Flow Measurement & Control


Key factors for picking the optimal flowmeter

July 2021 Flow Measurement & Control

Flowmeters play a pivotal role in many applications, but some may underperform if they’re not the best match for a process. Making assumptions about a flowmeter going into an oil or gas application can lead to an expensive mistake, especially in high-pressure situations. While a variety of factors impact meter performance, the most common culprits are flawed sizing and failing to choose the most appropriate technology.

By more closely accounting for these and other variables – and not going into the evaluation fixed on a specific meter technology – operators can ensure their future flowmeter acquisitions are better suited for the job.

Pay close attention to sizing

Sizing is an issue because meters tend to be designed to potential maximum flows instead of actual operating flow rates. Is a meter the proper size for the flow rate, pressure and temperature at which it will typically be operating? Because gas is compressible, for example, sizing a meter for maximum design pressure will provide a flow rate in standardised volumes that appears much different than it would be at normal operating pressure. In that case, selecting a flow meter to handle 135 bar based on the pipeline design, even though it will really operate at 35 bar, will result in a meter that is substantially oversized for the application.

To mitigate these types of sizing issues, ask the vendor for a sizing report or for software to perform the sizing. Plug all the flow variables – fluid type, flow rate, pressure, temperature, viscosity, compressibility, and density – into the software. It will provide recommended technologies as well as an estimate of the devices’ performance to help select the most suitable meter.

However, sizing software can only go so far, as another common issue is not selecting the technology that’s the optimal fit for an application. For example, if there are corrosion inhibitors in a fluid, it would be inappropriate to use an electromagnetic meter since the additive may inadvertently be coating the sensor electrodes and thereby affecting the sensitivity of the device to flow changes. Account for any special considerations, such as the potential explosiveness or corrosiveness of what’s being measured. Additionally, are there any electrical or hazardous materials approvals required for the technology to fit in an installation? Asking these types of questions will help you to determine material compatibility and narrow down the most appropriate options.

Other variables to watch

While proper sizing and choice of meter based on materials is critical, there are other fundamentals to consider when evaluating flow meters. These include:

• Be clear on what is required when it comes to accuracy, repeatability and pressure drops at nominal operating conditions. A greater pressure drop might be acceptable in some settings, but not in others. Most manufacturers’ sizing software will provide several meter options that span a range of accuracy and pressure drops.

• Have a clear understanding of what’s being measured and its overall state. While this seems straightforward, there can be confusion in some instances. This may impact where and how you choose to install the meter, so consult the manufacturer if these types of conditions apply.

• Mechanically, what kind of flanges or end connections will be needed to mount the instrument? If the new flowmeter is replacing an existing meter, understand the dimensions of what’s being replaced. For example, what will be required to adapt a new meter selected as a replacement for a mechanical device with a narrow facing.

• Have a clear understanding of the power requirements, environmental conditions and how the meter will connect to other devices. A meter tied into a control system might elicit a different set of recommendations from a vendor than one that will be operating independently or remotely connected to a scada system.

Finding an optimal flowmeter solution depends on knowing as much as possible about the application. By asking the right questions and taking these variables into consideration you are more likely to find the best device for the application.


Credit(s)



Share this article:
Share via emailShare via LinkedInPrint this page

Further reading:

Hygienic ultrasonic flow sensor
ifm - South Africa Flow Measurement & Control
The SU Puresonic Hygienic ultrasonic sensor from ifm detects flows of conductive and non-conductive media with high precision.

Read more...
VEGA pressure instrumentation supports resilient water network management
VEGA Controls SA Pressure Measurement & Control Flow Measurement & Control
As rapid urbanisation and climate pressures strain water networks across Africa, accurate real-time pressure monitoring has become a strategic necessity. VEGA’s pressure instrumentation helps utilities reduce losses, protect infrastructure and meet sustainability targets.

Read more...
Reducing fluid control and automation complexity in pharma process development
Flow Measurement & Control
Designing and building pharmaceutical processes or skids demands close coordination between mechanical, electrical, instrumentation and automation engineering teams.

Read more...
Flow imaging microscopy for the early detection of harmful algal blooms
Yokogawa South Africa Flow Measurement & Control
Yokogawa’s advanced flow imaging microscopy technology, FlowCam is helping utilities move from reactive treatment to proactive prevention of harmful algal blooms in reservoirs, dams and freshwater sources.

Read more...
Never waste a drop
Flow Measurement & Control
Manufacturers of pumps, valves and related equipment have an important role to play when systems for water are being designed or upgraded and should be included at every stage of a project to ensure that the work is carried out within the equipment’s capabilities.

Read more...
Ultrasonic flow meters
ifm - South Africa Flow Measurement & Control
The ultrasonic flow meter of the SU series from ifm - South Africa monitors liquid media such as water, glycol solutions or industrial oils. It detects the three process categories volumetric flow quantity, consumed quantity and medium temperature.

Read more...
How utilities identify water losses in Northern Europe
Flow Measurement & Control
Norwegian leak detection specialist, Ovarro outlines how municipalities are responding to hidden water loss using acoustic monitoring and analysis tools that provide early indications of developing leaks.

Read more...
Senix sensors provide flood warnings
Instrotech Flow Measurement & Control
To create the world’s most sophisticated flood monitoring and forecasting system, the US State of Iowa’s Flood Centre (IFC) uses more than 200 Senix ToughSonic 30 and ToughSonic 50 ultrasonic sensors to measure water levels in streams across the state.

Read more...
Mastering inline LNG flow monitoring
Flow Measurement & Control
[Sponsored] As global demand for cleaner, more flexible energy sources continues to rise, liquefied natural gas (LNG) stands at the forefront of the energy transition. Engineered for excellence in cryogenic environments, the Anton Paar L-Cor 8000 flowmeter redefines inline LNG flow monitoring.

Read more...
Magnetic-inductive flowmeter with effective compact electronics and IO-link
Instrotech Flow Measurement & Control
KOBOLD has combined two of its proven components, the successful type MIK magnetic-inductive flow meter and the popular U-PACE compact electronics, creating an exciting new compact flow instrument at the best price.

Read more...









While every effort has been made to ensure the accuracy of the information contained herein, the publisher and its agents cannot be held responsible for any errors contained, or any loss incurred as a result. Articles published do not necessarily reflect the views of the publishers. The editor reserves the right to alter or cut copy. Articles submitted are deemed to have been cleared for publication. Advertisements and company contact details are published as provided by the advertiser. Technews Publishing (Pty) Ltd cannot be held responsible for the accuracy or veracity of supplied material.




© Technews Publishing (Pty) Ltd | All Rights Reserved