emissions. It consists of a backup piston and a Rosemount wireless or wired pressure transmitter. The backup piston can reduce emissions by over 90% in the event of a bellows rupture, because it has a much smaller clearance than a standard bonnet vent, and it ensures balanced operation. The pressure transmitter provides instant timestamped notification of bellows failure and emissions volume data in real time.
Upgrade kits for existing Crosby J-Series PRVs are available for both new technologies, and new PRVs can be purchased with these features pre-installed.
“With the growing global emphasis on sustainability, an increasing number of PRVs that currently vent to the atmosphere will require connections to flare systems, to curb emissions. The resulting higher backpressures will push the limits of existing PRV designs, and the Balanced Diaphragm and Bellows Leak Detection breakthrough innovations will help our customers address this need,” said Judson Duncan, president of Emerson’s pressure management business.
ENERGYValves expands operations
Valves, Actuators & Pump Control
ENERGYValves is expanding its operations with a new facility in Cape Town. The new premises will significantly enhance the company’s capacity to serve the Cape Town market and surrounding areas.
Read more...Pumps lead the way with advanced technology
Valves, Actuators & Pump Control
The KSB GIW MDX pump has consistently represented a major leap forward in mill duty applications, with KSB relying on customer feedback to improving the design continuously.
Read more...Wireless leak detection valve
Valves, Actuators & Pump Control
Designed to prevent water leakage by automatically shutting off the water supply when a leak is detected, the Runxin F104 wireless leak detection valve is one of the latest offerings from Allmech.
Read more...Ball valves and actuators optimise HVAC performance Schneider Electric South Africa
Valves, Actuators & Pump Control
Schneider Electric offers the full range of innovative SpaceLogic and EasyLogic ball valves and actuators. These cutting-edge products are designed to optimise HVAC system performance, ensuring comfort and energy efficiency in commercial and residential buildings.
Read more...Alfa Laval expands hygienic valve portfolio
Valves, Actuators & Pump Control
Alfa Laval is expanding its hygienic valve portfolio by introducing the Unique SSV pressure relief valve and the Leakage Detection butterfly valve, alongside new smaller sizes of the Unique Mixproof CIP and Unique Mixproof process valves.
Read more...Preparing pump systems for adverse weather conditions
Valves, Actuators & Pump Control
As the severity of storms in South Africa increases, so has the rush of sediment-laden water become a major issue and a significant challenge for irrigation. When sediment levels rise to just 10 grams per litre or more, the risk of pump wear and dam silting increases dramatically.
Read more...High-flow solenoid valve Emerson Automation Solutions
Valves, Actuators & Pump Control
Emerson has introduced the new ASCO Series 327C solenoid valve, which features a direct-acting, high-flow design that provides superior flow-to-power ratio. It permits high flows at minimum power levels, making it ideal for use in power plants, refineries, and chemical processing facilities.
Read more...Proportional cartridge valve series is the fastest in its class
Valves, Actuators & Pump Control
Parker Hannifin is introducing the enhanced version of the proportional cartridge throttle valve series, TFP. The new pilot valve further reduces the step response times by up to 30%, making the TFP the fastest valve in its class.
Read more...Proportional cartridge valve series is the fastest in its class
Valves, Actuators & Pump Control
Parker Hannifin is introducing the enhanced version of the proportional cartridge throttle valve series, TFP. The new pilot valve further reduces the step response times by up to 30%, making the TFP the fastest valve in its class.
Read more...Inspection system for leak detection in valves in hazardous areas Extech Safety Systems
Valves, Actuators & Pump Control
Leaking valves in industrial plants not only lead to loss, safety risks and possible contamination and pollution, but also result in high economic costs. Therefore, valves in hazardous areas require regular proper inspection and preventive maintenance to ensure their functionality.
While every effort has been made to ensure the accuracy of the information contained herein, the publisher and its agents cannot be held responsible for any errors contained, or any loss incurred as a result. Articles published do not necessarily reflect the views of the publishers. The editor reserves the right to alter or cut copy. Articles submitted are deemed to have been cleared for publication. Advertisements and company contact details are published as provided by the advertiser. Technews Publishing (Pty) Ltd cannot be held responsible for the accuracy or veracity of supplied material.