Flow Measurement & Control


Intelligent and durable electromagnetic flowmeters

April 2001 Flow Measurement & Control

Electromagnetic flowmeters use Faraday's principle of electromagnetic induction to measure the flow of conductive fluids. Toshiba has been marketing electromagnetic flowmeters since the late 1960s and as a result of a wealth of experience and considerable engineering expertise, have won accolades in all areas of industry.

A full line-up of products covering diameters from 2,5 mm to 3 m as well as various liner materials to accommodate diverse applications, making possible fluid measurements in almost any imaginable application.

Main applications

* Water and waste.

* Food, beverage and pharmaceutical.

* Liquids containing solid matter: concrete slurries; mortar.

* Steel, nonferrous metals: cooling water; metals processing; fertilisers and inorganic chemicals; aqueous acid/alkaline solutions.

* Pulp and paper: paper-making processes; pulp; polymer chemicals; chemical fibres.

LF400 and LF420 converters are provided with universal power supplies as standard equipment, enabling use anywhere in the world. They can be powered at 100 to 240 V a.c.; 24 V and 110 V d.c. power supplies are also available.

Enhanced resistance to harsh environments

* Ceramic measurement tubes improve resilience. The LF470 and LF410 detectors (2,5 to 100 mm) employ an alumina ceramic measurement tube, for improved resistance to abrasion, pressure and temperature. The ceramic measurement tube is surrounded by metal in a construction impervious to stresses in pipe installation and stresses caused by rapid changes in temperature.

* EPDM lining to improve ozone confinement. The EPDM lining material provides excellent ozone resistance, so that flowmeters can be used without hesitation in high-grade water treatment and other plants where ozone resistance is important.

Further improvements to the functional magnetic field distribution method have made possible accurate measurements of flow rates in partially filled pipes, beyond the capabilities of ordinary electromagnetic flowmeters.

Model LF490 is used for the measurement of flow under sanitary conditions. The flowmeters are designed with quick connect components for clean, easy handling.

TM Automation

(011) 867 2737

[email protected]





Share this article:
Share via emailShare via LinkedInPrint this page

Further reading:

Mastering inline LNG flow monitoring
Flow Measurement & Control
[Sponsored] As global demand for cleaner, more flexible energy sources continues to rise, liquefied natural gas (LNG) stands at the forefront of the energy transition. Engineered for excellence in cryogenic environments, the Anton Paar L-Cor 8000 flowmeter redefines inline LNG flow monitoring.

Read more...
Magnetic-inductive flowmeter with effective compact electronics and IO-link
Instrotech Flow Measurement & Control
KOBOLD has combined two of its proven components, the successful type MIK magnetic-inductive flow meter and the popular U-PACE compact electronics, creating an exciting new compact flow instrument at the best price.

Read more...
Dosing chlorine gas safely and sustainably
Flow Measurement & Control
Chlorine gas is central to a range of industrial processes but is highly dangerous. The solution is the deployment of a system solution for chlorination from Lutz-Jesco.

Read more...
Oil monitoring solution drives performance gains for paper mill
SKF South Africa Flow Measurement & Control
By integrating real-time monitoring with precise flow control, SKF’s Flowline oil monitor meters have significantly improved the flow rate control and performance of oil circulation lubrication systems installed on a paper mill.

Read more...
Flow measurement in mobile applications
ifm - South Africa Flow Measurement & Control
The SU Puresonic Mobile ultrasonic sensor from ifm is characterised by its displayless design and high temperature resistance. It is ideal for mobile applications and processes with permanent media temperatures of up to 120°C.

Read more...
Optimising water quality in a building cooling system
ifm - South Africa Flow Measurement & Control
A leading company in industrial water management has installed water treatment systems that not only optimise water quality but also help customers to improve their processes, thanks to the new insights and actions that can be generated based on the process data collected.

Read more...
New uncompromisingly simple flowmeter line for processes
Endress+Hauser South Africa Flow Measurement & Control
The demand for simplicity in commissioning, operation and maintenance in industrial process plants has increased significantly in recent years. The new Proline 10 range of flowmeters from Endress+Hauser meets this requirement without compromise, because simplicity is the top priority.

Read more...
Rotork joins Rockwell Automation’s Technology Partner Programme
Flow Measurement & Control
Rotork has entered into the Rockwell Automation Technology Partner Programme, marking a significant step in expanding the company’s presence within the industrial automation landscape.

Read more...
Loop signature 29: Averaging or surge level control
Editor's Choice Flow Measurement & Control
There are many processes where it is undesirable for the load to suddenly change quickly, for example in the paper industry. Examples of level control have involved reasonably fast tuning. An example of a level loop tuned this way and responding to a step change in setpoint is given.

Read more...
A reliable water supply: The make or break in building metros across South Africa
VEGA Controls SA Flow Measurement & Control
South Africa’s urban centres encounter substantial water supply challenges. Maintaining stable water infrastructure is essential for the health, economic vitality and well-being of communities.

Read more...









While every effort has been made to ensure the accuracy of the information contained herein, the publisher and its agents cannot be held responsible for any errors contained, or any loss incurred as a result. Articles published do not necessarily reflect the views of the publishers. The editor reserves the right to alter or cut copy. Articles submitted are deemed to have been cleared for publication. Advertisements and company contact details are published as provided by the advertiser. Technews Publishing (Pty) Ltd cannot be held responsible for the accuracy or veracity of supplied material.




© Technews Publishing (Pty) Ltd | All Rights Reserved