IS & Ex


Illuminated E-stops with diagnostics

March 2021 IS & Ex

Eliminate the time, hassle, and expense of running designated cabling between each device and the control panel in order to collect diagnostic data. In-Series Diagnostics runs through up to 32 devices on a single 4-pin cable to the control panel, with only two wires running to the controller and two others for power. Users can easily add, move, or remove devices at any stage of a machine’s lifecycle by simply updating the configuration in the software and implementing the changes indicated in the wiring diagram. The one-piece design with M12 connection of the E-stop buttons further simplifies installation, especially when deploying multiple buttons in a system.

Data is collected from up to 32 compatible devices in each In-Series Diagnostics chain. Using an HMI or similar device, users can view the status and location of each device and drill into the data to determine the unique tag value, internal temperature, voltage, and other device-level details.

Operates at the highest level of safety (PL-e)

Up to 32 In-Series Diagnostic devices connected in series achieve up to Category 4, PL-e, or SIL CL 3 safety ratings. Outputs on each device are continuously monitored to detect any faults, including short circuits. This design eliminates the possibility of fault masking at any point in the system. The illuminated E-stop with ISD is the latest member of the ISD family of products, which includes RFID door switches and the SC10 hybrid relay/controller.

In-Series Diagnostics provides easy access to device-level data that can be used to prevent potential problems and quickly correct issues that stop operations. Using an HMI or similar device, staff can view the status and location of each device and drill into the data to determine system health and performance. The system can even be configured to alert, direct, and instruct staff when a critical event occurs to get equipment back up and running as soon as possible.

Applications

E-stop buttons with ISD can be used to provide safe start and stop functions on applications with multiple E-stops and/or multiple safety start-stop functions where local or remote diagnostics feedback is important to reduce and prevent downtime, for instance: assembly stations and robotics, conveying lines, packaging machines, and rotating equipment.


Credit(s)



Share this article:
Share via emailShare via LinkedInPrint this page

Further reading:

Cybersecurity for potentially explosive areas
Phoenix Contact IS & Ex
The Cellulink outdoor cellular router product range from Phoenix Contact is being extended. New versions are now also available that have been specially developed for use in Zone 2 potentially explosive areas.

Read more...
Windows tablets for hazardous areas
Extech Safety Systems IS & Ex
i.safe Mobile has expanded its intrinsically safe product range with the launch of the IS945.x series rugged Windows tablets, designed for use in hazardous and demanding industrial environments.

Read more...
Strengthening safety, skills and operational resilience during strategic shutdowns in petrochemical plants
IS & Ex
In the petrochemical industry, shutdowns are high-stakes operations that play a vital role in maintaining plant performance, safety and compliance. A well-executed shutdown helps prevent unplanned outages, minimises costly downtime and keeps operations running efficiently long after production resumes.

Read more...
Kollmorgen expands hazardous location portfolio with AKME servo motors
IS & Ex
With the most compact sizes, high power density, a wide range of mounting and encoder options, and ATEX and IECEx certifications, Kollmorgen’s new AKME servo motors deliver exceptional performance and versatility in hazLoc applications.

Read more...
Hazardous area inspections
Extech Safety Systems IS & Ex
The i.safe MOBILE IS940.1 tablet from Extech delivers the performance of a modern Android device, but in a package designed from the ground up for hazardous areas.

Read more...
Unified endpoint management in hazardous industrial environments
Extech Safety Systems IS & Ex
The strategic integration of SafeUEM‘s comprehensive end-point management platform with i.safe MOBILE‘s certified intrinsically safe devices delivers a unified solution specifically engineered to address the challenges of managing technology in hazardous industrial settings.

Read more...
A lesson in the history and evolution of industrial safety systems
Schneider Electric South Africa IS & Ex
One only has to briefly page through the annals of our industrial history to come across truly hair-raising stories of safety systems failing or underperforming with catastrophic repercussions. Fortunately, industrial safety in the last few decades has undergone some truly profound development.

Read more...
Windows tablets for Zone 1/21, Zone 2/22 and mining
Extech Safety Systems IS & Ex
Extech is expanding its portfolio with the Windows-based tablets IS945.1, IS945.2, and IS945.M1. For the first time, EX certification is combined with full Windows compatibility, without compromising on software or security.

Read more...
Certified safe power for hazardous industrial environments
Conical Technologies IS & Ex
When working in high-risk environments like oil and gas, petrochemical plants or other hazardous industrial zones, safety isn’t just important, it’s essential. That’s why Traco Power developed the TIB-EX series of DIN rail power supplies, purpose-built to deliver reliable power even in the toughest conditions.

Read more...
Parker strengthens explosion safety
IS & Ex
Parker Hannifin has announced that its 37 mm Ex d m coils have attained new ATEX and IECEx Type Examination Certificates according to the latest explosion protection standards.

Read more...









While every effort has been made to ensure the accuracy of the information contained herein, the publisher and its agents cannot be held responsible for any errors contained, or any loss incurred as a result. Articles published do not necessarily reflect the views of the publishers. The editor reserves the right to alter or cut copy. Articles submitted are deemed to have been cleared for publication. Advertisements and company contact details are published as provided by the advertiser. Technews Publishing (Pty) Ltd cannot be held responsible for the accuracy or veracity of supplied material.




© Technews Publishing (Pty) Ltd | All Rights Reserved