Flow Measurement & Control


Differential pressure flowmeter

October 2012 Flow Measurement & Control

The Durag D-FL 100 flow monitor continuously determines flow velocity and flow rate in exhaust gas. The flow is calculated from the differential pressure in a flow probe with two measuring chambers. The flow in the duct builds up a pressure difference between the two separate chambers of the probe and this pressure differential is proportional to the square of the gas speed. To calculate a normalised flow, input for differential pressure, absolute pressure and temperature is used. The flow monitor measures across the cross-section of the duct.

Alarm levels are pre-selectable and any alarms are indicated inertia free, permitting the necessary interventions on the plant control system so as to comply with prescribed emission limit values. The D-FL-100 units are available in two types: the D-FL-100-I is designed for measuring flow without temperature and pressure compensation while the D-FL-100-II measures flow with temperature and pressure compensation.

The flow volume can be converted from operational to standard conditions by the D-FL-100-10 microprocessor evaluation unit, which has been provided with two additional 0–20 mA current inputs for a temperature probe and a pressure probe. If an emission evaluation computer is available, the evaluation unit is not required. Special designs are available for use in aggressive exhaust gases. A hastelloy flow probe is recommended for power, chemical and paper plants. For operating temperatures over 600°C, an inconel flow probe is available.

The measuring ranges offered are 400–2000 mm, 2000–4000 mm and >4000 mm. Exhaust gas temperature can be up to 320°C above the exhaust gas dew point. An automatic backflow purging feature is available as an option.

For more information contact Mike Andrews, OEN Enterprises, 27 (0)11 675 4447, [email protected], www.oenenterprises.co.za





Share this article:
Share via emailShare via LinkedInPrint this page

Further reading:

Rotork joins Rockwell Automation’s Technology Partner Programme
Flow Measurement & Control
Rotork has entered into the Rockwell Automation Technology Partner Programme, marking a significant step in expanding the company’s presence within the industrial automation landscape.

Read more...
Loop signature 29: Averaging or surge level control
Editor's Choice Flow Measurement & Control
There are many processes where it is undesirable for the load to suddenly change quickly, for example in the paper industry. Examples of level control have involved reasonably fast tuning. An example of a level loop tuned this way and responding to a step change in setpoint is given.

Read more...
A reliable water supply: The make or break in building metros across South Africa
VEGA Controls SA Flow Measurement & Control
South Africa’s urban centres encounter substantial water supply challenges. Maintaining stable water infrastructure is essential for the health, economic vitality and well-being of communities.

Read more...
Uncompromising flow rate measurement
Burkert South Africa Flow Measurement & Control
Bürkert’s FLOWave is a hygienic and safe flow measurement solution with many benefits for pharmaceutical or food production processes.

Read more...
Electromagnetic flow measurement
Siemens South Africa Flow Measurement & Control
The SITRANS FM electromagnetic flowmeters from Siemens deliver high-precision volume measurement of electrically conductive liquid applications – from water, wastewater and irrigation to hygienic processes and even mining slurries with magnetic particles.

Read more...
ABB unveils next generation of electromagnetic flowmeters
ABB South Africa Flow Measurement & Control
ABB has launched its latest generation of electromagnetic flowmeters, bringing unmatched accuracy, connectivity and flexibility to industrial and utility applications.

Read more...
Precision measurement for ultra-pure water systems
Flow Measurement & Control
[Sponsored] Ultra-pure water (UPW) is essential in industries where even minor contaminants can impact product quality and process integrity. Anton Paar’s L-Cor Coriolis mass flowmeters provide a highly accurate and hygienic solution by directly measuring the mass of the liquid using the Coriolis effect, ensuring a high level of cleanliness.

Read more...
Inline process solutions for gold mining
Anton Paar Flow Measurement & Control
[Sponsored]The extraction and processing of gold ore requires precision and efficiency to maximise yield and minimise losses. Automation and continuous monitoring of critical process steps are essential to ensure optimal production. Anton Paar offers advanced inline measurement solutions which enable full automation and real-time monitoring of key steps in gold extraction and processing.

Read more...
Magnetic-inductive flow sensor
ifm - South Africa Flow Measurement & Control
The SMF magnetic-inductive flow sensor revolutionises liquid and creamy flow measurement. With IO-Link, it enables digital data transmission, eliminating blind spots in production.

Read more...
Hygienic flow measurement for the food industry
ifm - South Africa Flow Measurement & Control
With the SMF magnetic-inductive flow meter, ifm offers a solution for the hygienic flow measurement of media with variable flow rates through a pipe, such as beer, milk or fruit juice.

Read more...









While every effort has been made to ensure the accuracy of the information contained herein, the publisher and its agents cannot be held responsible for any errors contained, or any loss incurred as a result. Articles published do not necessarily reflect the views of the publishers. The editor reserves the right to alter or cut copy. Articles submitted are deemed to have been cleared for publication. Advertisements and company contact details are published as provided by the advertiser. Technews Publishing (Pty) Ltd cannot be held responsible for the accuracy or veracity of supplied material.




© Technews Publishing (Pty) Ltd | All Rights Reserved