Flow Measurement & Control


Key factors for picking the optimal flowmeter

July 2021 Flow Measurement & Control

Flowmeters play a pivotal role in many applications, but some may underperform if they’re not the best match for a process. Making assumptions about a flowmeter going into an oil or gas application can lead to an expensive mistake, especially in high-pressure situations. While a variety of factors impact meter performance, the most common culprits are flawed sizing and failing to choose the most appropriate technology.

By more closely accounting for these and other variables – and not going into the evaluation fixed on a specific meter technology – operators can ensure their future flowmeter acquisitions are better suited for the job.

Pay close attention to sizing

Sizing is an issue because meters tend to be designed to potential maximum flows instead of actual operating flow rates. Is a meter the proper size for the flow rate, pressure and temperature at which it will typically be operating? Because gas is compressible, for example, sizing a meter for maximum design pressure will provide a flow rate in standardised volumes that appears much different than it would be at normal operating pressure. In that case, selecting a flow meter to handle 135 bar based on the pipeline design, even though it will really operate at 35 bar, will result in a meter that is substantially oversized for the application.

To mitigate these types of sizing issues, ask the vendor for a sizing report or for software to perform the sizing. Plug all the flow variables – fluid type, flow rate, pressure, temperature, viscosity, compressibility, and density – into the software. It will provide recommended technologies as well as an estimate of the devices’ performance to help select the most suitable meter.

However, sizing software can only go so far, as another common issue is not selecting the technology that’s the optimal fit for an application. For example, if there are corrosion inhibitors in a fluid, it would be inappropriate to use an electromagnetic meter since the additive may inadvertently be coating the sensor electrodes and thereby affecting the sensitivity of the device to flow changes. Account for any special considerations, such as the potential explosiveness or corrosiveness of what’s being measured. Additionally, are there any electrical or hazardous materials approvals required for the technology to fit in an installation? Asking these types of questions will help you to determine material compatibility and narrow down the most appropriate options.

Other variables to watch

While proper sizing and choice of meter based on materials is critical, there are other fundamentals to consider when evaluating flow meters. These include:

• Be clear on what is required when it comes to accuracy, repeatability and pressure drops at nominal operating conditions. A greater pressure drop might be acceptable in some settings, but not in others. Most manufacturers’ sizing software will provide several meter options that span a range of accuracy and pressure drops.

• Have a clear understanding of what’s being measured and its overall state. While this seems straightforward, there can be confusion in some instances. This may impact where and how you choose to install the meter, so consult the manufacturer if these types of conditions apply.

• Mechanically, what kind of flanges or end connections will be needed to mount the instrument? If the new flowmeter is replacing an existing meter, understand the dimensions of what’s being replaced. For example, what will be required to adapt a new meter selected as a replacement for a mechanical device with a narrow facing.

• Have a clear understanding of the power requirements, environmental conditions and how the meter will connect to other devices. A meter tied into a control system might elicit a different set of recommendations from a vendor than one that will be operating independently or remotely connected to a scada system.

Finding an optimal flowmeter solution depends on knowing as much as possible about the application. By asking the right questions and taking these variables into consideration you are more likely to find the best device for the application.


Credit(s)



Share this article:
Share via emailShare via LinkedInPrint this page

Further reading:

Mastering inline LNG flow monitoring
Flow Measurement & Control
[Sponsored] As global demand for cleaner, more flexible energy sources continues to rise, liquefied natural gas (LNG) stands at the forefront of the energy transition. Engineered for excellence in cryogenic environments, the Anton Paar L-Cor 8000 flowmeter redefines inline LNG flow monitoring.

Read more...
Magnetic-inductive flowmeter with effective compact electronics and IO-link
Instrotech Flow Measurement & Control
KOBOLD has combined two of its proven components, the successful type MIK magnetic-inductive flow meter and the popular U-PACE compact electronics, creating an exciting new compact flow instrument at the best price.

Read more...
Dosing chlorine gas safely and sustainably
Flow Measurement & Control
Chlorine gas is central to a range of industrial processes but is highly dangerous. The solution is the deployment of a system solution for chlorination from Lutz-Jesco.

Read more...
Oil monitoring solution drives performance gains for paper mill
SKF South Africa Flow Measurement & Control
By integrating real-time monitoring with precise flow control, SKF’s Flowline oil monitor meters have significantly improved the flow rate control and performance of oil circulation lubrication systems installed on a paper mill.

Read more...
Flow measurement in mobile applications
ifm - South Africa Flow Measurement & Control
The SU Puresonic Mobile ultrasonic sensor from ifm is characterised by its displayless design and high temperature resistance. It is ideal for mobile applications and processes with permanent media temperatures of up to 120°C.

Read more...
Optimising water quality in a building cooling system
ifm - South Africa Flow Measurement & Control
A leading company in industrial water management has installed water treatment systems that not only optimise water quality but also help customers to improve their processes, thanks to the new insights and actions that can be generated based on the process data collected.

Read more...
New uncompromisingly simple flowmeter line for processes
Endress+Hauser South Africa Flow Measurement & Control
The demand for simplicity in commissioning, operation and maintenance in industrial process plants has increased significantly in recent years. The new Proline 10 range of flowmeters from Endress+Hauser meets this requirement without compromise, because simplicity is the top priority.

Read more...
Rotork joins Rockwell Automation’s Technology Partner Programme
Flow Measurement & Control
Rotork has entered into the Rockwell Automation Technology Partner Programme, marking a significant step in expanding the company’s presence within the industrial automation landscape.

Read more...
Loop signature 29: Averaging or surge level control
Editor's Choice Flow Measurement & Control
There are many processes where it is undesirable for the load to suddenly change quickly, for example in the paper industry. Examples of level control have involved reasonably fast tuning. An example of a level loop tuned this way and responding to a step change in setpoint is given.

Read more...
A reliable water supply: The make or break in building metros across South Africa
VEGA Controls SA Flow Measurement & Control
South Africa’s urban centres encounter substantial water supply challenges. Maintaining stable water infrastructure is essential for the health, economic vitality and well-being of communities.

Read more...









While every effort has been made to ensure the accuracy of the information contained herein, the publisher and its agents cannot be held responsible for any errors contained, or any loss incurred as a result. Articles published do not necessarily reflect the views of the publishers. The editor reserves the right to alter or cut copy. Articles submitted are deemed to have been cleared for publication. Advertisements and company contact details are published as provided by the advertiser. Technews Publishing (Pty) Ltd cannot be held responsible for the accuracy or veracity of supplied material.